Fisher Scientific™ accumet™ AB200 pH/Conductivity Benchtop Meters Available on GSA/VA Contract for Federal Government customers only.

Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisher Scientific accumet AB200 pH/conductivity meter combines the benefits of a pH meter and conductivity meter in one easy to use, reliable measurement system. The large backlit display offers great visibility in laboratory environments.

 View more versions of this product

Catalog No. 13-636-AB200

  Check Availability
Add to Cart

Includes: accumet AB200 pH benchtop meter, TRIS-compatible double junction refillable epoxy-body pH/ATC electrode (13-620-631), conductivity/temperature probe (13-620-100), electrode stand, RS232 and USB cables, 100/240V universal power supply

    Specifications

    Hertz 50/60Hz
    Accuracy (TDS) ±1 % full scale
    Accuracy (Salinity) ±1 % full scale
    Accuracy (Resistivity) ±1 % full scale
    Certifications/Compliance Without NIST-traceable pH Certificate
    Warranty 3 Years
    Accuracy (Conductivity) ±1% FS
    Data Management Details Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format
    Model AB200 pH/Conductivity Kit
    Voltage 100/240V
    Resolution (Conductivity) 0.01/0.1μS, 0.001/0.01/0.1mS
    Range (TDS) 0ppm to 500ppt (at TDS factor 1)
    Resolution (TDS) 0/0.1ppm, 001/01/0.1ppt
    Resolution (Salinity) 0.01/0.1ppm, 0.001/0.01/0.1ppt
    Includes Meter, TRIS Compatible pH/ATC Electrode (13-620-631), Conductivity/Temp Probe (13-620-100), Electrode Arm, RS-232 and USB cables, 100/240V Power Supply
    Range (Resistivity) 2W to 20MW
    Resolution (Resistivity) 0.01/0.1W, 0.001/0.1kW, 0.01MW
    Cell Constant 0.010 to 10.000
    Resolution (pH) 0.1/0.01/0.001
    Calibration Points (pH) Up to 6 pre-set or 5 custom
    Calibration Points (Conductivity) Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range
    Resolution (Temperature) 0.1°C
    Display Type LCD
    Outputs RS232 (phono plug), mini-B USB, stirrer
    Resolution (mV) 0.1mV
    Accuracy (mV) ±0.2mV
    Range (Conductivity) 0μS to 500mS
    Range (Salinity) 0 to 80ppt
    Range (pH) -2 to 20
    Accuracy (pH) ±0.002
    Accuracy (Temperature) ±0.3°C
    Range (mV) ±2000mV
    Data Points 500
    Inputs BNC, ATC

    • Graphic backlit display with date and time, stability indicator and alarms
    • Dual channel meter for pH and conductivity measurements
    • One to six point pH calibration with 0.001 pH resolution
    • Automatic buffer recognition with four pH buffer sets or custom buffer option
    • pH slope and offset display
    • Conductivity, TDS (total dissolved solids), salinity and resistivity modes
    • Automatic or manual temperature compensation, displayed in °C or °F
    • Password protection of calibration and setup modes
    • 500 data set storage
    • RS232 and USB interfaces
    • Multilanguage interface with English, German, Chinese, French, Italian and Spanish
    • Optional stirring probe (Cat. No. 13-620-BSP) with five speed settings
    NIST-Traceable Calibration Model (-CERT)
    • Help meet ISO, FDA, USDA and EPA quality assurance guidelines
    • Includes meter accuracy at five test points across pH range
    • Includes meter accuracy at five test points across corresponding mV range
    • Testing performed by accredited laboratory, includes NIST-Traceable certificate
    Specifications
    pH Range: -2.000 to 20.000 pH
    pH Resolution: 0.1, 0.01, 0.001 pH
    pH Accuracy: ±0.002 pH
    mV Range: ±2000.0mV
    mV Resolution: 0.1mV
    mV Accuracy: ±0.2mV or ±0.05 %, whichever is greater
    mV Offset Adjustment: Up to ±150mV
    Conductivity Range: 0.00µS to 500.0mS
    Conductivity Resolution: 0.01, 0.1µS; 0.001, 0.01, 0.1mS
    Conductivity Accuracy: ±1 % full scale
    TDS Range: 0.00ppm to 500 ppt (TDS factor 1.00)
    TDS Resolution: 0.01, 0.1 ppm; 0.001, 0.01, 0.1 ppt
    TDS Accuracy: ±1 % full scale
    Salinity Range: 0 to 80.0 ppt
    Salinity Resolution: 0.01, 0.1 ppm; 0.001, 0.01, 0.1 ppt
    Salinity Accuracy: ±1 % full scale
    Resistivity Range: 2.000 Ohm to 20.0 MOhm
    Resistivity Resolution: 0.01, 0.1 Ohm; 0.001, 0.1 kOhm; 0.01 MOhm
    Resistivity Accuracy: ±1 % full scale
    Temperature Range: 0° to 100°C (32° to 212.0°F)
    Temperature Resolution: 0.1°C (0.1°F)
    Temperature Accuracy: ±0.3°C (±0.5°F)
    Calibration Points: 1 to 6 points with automatic buffer recognition (ABR)
    ATC Temperature Calibration: Offset in 0.1°C increments; Offset range: ±5°C (±9°F)
    Self-Test: Yes
    Inputs: BNC, mini-phone ATC, 8 Pin DIN, ground
    Power Requirements: 100 to 240VAC, 50/60Hz
    Applications
    Academic, research, QA/QC, drinking water, wastewater, food, beverage, industrial

    Certifications

    CE, TUV 3-1, FCC Class A

    Warranty

    3 years on meter