Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

GE Healthcare HiScreen™ Capto™ Phenyl (High Sub) Prepacked HIC Column

Hydrophobic interaction chromatography (HIC) media used in the capture and intermediate stages of protein purification, used for method optimization and parameter screening

Manufacturer:  GE Healthcare 28992472

Catalog No. 45-002-549


Add to cart

Description

Description

  • Highly cross-linked agarose matrix with average bead size of 75µm
  • Has good flow properties and high loading capacities
  • Bed height of 10cm designed to allow method optimization and parameter screening
  • Connect easily in series to achieve 20cm bed height
  • Small bed volume gives fast results and minimal sample/buffer consumption
  • Capto Phenyl (high sub) media is used for initial and intermediate step purifications requiring a chromatography medium with medium to high hydrophobicity
  • Combines high capacity with high flow velocity and low backpressure to reduce process cycle times and increase productivity
  • Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity

  • Bed volume: 4.7mL
  • Bed dimension: 7.7 x 100mm
  • Flow rate: 1.2 to 2.7mL/min.
  • Flow velocity: <600cm/hr.
Media
  • Average particle size: 75µm
  • Degree of substitution: 27µmol/mL gel
  • pH stability cleaning: 2 to 14
  • Pressure/Flow specification: 300kPa at 600cm/hr., 1m diameter column, 20cm bed height
  • Medium: BioProcess
  • pH stability working range: 3 to 13
  • Ligand: phenyl
  • Binding capacity/mL chromatography medium: 27mg BSA /mL (at QB10%)
Column
  • Bed support: filter
  • Material (column hardware and column tube): polypropylene
  • Column I.D.: 7.7mm

Specifications

Specifications

Aqueous Buffer
0.3 in.
HiScreen Capto Phenyl (high sub) column
Optimization and parameter screening
100mm
Polypropylene
43.5psi
75μm
4° to 30°C
4.7mL
7.7mm
1 x 4.7mL
3.93 in.
<600cm/hr.
Phenyl (∼27μM/mL drained medium)
3 to 13
Highly Cross-linked Agarose
Documents
Provide Content Correction

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit