Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

Invitrogen™ GeneArt™ Site-Directed Mutagenesis PLUS System

Catalog No. A14604
Encompass_Preferred
Change view
Click to view available options
Quantity:
10 Reactions
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Catalog No. Quantity
A14604 10 Reactions
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Catalog No. A14604 Supplier Invitrogen™ Supplier No. A14604
  • $648.00
    $615.65 / Each of 1

    Save $32.35

    5% Off The following deviations and disclosures may produce prices below stated discounts but will not trigger price reductions: Price shown reflects a temporary, promotional price reduction. No other purchase or commercial obligation required to receive the reduced price. Price may change at any time. Promotional price valid on web orders only. Your contract pricing may differ. Other exclusions apply.
Add to Cart
Add to Cart

missing translation for 'validMainframeMsg'

Brings our mutagenesis technology to the next level with the ability to perform single- or multi-site mutations in larger plasmids with greater efficiency and in less time than the competition

Features:
  • Powerful—make substitutions, deletions, or insertions of up to 3 nucleotides in 1, 2, or 3 separate sites in DNA plasmids of up to 14kb
  • Flexible—perform multi-site mutagenesis with degenerated nucleotides and single-site mutations up to 25 nucleotides long or 12 nucleotides long with degenerated nucleotides
  • Efficient—obtain your desired mutants the first time; over 90% correct mutants in a 10kb plasmid
  • Fast—obtain your mutated plasmid DNA in typically less than 3 hours with the simple, minimal-handling protocol
  • Versatile—use plasmids of many sizes, and DNA isolated from any source, with no need for specialized vectors, host strains, or restriction sites

Optimized Mutagenesis Protocol
The GeneArt™ Site-Directed Mutagenesis System was further optimized for efficiency and multi-site capability, resulting in the “PLUS” kit. Like the first generation GeneArt™ Site-Directed Mutagenesis System, DNA methylation and amplification steps are combined into a single reaction, with no need for an in vitro DpnI digestion step. After methylation and amplification, a 15 minute in vitro recombination reaction of the amplified PCR products increases the colony output by 3 to 10 fold, resulting in a higher mutagenesis efficiency. A final transformation of the mutated DNA into DH5α™ E.coli cells digests any methylated parental DNA, leaving behind only the intact unmethylated mutagenesis reaction product. No purification steps or additional digestions are needed. Individual colonies can be selected the following day to verify mutations.

Simple Creation of Desired Mutants
Creating mutants with the GeneArt™ Site-Directed Mutagenesis PLUS System relies on the inherent properties of DNA methylase, high fidelity DNA polymerase, recombination enzymes, and the native McrBC endonuclease of E. coli. Simply incorporate your desired mutation or mutations into primers using our GeneArt™ Design Tool for Seamless Assembly and Mutagenesis (see “in silico Design Support”, below). Combine the vector and mutagenesis primers, and after PCR, recombination, and transformation you will have vectors with only the desired mutations with over 90% efficiency.

in silico Design Support
A key step in GeneArt™ site-directed mutagenesis is the correct design of primers with the appropriate homology and spacing to help ensure successful mutagenesis of your plasmid. To simplify and speed the design process, we provide a free online tool, the GeneArt™ Design Tool for Seamless or High-Order Assembly and Mutagenesis, to help you design your experiment in silico. The tool allows you to review your plasmid sequence, designs DNA oligos for introduction of the desired mutations, provides an updated amino acid sequence for your mutated gene, displays a graphical representation of the new construct, and enables the download of an annotated sequence in GenBank format that is compatible with Vector NTI™ software.

For Research Use Only. Not intended for human or animal therapeutic or diagnostic use.

TRUSTED_SUSTAINABILITY

Specifications

Bacterial or Yeast Strain DH5α
Cell Type Chemically Competent E. coli
Content And Storage • GeneArt 2X Enzyme Mix (12 μL)
• One Shot MAX Efficiency DH5α-T1R (1 box)
• DNA Methylase (12 μL)
• 200X SAM (10 μL)
• 10X PCR Enhancer (100 μL)
• PCR Water (1.8 μL)
• pMSDM-White Vector (5 μL)
• Control Primer Mix 1, 2, & 3 (20 μL each)
• 0.5 M EDTA (500 μL)

For convenience, all contents may be stored at −80°C.
Efficiency 90 %
For Use With (Application) Seamless Cloning & Genetic Assembly
Mutagenesis Capability Mutagenesis at Multiple Sites
Mutagenized Region Length (up to) 3 nucleotides (multi-site), 25 nucleotides (single-site)
Mutation Type Deletions, Insertions, Substitutions
Plasmid Plasmids up to 14 kb
Product Type Site-Directed Mutagenesis PLUS System
Quantity 10 Reactions
Show More Show Less
Is the DNA methylase from GeneArt Site-Directed Mutagenesis kits available separately?

We do not offer the DNA methylase from GeneArt Site-Directed Mutagenesis kits as a separate product.

How does PCR with two overlapping primers result in a final product with homology at both ends?

During the first cycle of PCR on the circular template, the polymerase will generate two linear products that are able to anneal and undergo primer extension in the next cycle. PCR products that incorporate the mutation at both ends will accumulate in subsequent cycles. After PCR, the recombination reaction results in circularization of the PCR product which enhances the mutagenesis efficiency.

What is the difference between the GeneArt Site-Directed Mutagenesis PLUS Kit and the GeneArt Site-Directed Mutagenesis System?

The kits are almost the same, but the PLUS kit contains an improved 2X GeneArt enzyme mix with protocols optimized for multi-site mutagenesis (up to 3 sites in plasmids up to 14 kb). The PLUS kit can also be used for single-site mutations of up to 25 nucleotides, while the original kit can be used for single substitution/deletion/insertions up to 12 nucleotides in plasmids up to 14 kb. A web tool is available for primer design that can also be used for the original kit.

I'd like to have site-directed mutagenesis performed as a service by GeneArt off of my own plasmid. Can this be done?

Yes. Add “single variant” as a new process, then choose an “upstream service” which is: gene synthesis, already at Geneart, or I will provide this master gene. If the customer is providing their own gene, they will need to fill in the field for the complete sequence of their vector + insert. If it is a plasmid only, they will put the mutagenized area as the “insert” and the rest of the plasmid as the “vector”. The “insert” can only be up to 4kb long.

Do I have to make a fresh dilution of 25X SAM each time I perform my GeneArt Site Directed Mutagenesis procedure?

Yes, 25X SAM is not stable and will lose activity within a few hours. We recommend creating a new dilution of SAM from the 200X SAM supplied in the kit each time you perform a mutagenesis procedure.

What polymerase do you recommend using with the GeneArt Site-Directed Mutagenesis and GeneArt Site-Directed Mutagenesis PLUS systems?

We recommend using AccuPrime Pfx DNA Polymerase with the GeneArt Site-Directed Mutagenesis kits.

What is the difference between the GeneArt Site-Directed Mutagenesis and GeneArt Site-Directed Mutagenesis PLUS kits?

The kits are almost the same, but the PLUS kit contains an improved 2X GeneArt enzyme mix with protocols optimized for multi-site mutagenesis (up to 3 sites). A web tool was also introduced for primer design, but this can also be used for the original kit.

Do you offer a kit for site-directed mutagenesis?

Yes, we offer three kits for site-directed mutagenesis: GeneArt Site-Directed Mutagenesis System and GeneArt Site-Directed Mutagenesis PLUS kit, Phusion Site-Directed Mutagenesis Kit as well as a custom GeneArt service.

The kits are almost identical, but the PLUS kit contains an improved 2x GeneArt Enzyme mix with protocols optimized for multi-site mutagenesis (up to 3 sites in plasmids up to 14 kb). The PLUS kit can also be used for single-site mutations of up to 25 nucleotides, and the original kit can be used for single substitution/deletion/insertions up to 12 nucleotides in plasmids up to 14 kb. A web tool was also introduced for primer design, but this can also be used for the original kit. Phusion Site-Directed Mutagenesis Kit is a versatile and efficient tool for introducing point mutations, insertions, or deletions in any type of plasmid DNA. With this kit, the entire plasmid is amplified using phosphorylated primers that introduce the desired changes. The amplified, linear PCR product, containing the desired mutation, is circularized in a 5-minute ligation reaction with T4 DNA Ligase. The resulting plasmid can be then transformed into any competent E. coli cells.

After a PCR mutagenesis protocol, how is the plasmid repaired after it is transformed into E. coli?

The detailed mechanism is still not very clear, but involves the E. coli double strand break repair system. The key steps are:

(1) An exonuclease, like RecBCD, removes nucleotides from the ends to generate a single-stranded region.

(2) Strand invasion with homologous regions occurs.

(3) Repair enzymes including nucleases, ligase, and DNA polymerases repair gaps and/or nicks.

What is the concentration of the 200X SAM included in the GeneArt Site-Directed Mutagenesis PLUS System?

The concentration of the 200X SAM, included in the GeneArt Site-Directed Mutagenesis PLUS System, is 32 mM.

I'm getting high background when testing my mutagenesis reaction product. What should I do?

Please see the typical causes and solutions for this problem below:

-Inactive DNA methylase or inactive SAM: Test the activity of the DNA methylase and 25X SAM using the methylation control reaction.
-Too much DNA used: Use no more than 50 ng of DNA per 50 µL of methylation reaction.
-Over-amplification: Reduce PCR cycles to 12 for small plasmids or 15 for intermediate size plasmids.

I'm performing site-directed mutagenesis and am not seeing a visible PCR product. What should I do?

Please see the typical causes and solutions for this problem below:

-Too little DNA: use up to 50 ng DNA per 50 µL reaction.
-Poor quality DNA: purify new plasmid.
-Incorrect DNA polymerase used: We recommend using 1 unit of AccuPrime Pfx DNA Polymerase for amplification.
-PCR conditions were incorrect: Optimize annealing temp and extension time.
-Poor primer design: Use the GeneArt Primer and Construct Design Tool to reduce potential secondary structures or increase primer length

I followed the recommended PCR conditions for my site-directed mutagenesis studies but am not getting a product. What should I do?

Please review the following recommendations:

-What polymerase are you using? We recommend using AccuPrime Pfx DNA polymerase with both mutagenesis kits - use 1 unit of the polymerase for amplification.
-Try optimizing the annealing temperature and extension time. The rule of thumb is 5-10 degrees C below your primer's lowest melting temperature for the annealing temperature, and 30 seconds per 1kb for extension time. You can experiment with different temperatures/times to optimize your reaction.
-Poor primer design could result in no product. We recommend using our tool to reduce potential secondary structures or increase the primer length.
-Check the quality of your starting DNA sample.
-Ensure that you are adding enough DNA to the PCR reaction