Labconco™ Protector™ Controlled Atmosphere Glove Boxes

Glove boxes provide a leak-tight environment for work with contamination-sensitive materials

Manufacturer: Labconco™ 5080135

 View more versions of this product

Catalog No. 16-200-438

  Check Availability

This item is a non-standard voltage; please ensure you are ordering the correct product.

Please contact customer service for assistance: 1-800-766-7000.

Add to Cart

Required Accessories : Supporting base, vacuum pump for evacuating, inert gas for filling.

    Specifications

    Liner Material Stainless Steel
    Voltage 208/230V
    Certifications/Compliance UL, ETL, CAN/CSA
    Amperage 10A
    Depth (Metric) Exterior 87.4cm
    Depth (English) Exterior 34.4 in.
    Type Glove Box
    Height (English) Exterior 45.7 in.
    Width (English) Exterior 63.5 in.
    Display LCD
    For Use With (Application) Controlled atmosphere sensitive materials
    For Use With (Equipment) AtmosPure™ Re-Gen gas purifier
    Height (Metric) Exterior 116.1cm
    Lighting Two 25w fluorescent
    Plug Type Schuko Plug
    Ports 2
    Width (English) Interior 35 in.
    Weight (Metric) 295kg
    Weight (English) 650 lb.
    Width (Metric) Exterior 161.3cm
    Width (Metric) Interior 88.9cm
    Warranty 1 Year

    Key Features

    • Exceed Class 1 atmosphere containment conditions for oxygen permeation <1.67 ppm/min. per ISO 10648-2 test method
    • Four manual valves with 3/8 in. compression fittings—two on the main chamber and two on the transfer chamber
    • Automatic control of the main chamber pressure, main chamber evacuation and filling cycles, and transfer chamber evacuation and filling cycles
    • Regulation of vacuum/pressure between -5 and +5 inches of water gauge in the main chamber and between 0 and -29.5 inches of mercury in the transfer chamber
    • Mutable, audible/visual alarm that sounds when pressure/vacuum level is outside set limits
    • Three-position foot pedal (increase gas/fill, off, evacuate/decrease gas)
    • Factory-installed, rear-mounted, low profile stainless steel pressure relief bubbler at ±6 inches of water gauge
    • Two rear-mounted inlet and outlet 3/4 in. OD compression fittings for easy connection to optional gas purifier or accessory drying train
    • Factory leak-tested—no detectable leaks greater than 1 x 10-6mL/sec.

    Additional Features

    • LCD display of main chamber and transfer chamber pressure in inches of water, inches of mercury and mBar
    • 0.38 in. thick laminated safety glass viewing window with 36.0W x 27.6 in.H (91 x 70cm) viewing area
    • Pair of neoprene gloves 0.015 in. thick, 30 in. long, size 9 3/4
    • Two 8 in. ID epoxy-coated aluminum, double-grooved glove ports with neoprene gaskets
    • Switches for light and electrical receptacle
    • Two 25-watt fluorescent lights
    • Dry-powder epoxy-coated, 18 and 20 gauge steel exterior panels

    Stainless Steel-lined Model Features

    • Type 304 stainless steel liner with Type 304 stainless steel inner and outer transfer chamber doors; Type 304 stainless steel front panel
    • Performance tested to maintain oxygen levels as low as 0.2 ppm and moisture levels as low as 1 ppm
    • Oxygen permeation <0.16 ppm/min per ISO 10648-2
    Fiberglass-lined Model Features
    • One-piece molded fiberglass liner with clear acrylic inner and outer transfer chamber doors
    • Performance tested to maintain oxygen levels as low as 0.4 ppm and moisture levels as low as 2 ppm
    • Oxygen permeation <0.3 ppm/min per ISO 10648-2

  • Description & Specifications

Related Products


Product Content Feedback

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit