Labconco™ Protector™ XStream™ High Performance By-Pass Hoods: 5ft. Width, 115V

Offering unsurpassed containment of chemical fumes and vapors while conserving energy when operated at velocities as low as 60 fpm, the Labconco Protector™ XStream™ High Performance By-Pass Hood provides your workers with extra safety in the lab.

Manufacturer: Labconco™ 110510000

 View all options for this product

Catalog No. 10-369-104

  Check Availability
Add to Cart

Required Accessories : Remote Blower, Ductwork, Work Surface, Base Cabinet or Stand


    Depth (English) 37.7 in.
    Depth (Metric) 95.8cm
    Height Overall (English) 59 in.
    Height Overall (Metric) 149.9cm
    Width (English) 60 in.
    Width (Metric) 152.4cm
    Construction Powder coated steel
    Sash Opening (English) 18 in.
    Voltage 100/115V
    Flow Rate 580 cfm
    Weight (English) 525 lb.
    Weight (Metric) 238kg
    Amperage 10A
    Certifications/Compliance ANSI Z9.5, ASHRAE 110, ASTM E84, CAN/CSA C22.2, NFPA 45, SEFA 1, UL
    Color Glacier White
    Includes No Service
    Lighting T8 fluorescent

    Design negates the effects of air turbulence, vortexing, and interior air “roll”.

    • Largest unobstructed sight line available — 37.5 in. from work surface to header panel — provides maximum visibility and user comfort
    • Ergonomic Eco-Foil air foil that reduces energy consumption from 7-10%
    • Clean-Sweep Sash Handle slots bleed air into the hood chamber and directs fume concentrations away from breathing zone
    • Opti-Zone Baffle decreases typical face velocity variations found with other baffles
    • Dry powder-coated steel exterior
    • Upper Dilution Air Supply bathes the sash interior with room air to eliminate chemical fumes along the sash plane near breathing zone
    • Pre-set rear downflow dual baffle
    • Pre-wired T8 fluorescent lighting
    • Sash stop located at 18 in. sash opening position
    • Pre-drilled holes for venting and plumbing passthroughs are provided

    • Pre-wired T8 fluorescent lighting
    • Sash stop located at 18 in. sash opening position
    • 12.81 in. ID exhaust connection(s)
    • Corresponding SpillStopper™ (sold separately) are molded from a special formulation of corrosion-resistant epoxy resin and are dished and contoured to conform to the interior liner of hood
    • Front edge has a large radius to aerodynamically direct airflow into the fume hood
    • Pre-drilled holes for venting and plumbing passthroughs are provided

    115V models are ETL listed.

  • Description & Specifications

Related Products

Product Content Feedback

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit