Labconco™ Purifier™ HEPA-Filtered Safety Enclosures with Guardian Monitor

Labconco Purifier™ HEPA-Filtered Safety Enclosures with Guardian Monitor provide personnel and environmental biohazard protection.

Manufacturer: Labconco™ 3980222

 View all options for this product

Catalog No. 10-304-125

  Check Availability

This item is a non-standard voltage; please ensure you are ordering the correct product.

Please contact customer service for assistance: 1-800-766-7000.

Add to Cart


    Amperage 2A
    Height (English) 37.08 in.
    Sash Opening (Metric) 23.97cm
    Type Enclosure
    Electrical Requirements 230V 50/60Hz
    Filter Type HEPA
    Hertz 50/60Hz
    Housing Material Epoxy Coated Aluminum and Steel
    Lighting Fluorescent
    Voltage 230V
    Volume 110 to 155 cfm
    Weight (English) 125 lb.
    Weight (Metric) 57kg
    Width (English) 23.75 in.
    Width (Metric) 60.32cm

    Meet requirements for Biosafety Level 1, 2, or 3 containment without product protection, making these an economical alternative to Class II biosafety cabinets. Also suitable for chemical and particulate powder weighing and other procedures generating fine dusts or aerosols. HEPA-filtered enclosures require no outside exhausting.

    • Total exhaust from 155 to 310cfm, depending on hood width
    • Sash pivots 10°, from 9.5 in. (24cm) operating position to 20 in. (50.8cm) opening for loading and maintenance
    • Quiet variable-speed, solid-state internal blower maintains appropriate air velocity
    • Airfoil with Clean-Sweep™ airflow openings
    • Built-in Guardian™ Airflow Monitor to alert user of face velocities outside preset range (where applicable)
    • Front-mounted pressure gauge monitors pressure differential against the HEPA filter
    • HEPA filter is 99.99% efficient on 0.3µm particles (where applicable)
    • Negative pressure design ensures containment—should a leak occur, the system traps the contaminated air and recirculates it through the filter
    • Class I Enclosures have a 15w, 254nm germicidal UV lamp to use in conjunction with surface disinfection to ensure decontamination of biohazardous particulates while unattended

    • 0.25 in. (6.4mm) Tempered glass side panels and sash
    • Glare-free fluorescent lamp mounted outside contamination area
    • Blower and light switches are front-mounted for easy access
    • Powder-coated aluminum frame and steel rear plenum and zone-perforated rear baffle
    • Back panel has two utility ports for service connections
    • Open bottom allows enclosure to be placed on existing cabinetry or accessory dished work surface

    For operator safety, UV lamp cannot be turned on when fluorescent lamp is in use.