Thermo Scientific™ MIRAN SapphIRe Portable Ambient Analyzers

Accurately measure a variety of gases with a single instrument using Thermo Scientific™ MIRAN SapphIRe Portable Ambient Analyzers.

 View all options for this product

Catalog No. 19-171-043

  Check Availability
Add to Cart


    Computer Requirements Windows-based graphical user interface
    Description 50 single-gas applications; Single battery charger
    Display Type 8 lines 40 character LCD
    Flow Rate 14L/min.
    Height (English) 14.4 in.
    Height (Metric) 365mm
    Depth (English) 7.6 in.
    Depth (Metric) 193mm
    Outputs 0 to 1VDC, Parallel, Serial
    Weight (English) 24 lb.
    Weight (Metric) 10kg
    Width (English) 21.8 in.
    Width (Metric) 553mm
    Alarms User definable
    Analysis Time Single wavelength, 20 sec.; 5 wavelengths, 50 sec.; spectral scan, 165 sec.
    Battery Life 4 hr.
    Battery Type Internal, Rechargeable NiCd. 7.2V nominal; 5.7 Ah capacity
    Detector Type Single beam infrared spectrophotometer
    Item Description SL Model; 50 single-gas applications
    Optics Linear Variable Filter (LVF) from 7.7 to 14.1; seven fixed band pass filters 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7
    Pathlength 0.5 or 12.5M
    Response Time 18 sec. to 90% of final reading
    Sample Cell Volume 2.23L
    Certifications/Compliance User-specified models are certified for: ETL (Class 1, Div. 1 Groups B, C and D Temp Class T4)ETL-C (Class1, Div. 1 Groups B, C and D Temp Class T4). CE marked

    Accurately measure a variety of gases with a single instrument using Thermo Scientific™ MIRAN SapphIRe Portable Ambient Analyzers.
    These analyzers utiize infrared spectroscopy for wavelength coverage that permits outstanding single and multi-gas monitoring as well as unknown compound identification, making the MIRAN SapphIRe one of the most versatile gas detection system on the market today. In addition, non-destructive infrared technology means you can send field-analyzed samples to a laboratory for further analysis.

    The wavelength generator filter has a unique design that allows rapid, accurate wavelength selection, separating it from other gas analyzers.

    Key Features:

    • Easy to use
    • Selective
    • Sensitive enough for sub-ppm detection
    • Can be upgraded
    All models include:
    • User-defined library space for 10 single-gas and 10 multi-gas applications
    • Real-time compensations for temperature, humidity, reference, and pressure
    • Optics: Linear Variable Filter (LVF) from 7.7 to 14.1; seven fixed band pass filters 1.8, 3.3, 3.6, 4.0, 4.2, 4.5 and 4.7
    • Pathlength: 0.5M or 12.5M

    Optional ThermoMatch Spectrum Correlation Software:

    • Helps identify unknown airborne compounds
    • Includes 150 common toxic industrial compounds, and can be modified to incorporate a user library of hundreds more
    • Permits industrial users to include all site-specific compounds, increasing the quality of results
    • Allows first responders to include SARA Tier II compounds for critical facilities to aid in containment actions
    • Offers optimum speed of analysis with on-the-spot correlation of unknown compounds; onsite results eliminate need for costly and time-consuming lab analysis of potentially blank samples
    • Saves spectra absorption files with data logging for further analysis and record keeping

    ThermoConnect Software

    The included Windows™-based graphical user interface enables users of the MIRAN SapphIRe to transfer, display, analyze and configure data from instrument using a computer.

    MIRAN SapphIRe XL

    • Offers optimal measurement capabilities for high-end users who need to measure a wide variety of a mixed atmosphere of gases
    • Contains over 120 single-gas applications with customization capabilities
    • Ideal for consultants, industrial hygienists, regulatory agencies, research scientists and emergency response professionals

    MIRAN SapphIRe SL

    • Provides flexibility for users who perform similar measurements on a routine basis
    • Contains over 50 single-gas applications with customization capability
    • Popular with indoor air quality specialists and anesthetic gas monitoring technicians

    MIRAN SapphIRe DL

    • Designed for users who regularly encounter a limited number of air monitoring applications
    • Features quick and easy operation for enforcement agencies and specified compound measurement projects

    Recommended for:

    • Industrial hygiene
    • Emergency response analysis
    • Indoor air quality studies
    • Waste anesthetic gases
    • Fume hood/tracer gas analysis
    • Leak detection for process maintenance

  • Description & Specifications
  • Accessories

Related Products

Product Content Feedback

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit