    Description Orion Star A215 pH/conductivity benchtop meter kit with ROSS Ultra Triode epoxy-body pH/ATC electrode, DuraProbe 4-cell conductivity sensor, solutions and stand
    Item Description Orion Star A215 pH/conductivity benchtop meter kit with ROSS Ultra Triode epoxy-body pH/ATC electrode, DuraProbe 4-cell conductivity sensor, solutions and stand
    Range (pH) -2.000 to 20.000pH
    Resolution (pH) 0.1, 0.01, 0.001pH
    Accuracy (pH) ±0.002pH
    Range (mV) ±2000.0mV
    Range (Relative mV) ±2000.0mV
    Range (ORP) ±2000.0mV
    Resolution (mV) 0.1mV
    Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
    Isopotential Point 7.000pH
    Range (Conductivity) 0.001 µS/cm to 3000 mS/cm
    Resolution (Conductivity) 0.001 μS minimum, auto ranging up to 4 significant digits
    Accuracy (Conductivity) 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS
    Range (TDS) 0.001 to 200.0 ppm
    Resolution (TDS) 0.001 ppm minimum, auto ranging up to 4 significant digits
    Accuracy (TDS) 0.5% of reading ±1 digit
    TDS Factor Range Linear (0.02 to 9.99)
    Range (Salinity) 0.06 to 80.00 psu, 0.05 to 42.00 ppt
    Resolution (Salinity) 0.01 psu or 0.01 ppt minimum, auto ranging
    Accuracy (Salinity) 0.5% of reading ±1 digit
    Salinity Measurement Modes Practical salinity (psu) or natural sea water (ppt)
    Range (Resistivity) 2 ohm to 100.0 meg-ohm
    Resolution (Resistivity) 1 ohm or 0.1 meg-ohm, auto ranging
    Accuracy (Resistivity) 0.5% of reading ±1 digit
    Cell Constant 0.001 to 199.9cm-1
    Temperature Compensation Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
    Temperature (Metric) Reference 5, 10, 15, 20, 25°C
    Calibration pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option and temperature
    Calibration Points (pH) 1 to 5
    Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
    Calibration Points (Conductivity) Up to 5
    Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
    Resolution (Temperature) 0.1°C, 0.1°F
    Accuracy (Temperature) ±0.1°C
    Temperature Selection Manual or automatic with ATC temperature probe
    Temperature Probe Calibration 1 point temperature offset calibration
    Channels 2
    Display Type Graphic LCD with backlight
    Backlight Option Yes, selectable
    Keypad Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
    Measurement Modes pH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature
    Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
    Data Management Details Transfer single, range or all data points to printer or computer
    Data Points 2000 with date and time stamp
    Log Function Type Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous measure mode
    Memory Non-volatile memory preserves data log, calibration log and meter settings
    Alarm Output High/low limit alarm, calibration due alarm
    Methods 10 per channel with password protection
    Languages English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    Inputs BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)
    Outputs USB, RS232
    Power Supply Universal AC adapter (included) or 4 AA batteries (sold separately)
    AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
    Battery Type Four AA (sold separately)
    Battery Life 800 hours
    IP Rating IP-54
    Certifications/Compliance CE, TUV 3-1, FCC Class A
    Temperature (English) Operating 41° to 113°F (ambient)
    Temperature (Metric) Operating 5° to 45° C (ambient)
    Relative Humidity Range 5 to 85 %, non-condensing
    Dimensions (L x W x H) 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)
    Weight (Metric) 0.9kg
    Weight (English) 2 lb.
    Model Orion Star A215 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter
    Warranty 3 year meter warranty

    Record accurate and reliable pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature measurements with the Thermo Scientific™ Orion™ Star A215 pH and Conductivity Benchtop Meter, ideal for a wide range of applications and advanced pH and conductivity analysis in the lab. Use the two meter channels to measure pH and conductivity simultaneously or view each channel separately. Perform up to a 5 point calibration, log up to 2000 data point sets with time / date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer.

    The Thermo Scientific Orion Star A215 pH/ Conductivity Benchtop Meter is the ideal choice for any lab. Get the information you need quickly and easily from the large, backlit graphic LCD display. Informative display shows individual pH/mV/RmV or conductivity/TDS/salinity/ resistivity results with temperature, or all results at once. Additional helpful information includes electrode status, time, date, sample ID, user ID and calibration. For advanced users, features such as stability and averaging choices provide additional options.

    • Anyone can use this meter with its plain language screen prompts, soft keys that update for easy selection and a multilanguage interface that supports English, Spanish, French, Italian, German and Chinese
    • Don't miss a reading — AUTO-READ™ locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals
    • Up to five point pH calibration with automatic recognition for USA/NIST and DIN buffers and calibration editing to fix errors without a complete recalibration
    • Selectable cell constant allows for use with 2- or 4-cell conductivity cells
    • For accurate conductivity results, selectable reading reference temperatures of 5°, 10°, 15°, 20° or 25°C with linear, nonlinear, nLFu or EP curve options
    • Choice of practical salinity or natural sea water curves for salinity readings
    • Linear or ISO/EN 27888 curves for TDS
    • Nonvolatile memory holds up to 2000 data points with time and date stamp
    • Easily transfer data and keep meter software up-to-date with the USB and RS232 ports and complimentary data analysis software
    • Mix samples without a stir plate with direct control of the Orion Star stirrer probe (096019, sold separately)
    • Included electrode arm and newly designed probe holder make it easier to maintain and place probes into samples
    • Works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power
    • IP54-rated housing handles splashes and is wall-mountable if table space is a problem

  • Description & Specifications

Related Products

Product Content Feedback

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit