Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns Available on GSA/VA Contract for Federal Government customers only.

Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.

Manufacturer: Thermo Scientific™ 260853960

 View more versions of this product

Catalog No. 26-085-3960

  Check Availability
Add to Cart

    Specifications

    For Use With GC/MS
    Diameter 0.53mm
    USP Type G43
    Film Thickness 3μm
    Length (Metric) 30m
    Stationary Phase TraceGold TG-624
    Item Description 3um thickness; 0.53mm ID; 30m length

    Optimizing volatile organics analysis requires a gas chromatography (GC) column with high thermal stability. Low-bleed, midpolarity Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns offer the ideal performance and stability profile for this use.

    Engineered for Superior Performance

    • Low to midpolarity phase, similat to 6% cyanopropylphenyl methylpolysiloxane
    • High thermal stability—maximum temperatures up to 320°C
    • Highly inert—excellent peak shape for a wide range of compounds
    • Equivalent to USP G43
    Applications:
    • Residual solvents
    • Volatile organic compounds
    • Alcohols
    • Oxygenates
    A Leap Forward in Column Performance with Low Bleed and Superior Inertness
    • A low-bleed, stable column produces consistent results.
    • Low baseline noise enables improved limits of detection with enhanced resolution of low level analytes.
    • Minimizing column bleed extends column lifetime, leading to higher productivity.
    • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
    • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult-to-analyze compounds.
    Recommended For:
    • Alcohols
    • Ketones
    • Residual solvents
    • Volatiles
    Alternative Uses:
    • Oxygenates
    Similar to these Columns:
    • DB-624
    • VF-624ms
    • CP-Select 624 CB
    • ZB-624