Analytical scale silica-based packed columns for aqueous SEC (GFC) analysis. These are the best columns on the market for protein and enzyme separations and analyses. Pullulan exclusion limit: 700,000
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Polyvinyl alcohol based amino HILIC series (hydrophilic Interaction Chromatography). Durable with no shedding, these columns are excellent for light scattering and charged aerosol detectors.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
High performance type LW-400 series, superior efficiency versus LW-800 series, pore size specifically controlled for analyzing antibody type proteins, optimized for light scattering detection, high performance analysis of antibody drugs and various proteins, high lot-to-lot reproducibility, fulfills USP L20, L33, and L59 requirements, MW range (protein) = 10,000 to 700,000 Daltons, exclusion limit = 1,000,000 Daltons, dimensions 4.6 mm ID x 150 mm L
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Suitable for saccharides and polar sample analysis using HILIC mode, very high recovery rate of reducing saccharides vs other polymer/silica based columns, specially suited for LC/MS, dimensions: 2.0 mm ID x 150 mm L
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Pore size specifically controlled for analyzing proteins with molecular weights of several hundred thousand Daltons; optimized for light scattering detection, high performance analysis of antibody drugs and various proteins, high lot-to-lot reproducibility, fulfills USP L20, L33, and L59 requirements, MW range = 5,000 to 100,000 Daltons, exclusion limit = 170,000 Daltons, dimensions 8.0 mm ID x 300 mm L
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
The OHpak LB-806 is a high-performance, polymer-based packed column designed for aqueous Size Exclusion Chromatography (SEC) and Gel Filtration Chromatography (GFC). This robust column excels in applications utilizing light scattering detectors, thanks to its controlled low bleeding. It is compatible with versatile eluents, including N,N-Dimethylformamide (DMF) for polar polymers and meets USP-NF L38 and L39 requirements for regulated methods.
Aqueous SEC/GFC analysis for water-soluble macromolecules.
MALS compatibility with low column bleeding for sensitive detectors.
Can utilize DMF as an eluent for polar polymer analysis.
Fulfills USP-NF L38 and L39 requirements.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Polyhydroxymethacrylate columns for aqueous SEC (GFC) analysis. The eluent can be replaced with DMF for the analysis of polar polymers. Good replacement for protein analysis when silica cannot be used. Pullulan exclusion limit: 500,000,000
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More