MilliporeSigma™ Supelco™ Ascentis™ Express HILIC HPLC Column, 2.7 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | Silica |
| Phase | Reversed Phase |
| Matrix | Silica Phase/Fused-Core Particle Platform |
| Endcapped | No |
| pH | 2 to 8 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express OH5 HPLC Column, 5 μm Particle Size
Ascentis™ Express OH5 columns can be used for traditional normal phase separations using non-polar, totally organic mobile phases or for aqueous normal phase chromatography with the typical mobile phases for hydrophilic interactive liquid chromatography (HILIC) of basic, acidic, zwitterionic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Hydroxy, Penta- |
| Phase | Reversed Phase |
| Matrix | Hydroxy, Penta- Phase/Fused-Core Particle Platform |
| Endcapped | No |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C18 HPLC Column, 5 μm Particle Size
Ascentis™ Express 5 μm C18 is a high-speed, high-performance liquid chromatography column based on the highly efficient Fused-Core™ particle design.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express HILIC UHPLC Column, 2 μm Particle Size
Contains a bare silica stationary phase that can be used for traditional normal phase separations or aqueous normal phase chromatography.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2 μm |
| Stationary Phase | Silica |
| Phase | Reversed Phase |
| Matrix | Silica Phase/Fused-Core Particle Platform |
| Endcapped | No |
| Technique | Fused-Core UHPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C8 HPLC Column, 2.7 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | C8 (Octyl) |
| Phase | Reversed Phase |
| Matrix | C8 (Octyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C18 UHPLC Column, 2 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower back pressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2 μm |
| Stationary Phase | C18 (octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (octadecyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core UHPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C8 UHPLC Column, 2 μm Particle Size
Densely bonded, extensively endcapped dimethyloctyl stationary phase of Ascentis™ Express 2 μm C8 provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2 μm |
| Stationary Phase | C8 (Octyl) |
| Phase | Reversed Phase |
| Matrix | C8 (Octyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| Technique | Fused-Core UHPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express Biphenyl Column, 2.7 μm Particle Size
The Ascentis™ Express biphenyl phase chemistry offers alternative selectivity for pharmaceutical analytes and drug metabolites that are not well retained or difficult to resolve on traditional alkyl (C18) and phenyl bonded phases.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | Biphenyl |
| Phase | Reversed Phase |
| Matrix | Biphenyl Phase/Particle Platform (Fused-Core) |
| Endcapped | Yes |
| Material | Stainless Steel Hardware |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express Phenyl-Hexyl HPLC Column, 2.7 μm Particle Size
Ascentis™ Express Phenyl-Hexyl phase columns have unique selectivity arising from solute interaction with the aromatic ring and its delocalized electrons. It is complementary (orthogonal) to both C18 and RP-Amide phases because of this unique aromaticity.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | Phenyl-Hexyl |
| Phase | Reversed Phase |
| Matrix | Phenyl-Hexyl Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express ES-Cyano HPLC Column, 2.7 μm Particle Size
The sterically protected, extensively endcapped diisopropyl-cyanopropylsilane stationary phase of Ascentis™ Express ES-Cyano provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | Diisopropyl-Cyanopropylsilane |
| Phase | Reversed Phase |
| Matrix | Diisopropyl-Cyanopropylsilane Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express ES-Cyano HPLC Column, 5 μm Particle Size
The sterically protected, extensively endcapped diisopropyl-cyanopropylsilane stationary phase of Ascentis™ Express ES-Cyano provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Diisopropyl-Cyanopropylsilane |
| Phase | Reversed Phase |
| Matrix | Diisopropyl-Cyanopropylsilane Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express ES-Cyano UHPLC Column, 2 μm Particle Size
The sterically protected, extensively endcapped diisopropyl-cyanopropylsilane stationary phase of Ascentis™ Express 2 μm ES-Cyano provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2 μm |
| Stationary Phase | Diisopropyl-Cyanopropylsilane |
| Phase | Reversed Phase |
| Matrix | Diisopropyl-Cyanopropylsilane Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 1 to 8 |
| Technique | Fused-Core UHPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C8 Capillary HPLC Column, 2.7 μm Particle Size
Ascentis™ Express HPLC columns, through the use of Fused-Core™ particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles while maintaining lower backpressures.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 2.7 μm |
| Stationary Phase | C8 (Octyl) |
| Phase | Reversed Phase |
| Matrix | C8 (Octyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express HILIC HPLC Column, 5 μm Particle Size
The bare silica stationary phase of Ascentis™ Express 5 μm HILIC provides a column that can be used for traditional normal phase separations using non-polar, totally organic mobile phases or for aqueous normal phase chromatography with the typical reversed-phase mobile phases for hydrophilic interactive liquid chromatography (HILIC) of basic, acidic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | Silica |
| Phase | Reversed Phase |
| Matrix | Silica Phase/Fused-Core Particle Platform |
| Endcapped | No |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ Ascentis™ Express C8 HPLC Column, 5 μm Particle Size
The densely bonded, extensively endcapped dimethyloctyl stationary phase of Ascentis™ Express 5 μm C8 provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds.
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Stationary Phase | C8 (Octyl) |
| Phase | Reversed Phase |
| Matrix | C8 (Octyl) Phase/Fused-Core Particle Platform |
| Endcapped | Yes |
| pH | 2 to 9 |
| Technique | Fused-Core HPLC |
| Product Line | Ascentis |