Filtered Search Results
ANDWIN SCIENTIFIC ALUMINA HEARTH PLATE FP-113C
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
NC2739130 ALUMINA HEARTH PLATE FP-113C
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cole-Parmer Digi-Sense Type-J High-Temperature Fiberglass-Insulated Probe Mini-Connector, Exposed 10ft 20 -Gauge
Fiberglass wire is not recommended for use in moist or wet environments. Exposed-junction probes are not recommended for use with aqueous solutions. Do not subject type J exposed-junction probes to moisture as they will rust.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Beckman Coulter LAB EQUIP BOTTLE HDPE 300M
LAB EQUIP BOTTLE HDPE 300M
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Grainger THERMOSTAT ACCESSORY ELEMENT
502762673 THERMOSTAT ACCESSORY ELEMENT
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Omega Engineering, Inc. THERMOCOUPLE WIRE-T TYPE
Thermocouple Wire T TypeTT-T-24-SLE-1000
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Chemglass Life Sciences 1/4" Dia X 18" Long PTFE Coated Thermocouple Probe Type "J"
1/4" Dia X 18" Long PTFE Coated Thermocouple Probe Type "J". For use with Temperature Controllers CG-15001, CG-3200, CG-3202, CG-3404, CG-3206, CG-3209, and CG-3210. Thermocouples have a standard male plug (OST) and are all PFA COATED.Maximum Probe Temperature Based on Coating- FEP is 200°C and the Black PFA is 250°C
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
THERMO SCI 3P CAD NITON ANALYZERS SOIL GUARD KAPTON WINDOWS REPL
NC3871128 SOIL GUARD KAPTON WINDOWS REPL
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Grainger Heating Element 7.75 in Insert L
The Grainger Approved Replacement Element for Kenmore Dryers is a 240V 5400W heating element that fits multiple Kenmore dryer models including 110.67762700, 110.67763700, 110.67764700, 110.67766700, 110.67768700, 110.67769700, 110.67771700, 110.67772700, 110.67773700, 110.67774700, 110.67776700, 110.67778700, 110.67779700, 110.67781700, 110.67782700, 110.67783700, 110.67784700, 110.67786700, 110.67787700, 110.67788700, 110.67789700, 110.67791700, and 110.67792700. This heating element has coil-style terminals and measures approximately 9-1/4 Inch by 4-5/8 Inch. It is made of corrugated alloy sheath material.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences PRO-LINE Archival Sleeving A4 with Clear-Sealed Flap, 8.25 x 11¾"
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Our specially formulated 3-mil archival polypropylene has a physical density that is less than other sleeving materials, making it more pliable and gentle to your film. Strong and durable, PRO-LINE won't become brittle or abrade film. PRO-LINE sleeving is optically clear, neutral in color, and has a unique anti-Newton ring surface that reduces distracting Newton ring as well as minimizing the actual surface area that is in contact with your film.
Type: Clear-Sealed Flap
Size: 8.25 x 11¾"
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Kurt J Lesker Company THERMOCOUPLE GAUGE TUBES
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
OEM Part NUMBER: DV-6M; Flange: 1/8" NPT MALE stainless steel
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Omega Engineering, Inc. SUBMINI T/C ASSMBLY TMQSS02012
This item has a minimum order quantity of 6 per supplier requirements.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Chemglass Life Sciences PT100 Sensor, Constructed with Shielded Cable, the Lemo Connector Provides An Area for a Ground Connection, PFA Coated, 1/4" OD x 45" Long, Style "B", Fits Reactor Capacity: 50L (Tall)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
PT100 Sensor, Constructed with Shielded Cable, the Lemo Connector Provides An Area for a Ground Connection, PFA Coated, 1/4" OD x 45" Long, Style "B", Fits Reactor Capacity: 50L (Tall). PT100 RTD temperature sensor is for direct insertion into flasks and process reactors using any O-Ring style compression adapter, such as the CG-1042-E. Probes are constructed using shielded cable to ensure a clean signal. Style B has a Lemo Connector direct wired to a 12 foot lead and is for use with all Huber circulators permitting process temperature control based on the contents of the reactor. Sensor is constructed using GREEN shielded wire/cable. Lemo connector can be used as a ground for the probe using an optional grounding clip and wire. An adapter having a female Lemo connector to the 2-blade mini plug is available to allow use of the Style B sensors with equipment having this connection.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Omega Engineering, Inc. 80IN IEC STRPT LEADS THERMOCOU
NC3714982 80IN IEC STRPT LEADS THERMOCOU
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Chemglass Life Sciences J-KEM Needle tip probe 3.5" K
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
J-KEM Needle tip probe 3.5" K. Hypodermic needle thermocouples (17 gauge) are ideal for measuring and controlling the temperature of small volumes and inert reactions. Temperature measuring end of the thermocouple is at the tip, so only the first 2 mm of the probe needs liquid contact for accurate temperature measurement forms an air tight seal when inserted through a septum. Needles are sealed on the end for liquid tight applications. Comes with 72 inches of attached Teflon extension wire. Type K input: -50 to 1200°C
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences Thermowell heating mantle1EA
Economical and dependable. These mantles have a ceramic heat cavity (resistance wire completely embedded) a grounded metal housing for safer operation a low profile that permits magnetic stirring and can be operated at up to 550 C. May be used as an air or sand bath. All models have a 36 in. 3-wire integral power cord with U.S. plug (used as an interconnector plug with POWERMITE(TM) heat controllers). 50/60AHz.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More