Manual Gas Tight Syringes
Gas tight syringes for manual injections on GC instruments; includes fixed-needle, removable-needle formats in various sizes, needle gauges, needle point styles, and terminations; includes zero dead-volume and headspace syringes.
- (16)
- (10)
- (31)
- (7)
- (89)
- (26)
- (1)
- (60)
- (6)
- (1)
- (2)
- (9)
- (1)
- (1)
- (2)
- (23)
- (1)
- (2)
- (43)
- (1)
- (9)
- (58)
- (43)
- (23)
- (5)
- (58)
- (7)
- (45)
- (3)
- (13)
- (11)
- (1)
- (91)
- (10)
- (61)
- (23)
- (12)
- (14)
- (48)
- (10)
- (3)
- (3)
- (10)
- (23)
- (1)
- (1)
- (134)
- (11)
- (4)
- (5)
- (1)
- (3)
- (102)
- (110)
- (1)
- (44)
- (2)
- (2)
- (16)
- (7)
- (7)
- (39)
- (15)
- (41)
- (59)
- (1)
- (2)
- (1)
- (4)
- (4)
- (218)
- (1)
- (8)
- (1)
- (8)
- (7)
- (303)
- (13)
- (14)
- (6)
- (185)
- (1)
- (2)
- (14)
- (1)
- (1)
- (1)
- (4)
- (2)
- (24)
- (4)
- (9)
- (2)
- (12)
- (11)
- (5)
- (2)
- (6)
- (2)
- (25)
- (1)
- (3)
- (17)
- (2)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (7)
- (5)
Filtered Search Results
Restek™ Presents Hamilton Standard Microliter Syringes for Agilent 7673/7683/6850 GCs, 0.5 μL
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Agilent 7673, 7683, 7693A, and 6850 Autosamplers.
| For Use With (Equipment) | Agilent 7673, 7683, 7693A and 6850 Autosamplers |
|---|---|
| Product Type | Hamilton Standard Microliter Syringes for Agilent Autosamplers |
| Connection Type | Autosampler Removable |
| Volume (Metric) | 0.5 μL |
| Model | 7000.5 |
| Quantity | Ea. |
| Length (English) Needle | 1.71 in. |
| Length (Metric) Needle | 43.4 mm |
Restek™ Replacement Valve for SGE Gas-Tight Syringes Fitted with Removable Needle Valve
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For gas-tight syringes with shut-off valves.
Hamilton™ 1800 Series Gastight™ Fixed-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
| Needle Point Number | 2 |
|---|---|
| Quantity | 1/Pk. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
| Max. Pressure | 1000 psig (68.9 bar) |
| Product Type | Gastight, Cemented Needle |
| Connection Type | Cemented |
| Max. Temperature (English) | 122°F |
| Needle Point Style | 2 |
| Length (English) Needle | 2 in. |
| Autoclavable | Not Autoclavable |
| Min. Temperature (Metric) | 10°C |
Hamilton™ 700/700 Microliter™: RN Termination
Syringes have a built-in syringe guide, designed to prevent the plunger from bending and pulling out of the syringe
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: DX Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
| Includes | Instrument plunger stop |
|---|---|
| Needle Point Number | No Needle Included |
| For Use With (Equipment) | Microlab 500 Diluters/Dispensers |
| Product Type | Gastight Syringe |
| Connection Type | Luer Lock |
| Max. Temperature (English) | 239°F |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip) |
| Max. Temperature (Metric) | 115°C |
| Autoclavable | Autoclavable |
Hamilton™ 700/1700 Series Microliter™/Gastight™ On-Column Manual Injection Syringes
Syringes are designed to work with On-Column GC Injectors.
| Diameter (English) Inner | 0.019 in. |
|---|---|
| For Use With (Equipment) | On-Column GC Injectors |
| Product Type | Microliter Syringe |
| Diameter (Metric) Outer | 0.66 cm |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.26 in. |
| Volume (Metric) | 10 μL |
| Model | 701 |
| Diameter (Metric) Inner | 0.048 cm |
| Material | Stainless Steel, Borosilicate Glass, Fused Silica |
| Max. Temperature (Metric) | 115°C |
| Sterility | Sterile |
| Max. Pressure | 2000 psi |
Hamilton™ 1700 Series Gastight™ Gel Loading Syringes, 10uL
Syringes are designed to work for multiplex DNA sequencing applications
| Needle Point Number | 3 |
|---|---|
| Max. Temperature (English) | 122°F |
| Volume (Metric) | 10 μL |
| Min. Temperature (English) | 50°F |
| Max. Temperature (Metric) | 50°C |
| For Use With (Application) | Designed to work for multiplex DNA sequencing applications |
| Autoclavable | Not Autoclavable |
| Sterility | Sterile |
| Max. Pressure | 1000 psi |
Hamilton™ 700 and 1700 Series Gastight™ and Microliter™ Digital Syringes: N Termination
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
| Accuracy | ±0.5% |
|---|---|
| Length (Metric) | 51 mm |
| Length (English) | 2 in. |
| Quantity | Ea. |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
Hamilton™ 7000 Series Gastight™ and Microliter™ Digital Syringes: KH Termination
Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL
| Length (Metric) | 70 mm |
|---|---|
| Length (English) | 2.75 in. |
| Quantity | Ea. |
| Min. Temperature (English) | 50°F |
| Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
| Max. Temperature (Metric) | 115°C |
| For Use With (Application) | Analytical instrument calibration (AA/ICP, GC, HPLC) , prepare standards and spike samples, eliminates parallax errors by providing a digital readout on its integrated LCD screen and also used for pipetting and HPLC injections |
| Max. Pressure | 6000 psi |
| Diameter (Metric) Outer | 7.82 mm |
| Connection Type | Knurled Hub |
| Max. Temperature (English) | 239°F |
| Diameter (English) Outer | 0.3 in. |
| Length (English) Needle | 2.75 in. |
| Autoclavable | Autoclavable |
| Min. Temperature (Metric) | 10°C |
| Diameter (English) Outer Needle | 0.02 in. |
Hamilton™ Constant Rate-700 HPLC Syringes & Replacement Parts
Syringes are designed to delive reasy, reproducible injection of liquid samples into an injector on HPLC instrumentation. The CR-700 standardizes three major variables: sample volume, rate of injection, and depth of needle penetration. Even when operated by different technicians, the CR-700 provides reproducibility of +1% of the total syringe volume in routine procedures.
| For Use With (Equipment) | HPLC Injection Valves |
|---|---|
| Needle Point Style | Blunt |
| Length (English) Needle | 2 in. |
Restek™ 1700 Series Manual Gas Tight Syringes (Hamilton)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Restek™ Presents Hamilton PTFE Fluorocarbon Resin-Tip, Gas-Tight Syringes: Needle: N
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Suitable for gases or liquids, for maximum inertness.
| Needle Point Number | 2 |
|---|---|
| Product Type | Hamilton PTFE Tip, Gas-Tight Syringes |
| Connection Type | Cemented |
| Needle Point Style | 2 |
| Quantity | Ea. |
| Material | PTFE (Tip) |
| Length (English) Needle | 2 in. |
| For Use With (Application) | Suitable for gases or liquids for maximum inertness |
Restek™ Presents SGE Micro-Volume, Positive Displacement Syringes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
High precision and accuracy down to 0.1μL.
| Product Type | SGE Micro-Volume, Positive Displacement Syringes |
|---|---|
| Quantity | Ea. |
| Material | PTFE (Tip) |
| For Use With (Application) | For high pressure injection |
Restek™ Presents Hamilton Economical Microliter Liquid-Type Syringes for Rheodyne and Valco Valve
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Rheodyne and Valco valves.
| Needle Point Number | 3 |
|---|---|
| Diameter (Metric) Inner Needle | 0.15 mm |
| For Use With (Equipment) | Rheodyne and Valco Valves |
| Product Type | Hamilton Economical Microliter Liquid-Type Syringe |
| Connection Type | Cemented |
| Needle Point Style | 3 |
| Quantity | Ea. |
| Diameter (Metric) Outer Needle | 0.72 mm |
| Length (English) Needle | 2 in. |
| Needle Gauge | 22s G |
| Diameter (English) Outer Needle | 0.028 in. |
| Diameter (English) Inner Needle | 0.006 in. |