Multigas Portable Detectors
Filtered Search Results
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
| Detection Limits | 0.5 ppm of methane |
| Width (Metric) | 22.9 cm |
| Detector Type | Flame Ionization Detector (FID) |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | 0 to 30,000 ppm (methane) |
| Battery Type | Lithium-ion |
| Repeatability | ±2% at 500 ppm of methane |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
| Width (English) | 9 in. |
|---|---|
| Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
| Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
| Width (Metric) | 22.9 cm |
| Detector Type | Dual Configured with FID and PID |
| Flow Rate | 1 L/min., nominal at sample probe inlet |
| Components Measured | Most Organic and Inorganic Compounds |
| Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
| Battery Life | 10 hours at 0°C |
| Voltage | 120 V |
| Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
| Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
| Height (English) | 11.5 in. |
| Height (Metric) | 29.2 cm |
| Warranty | One year from date of shipment |
| Depth (English) | 4 in. |
| Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
| Battery Type | Lithium-ion |
| Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
| Serial Interface | USB |
| Computer Requirements | USB port, Windows XP operating system or higher |
| Depth (Metric) | 10.2 cm |
| Fuel | 99.99% H2 for FID |
| Temperature Range (English) | 14°F to 113°F |
| Frequency | 50/60 Hz |
| Portable Operation Time | Minimum 10 hours |
| Temperature Range (Metric) | -10°C to 45°C |
| Depth (English) | 1 in. |
|---|---|
| Width (English) | 2.125 in. |
| Length (Metric) | 89 mm |
| Color | Charcoal Gray |
| Length (English) | 3.5 in. |
| Humidity Range | 10 to 95% RH (non-condensing) |
| For Use With (Application) | Ideal for use in Confined Space, Toxic Detection applications |
| Width (Metric) | 54 mm |
| Battery Type | Lithium |
| Alarm Types | Visual, Audible and vibrating |
| Battery Life | 18 Months |
| Display Type | Backlit LCD |
| IP Rating | IP67 |
| For Use With (Equipment) | MSA GALAXY GX2 Automated Test System and MSA Link Pro software |
| Depth (Metric) | 25 mm |
| Weight (English) | 4 oz. |
| Certifications/Compliance | cCSAus Class I Div 1 Groups A, B, C, D; Class II Div 1 Groups E, F, G Class III; Tamb: -40C to +60C T4; USA: UL 913 7th Edition; Canada: CSA 22.2 No. 157 |
| Temperature Range (Metric) | -10° to +40°C |
| Weight (Metric) | 113g |
MSC BW Technologies by Honeywell GasAlertQuattro, Multi-Gas, 1 ea
The GasAlertQuattro gas detector is a personal safety device designed to warn of hazardous gas at levels above user-defined alarm setpoints. It monitors 1, 2, 3, or 4 gases, including hydrogen sulfide (H2S), carbon monoxide (CO), combustible gases (LEL), and oxygen (O2).
- Monitors 1, 2, 3, or 4 gases (H2S, CO, LEL, O2)
- Warns of hazardous gas levels with visual, audio, and vibrate alarms
- Liquid crystal display (LCD) shows readings, alarm setpoints, and messages
- Single button operation for activation/deactivation and data viewing
- Configurable via Fleet Manager II software
- Performs battery test, segment test, and sensor self-test during startup
- Supports rechargeable battery pack or 3 alkaline batteries
- Designed for use in potentially explosive atmospheres
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC BW Technologies by Honeywell GasAlertQuattro Alkaline 4-Gas Detector, 1 ea
The GasAlertQuattro is a rugged and reliable four-gas detector designed for industrial applications like confined space entry. It features simple one-button operation and flexible power options, with a graphic LCD displaying operational information. IntelliFlash provides continuous visual confirmation of compliance, and it is fully compatible with the MicroDock II automatic test and calibration system.
- Rugged and reliable design
- Four-gas detection (%LEL, O2, H2S, CO)
- Simple one-button operation
- Flexible power options
- Graphic LCD with easy-to-identify icons
- Displays operational information, bump test, and calibration status
- IntelliFlash for continuous visual confirmation of operation and compliance
- Suitable for confined space entry
- Compatible with MicroDock II automatic test and calibration system
- Water resistant
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC BW Technologies GasAlertQuattro Detector, LEL, O2, H2S, CO, 1 ea
The GasAlertQuattro 4-Gas Detector is a durable unit for harsh environments, detecting %LEL, O2, H2S, and CO. It features an LCD, one-button operation, and IntelliFlash for continuous confirmation.
- Triple alarm system: ultra-bright bars, >95 dB audible, and vibrating
- Self-tests sensor integrity, circuitry, battery, and alarm functioning
- Interchangeable battery pack; can use 3 AA alkaline batteries
- Honeywell\'s SureCell Sensor technology detects toxins, resists interference
- Compatible with BW\'s MicroDock II for automatic test and calibration
- Datalogging and record-keeping capabilities
- Full two-year warranty including all sensors
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC Honeywell BW Multi-Gas Detector, 4-Gas, Alkaline Version, 1 ea
The Honeywell BW GasAlertQuattro multi-gas detector is a rugged, reliable device for personal gas detection. It features IntelliFlash™ for continuous visual compliance verification and detects up to four gases, suitable for industrial applications including confined space entry.
- IntelliFlash verifies operation and compliance
- Detects hydrogen sulfide, carbon monoxide, oxygen, and combustible gases
- Compact, lightweight design with built-in concussion-proof boot
- Compatible with MicroDock II automatic test and calibration system
- Full function self-test on start-up
- One-button operation and straightforward user interface
- Comprehensive data and event logging
- Field-proven SureCell sensors
- Multi-language support
- IP66/IP67 rated
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC BW Technologies Gas Alert Quattro, Portable, Alkaline Battery, 1 ea
The BW Technologies Yellow Gas AlertQuattro is a portable multi-gas detector designed for monitoring combustible gas, oxygen, hydrogen sulfide, and carbon monoxide. It features simple one-button operation and is compatible with the BW MicroDock II system.
- Compatible with MicroDock II automatic test and calibration system
- Detects combustible gas, oxygen, hydrogen sulfide, and carbon monoxide
- Simple one-button operation with audible, visual, and vibrating alarms
- Flexible power options and IntelliFlash for compliance confirmation
- Field-proven SureCell sensor performs in harsh environments
- Extensive data and event logging capability
- Full function self-test and continuous heartbeat pulses
- Flip display accessible via IR interface for tamper-proof operation
- Multi-language LCD displays all four gas concentrations
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
MSC BW Technologies Multi-Gas Detector, LEL/O2/H2S/CO, Alkaline Powered, 1 ea
The GasAlertQuattro multi-gas detector is a rugged and reliable instrument designed for simultaneous detection of combustible gases (%LEL), oxygen (O2), hydrogen sulfide (H2S), and carbon monoxide (CO). This model is powered by an alkaline pack utilizing 3 AA batteries, offering extended battery runtimes and simple one-button operation.
- Minimizes costs and training with one-button operation
- Field-proven SureCell sensors offer unprecedented performance
- Graphic LCD displays operational information with easy-to-identify icons
- IntelliFlash provides continuous visual confirmation of detector operation and compliance
- Compatible with MicroDock II automatic test and calibration system
- Comprehensive datalogging and event logging capacity
- Full function self-test of sensor(s), battery, circuit integrity, and alarms
- Built-in concussion-proof boot
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More