pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.
| Salinity Measurement Modes | Natural Seawater (ppt) or Practical Salinity (PSU) |
|---|---|
| Memory | Non-volatile |
| Cell Constant | 0.100 to 10.00 cm-1 |
| Measurement Modes | Conductivity with Temperature,Salinity with Temperature,TDS with Temperature |
| Temperature (Metric) Reference | 15.0, 20.0, 25.0 or 30.0°C |
| Temperature Coefficient | 0 to 10 %/°C |
| TDS Factor Range | 0.40 to 1.00 |
| Range (Salinity) | 0.00 to 80.0 ppt; 0.00 to 42.0 PSU |
| Data Management Details | Continuous, Auto-Read and Timed read modes |
| Temperature Compensation | Linear (0 to 10 %/°C) or off |
| Display Type | 5 in. backlit LCD |
| Accuracy (Salinity) | ±0.5 % of the reading ± 1 LSD |
| Resolution (Salinity) | 0.01, 0.1 ppt; 0.01, 0.1 PSU |
| Accuracy (Conductivity) | ±0.5 % of the reading ± 1 LSD |
| Data Points | 500 Sets with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | 8-pin MiniDIN for conductivity with built-in ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 700 grams |
| Calibration Points (Conductivity) | 1-5 points conductivity |
| Warranty | 3 year meter warranty |
| Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
| Range (Conductivity) | 0.00 μS to 500.0 mS |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
| Calibration | Conductivity, salinity, TDS and temperature |
| Calibration Points | 1 point salinity, 1-5 points TDS, 1 point temperature |
| Alarm Output | Calibration reminder alarm |
| Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
| Accuracy (TDS) | ±0.5 % of the reading ± 1 LSD |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Outputs | Computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | 23.0°F to 221.0°F |
| Weight (English) | 1.54 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Compatible Probes | 2-cell and 4-cell conductivity electrodes |
Thermo Scientific™ Orion Star™ A322 Conductivity Portable Meter
Accurately monitor conductivity, TDS, salinity, resistivity and temperature with this conductivity portable meter designed for challenging field tests.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Battery Life | 800 hr. |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 5000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity with calibration editing option and temperature |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A322 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
METTLER TOLEDO Burette Housing for EVA V1/V3 KF Titrator
Elevate your analysis with our specialized accessories for the EVA Karl Fischer V1 and V3 Titrators.
METTLER TOLEDO Large Titration Vessel with Thermostat Jacket for EVA V1/V3 KF Titrator
Elevate your analysis with our specialized accessories for the EVA Karl Fischer V1 and V3 Titrators.
Mettler Toledo Adapter Plate KFV GL80
Allow a titration vessel (or cell) to be mounted / fit properly in the titrator base, used with GL80-series titration vessels / cells
Mettler Toledo Adapter M24 NS14
Offers NS14/15 adapters (also known as adapter sleeves) for sensors/electrodes with certain shaft diameters
Mettler Toledo Titration Arm GL80
A modular accessory designed for (KF) titrators especially for the EVA series, it is part of a broader accessory kit often included in a cell kit
METTLER TOLEDO Adapter for Kinematica Homogenizer for EVA V1/V3 KF Titrator
Elevate your analysis with our specialized accessories for the EVA Karl Fischer V1 and V3 Titrators.
METTLER TOLEDO dPump Solvent Pump for EVA V1/V3 KF Titrator
Elevate your analysis with our specialized accessories for the EVA Karl Fischer V1 and V3 Titrators.
Thermo Scientific™ Orion™ Dissolved Oxygen/BOD Probe
Make any pH meter a dissolved oxygen meter with this dissolved oxygen/BOD probe.
| Dissolved Oxygen (Concentration Range) | 0 to 14 ppm |
|---|---|
| For Use With (Equipment) | Dissolved Oxygen/BOD Probe |
| Sensor Types | Polarographic Dissolved Oxygen Sensor |
| Temperature (Metric) Operating | 15°C to 35°C |
Mettler Toledo™ Galvanic Sensor
Robust and easy to use sensors. Mettler Toledo Indicating Galvanic Sensors have integrated temperature sensor. Galvanic dissolved oxygen sensor provides an easy way to measure DO.
| Connections | BNC/Cinch |
|---|---|
| Type | Dissolved Oxygen Sensor |
| For Use With (Equipment) | FG4 |
| Sensor Types | Dissolved Oxygen |
| Temperature (Metric) Operating | 0°C to 60°C |
| For Use With (Application) | DO |
Mettler Toledo™ Conductivity Meter SevenDirect SD30
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
The SevenDirect SD30 is an accurate and flexible benchtop meter for the determination of conductivity, total dissolved solids and salinity. The instrument is the replacement of the SevenCompact and is delivered with an EasyPlace sensor arm.
| Range (Resistivity) | 0 to 100 Mohm-cm |
|---|---|
| Resolution (Conductivity) | 0.001 to 1 |
| Memory | 2000 Standard Measurements |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Range (TDS) | 0 g/L to 100 g/L |
| Measurement Modes | Conductivity |
| Channels | 1 |
| Range (Salinity) | 0 to 80 ppt |
| Dimensions (L x W x H) | 195 x 205 x 65 mm |
| Data Management Details | PC, Printer, USB Stick |
| Display Type | Color TFT |
| IP Rating | IP54 |
| Accuracy (Conductivity) | 0.005 |
| Data Points | 2000 |
| Temperature Range (English) | -22°F to +266°F |
| Weight (English) | 1.9 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -30°C to +130°C |
| Accuracy (Temperature) | ±0.1°C between 0°C and 100°C |
| Weight (Metric) | 850 g |
Mettler Toledo™ Conductivity Meter NineFocus™ NF3000™
High-performance, multiparameter benchtop meter for compelling precision in pH, conductivity, ion concentration, redox, and dissolved oxygen determinations. The modular meter is at its best with the smart digital InLab™ DES™ sensors.
| Height (Metric) | 34 cm |
|---|---|
| Resolution (Conductivity) | 0.001 to 0.1 |
| Memory | 3000 Result Sets |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Log Function Type | Automatic by Interval or Event, Manual |
| Languages | Chinese Simplified, Chinese Traditional, English, French, German, Italian, Polish, Portuguese, Russian, Spanish, Thai, Turkish |
| Measurement Modes | Conductivity with Temperature |
| Calibration | Conductivity, TDS, Salinity, Temperature |
| Width (Metric) | 30 cm |
| Channels | 4 (Customizable with modules) |
| Accuracy | -30 to 130°C |
| Type | Conductivity Meter |
| Dimensions (L x W x H) | 40 x 30 x 34 cm |
| Data Management Details | PC, Printer, USB stick |
| Display Type | Color TFT (7 in.) |
| IP Rating | IP52 |
| Accuracy (Conductivity) | 0.5 % |
| Data Points | 2000 |
| Backlight Option | Yes |
| Certifications/Compliance | CE, WEEE, RoHS |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -30°C to +130°C |
| Accuracy (Temperature) | ±0.1°C between 0°C and 100°C |
| Weight (Metric) | 2 kg |
Thermo Scientific™ Orion Star™ A122 Conductivity Portable Meter
Take simple conductivity, TDS and temperature measurements with this conductivity portable meter with easy operation for basic field testing.
| Memory | Non-volatile memory preserves log and settings |
|---|---|
| Languages | English |
| Cell Constant | 0.001 to 10cm-1 |
| Measurement Modes | Conductivity,TDS with Temperature |
| Temperature (Metric) Reference | 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Battery Life | 2000 hr. |
| Data Management Details | Internal data point memory |
| Temperature Compensation | Linear |
| Display Type | LCD |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit |
| Data Points | 50 |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 1 |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Conductivity) | 0.01 μS minimum, auto ranging up to 3 significant digits |
| Range (Conductivity) | 0.01 μS/cm to 200.0 mS/cm |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Range (TDS) | 1 to 19,999 mg/L |
| Resolution (TDS) | 1 mg/L |
| Calibration | Conductivity and temperature |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| IP Rating | IP67 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Simple with highlighted measure key, scroll and shortcut keys |
| Model | Orion Star A122 Conductivity/TDS/Temperature Portable Meter |
| Outputs | None |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
OHAUS™ Aquasearcher™ Conductivity Meter AB33EC
The Aquasearcher™ Conductivity Meter AB33EC is a highly reliable benchtop meter designed to measure conductivity, total dissolved solids (TDS), salinity, and resistivity with temperature measurements.
| Display Type | LCD One-line Dot Matrix |
|---|---|
| IP Rating | None |
| Range (Resistivity) | 1 to 100 MΩ-cm |
| Range (Conductivity) | 0.001 μS/cm minimum, auto-range |
| Accuracy (Conductivity) | ±0.5% Reading ±2 Least Significant Digit |
| Outputs | RS232, USB Device (Included) |
| Data Points | 1000 |
| Range (TDS) | 0.1 mg/L to 200 g/L |
| Measurement Modes | Auto-stop,Continuous |
| Temperature Range (Metric) | -5°C to +110°C |
| Range (Salinity) | 0.01 psu minimum, auto-range |