Slide Mounting Media
- (30)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (2)
- (1)
- (23)
- (2)
- (1)
- (1)
- (3)
- (6)
- (1)
- (3)
- (1)
- (2)
- (8)
- (6)
- (1)
- (2)
- (1)
- (17)
- (7)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (3)
- (3)
- (2)
- (12)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (21)
- (12)
- (1)
- (2)
- (23)
- (10)
- (2)
Filtered Search Results
National Diagnostics HYDROMOUNT 100 ML
Hydromount, Nonfluorescing aqueous mounting medium, 100 ML
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Rarecyte ArgoFluor Mounting Media, 10mL
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Solution for adhering a coverslip to a microscope slide. To be used with RareCyte’s AccuCyte/RarePlex liquid biopsy products and assays. DO NOT USE with RareCyte’s Orion/ArgoFluor products.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biotium DROPNSTAIN EVERBRITE DAPI 2ML
DROPNSTAIN EVERBRITE DAPI 2ML
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Technovit Embedding Mold HistoForm Q
An important prerequisite for easy-to-cut specimens is a mold with a special profile which will provide specimen blocks for easy application and simple cutting. This is achieved with Histoform S, an embedding mold composed of new material with a special shape.
All essential requirements such as material-saving volume, easy-to-cut shape, unlimited shelf life, easy removal of the embedded specimens because of the conical shape and the PTFE material, excellent temperature dissipation by way of refined steel bottom, and accurate and easy fixing of the specimen blocks byspecial grooves were achieved with Histoform S, in cooperation with renowned users.
Curing temperature measurements have confirmed that at this volume the combination of Teflon and refined steel will result in a considerably lower polymerization temperature. Cavities are 20mm wide x16mm high x10mm deep.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF200, Glycerol Based, Hardening 10 ML
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Glycerol solution containing an amine-based antifadent.
Material: Glycerol Based
Type: Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Permount™ Mounting Medium 500 ML
Permount is a toluene-based synthetic resin mounting medium that is ideal for rapid mounting and long term storage of slides. Its low viscosity allows for a thinner mounting layer offering better optical quality and bubble-free preparations. It has a refractive index near that of a fixed protein which helps to keep images free of distortion. Use for mounting coverslips to slides with thick or thin specimens. Permount preserves most biological stains with little or no fading when the slides are stored in darkness. It contains an anti-oxidant to prevent the formation of annular rings and its high softening point (155 degree C/311 degree F) makes it suitable for microprojection.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC CAROUSEL MOUNT ASMBLS- AS HI
CAROUSEL MOUNT ASMBLS- AS HI
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Embed 812 Resin 450 ML
EMbed 812 has the same characteristics as Epon 812, physically, and provides the same results in preservation, handling, curing and sectioning. EMbed 812 may cause etching on selected plastics. All formulas for mixing and using Epon 812 can be applied to EMbed 812, e.g. Luft's procedure, Mollenhauer's and EPON-ARALDITE mixtures.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Kessil A Dicon Brand PR160L Mounting Module, for PR300 Shielding Box Plus
Kessil PR160L Mounting Module is a mechanical interface designed to securely mount Kessil PR160L-275 and PR160L-300 LED Lights into the PR300 Shielding Box Plus for a fully protected environment with efficent temperature control. This module ensures perfect lamp alignment to maintain consistent geometry and uniform irradiation during high-intensity photoreactions.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Mark V Laboratory Inc Green Phenolic Mounting Powder, 5 LBS.
This item has a minimum order quantity of 3 per supplier requirements Colored Phenolic Thermoset Powders are used in Mounting Press\"s for specimen mounting. Mounts are made at 150 degrees C at pressures between 3000-4200 psi. The different colors offer contrast to the parts being mounted when examined under a microscope.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences LR White resin only; Med. Grade Catalyzed
A very low viscosity (8cps), non-toxic resin, suitable for both Light and Electron Microscopy. LR White is a polar monomer polyhydroxylated acromatic acrylic resin. It can be cured by heat or by UV light. Sections of polymerized LR White resin are hydrophilic. This character allows immuno-cytochemistry reagents to easily penetrate into the sections and etching of the sections is not necessary (etching sections will effect delicate tissue antigens). LR White sections also show minimal non-specific staining. Its low viscosity makes it ideal for infiltrating decalcified bone and teeth as well as plant tissues. It is available in medium and hard grade.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Glycerol Mounting Medium w/ DAPI & DABCO 100 ML
EMS Glycerol with DAPI and DABCO is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. It prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine, Redox. Fluorescence is retained during prolonged storage at 4 deg C in the dark.
This mounting medium is fortified with DAPI which is a counter-stain for DNA. This product is to be used in situ hybridization techniques or other methods where fluorescence of DNA staining is required. DAPI excites at 360nm and emits at 460nm, producing a blue fluorescence. RNA is also stained with DAPI.
Not recommended for phycoethyrin (PE), phycocyanin (PC) and allophycocyanin (APC).
Reagent: Ready to use mounting medium with anti-fading agent
Refractive Index: 1.4617
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution CFM-1 Plus, Glycerol Based, Non Hardening 10 ML
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Glycerol-PBS buffered solution with a refractive index of ~1.52. With anime antifadent.
Material: Glycerol Based
Type: Non Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences JB-4™ Solution B 30 ML
A water soluble embedding media which is based on Glycol Methacrylate (GMA) plastic embedding. It is intended for use in preparing samples for high resolution microscopes (HRLM). The catalyzed monomer acts as a dehydration and infiltration agent; therefore, complete dehydration through 100% ethanol is not necessary (although recommended for large or dense tissues). Conventional paraffin sections have a greater degree of shrinkage and produce inadequate morphology when compared to JB-4.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Rowley Biochemical Institute Inc ACETIC ACID 0.2 AQUEOUS 1 QT
NC3432185 ACETIC ACID 0.2 AQUEOUS 1 QT
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More