Choose the brand aligned with your industry so we can best serve your needs.
For researchers, scientists, and technical professionals: Your one-stop shop for the complete range of laboratory, production, and safety products and services.
Connectors, tubing, and other general accessories for HPLC; includes unions, tees, and crosses, fingertight fittings, column connectors, capillary tubing in a variety of materials, cutters, retention gap kits, sleeves, and seals.
The RapiFluor-MS Dextran Calibration Ladder was developed to fully utilize the BEH glycan column for glycan profiling. It enables calibration of glycan profiles from UPLC-HILIC/FLR systems, assigning glucose unit (GU) values. This calibration ladder provides good peak shape and reliable identification from 2 to 30 Glucose Units, extending the range of other dextran ladder standards and improving large glycan retention time assignment.
Calibration range of 2 to 30 glucose units (GU).
Packaged as 50 μg of lyophilized solid.
Synthesized via ethanolamine reductive amination and rapid labeling with RapiFluor-MS.
Long-term storage at -20 °C prior to solubilization.
Solubilized product can be aliquoted and frozen at -80 °C for up to 3 months, or stored at -4 °C to -10 °C for up to one week.
Avoid freeze/thaw cycles post-solubilization.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This tubing assembly is an HPLC Post Column Tubing designed for fluidic connections in chromatography systems. It features a 0.005 in. inner diameter and a length of 35 in., making it suitable for connecting the column to the detector. Made from PEEK material, it is essential for ACQUITY 30cm Column Heater/Cooler setups and AQT testing.
Made from PEEK material.
Features a 0.005 in. inner diameter.
Measures 35 in. in length.
Designed for HPLC post-column applications.
Connects the column outlet to the detector.
Required for AQT testing.
Compatible with ACQUITY 30cm Column Heater/Cooler.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This product is a spare parts kit containing 7 open and 7 closed solvent bottle caps. Designed for HPLC systems, these multi-coloured caps aid in solvent bottle identification.
Contains 7 open and 7 closed solvent bottle caps.
Caps are multi-coloured for easy identification.
Designed for HPLC systems.
Available as a spare parts kit.
Replaced as required for system maintenance.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This rebuild kit provides the necessary components to rebuild an Accumulator Pumphead. It is designed for performance maintenance of UPLC systems, compatible with UPLC H-Class System, nanoUPLC System, and 2D System. Replacement is scheduled as required.
Includes plunger, seals, and check valve
System type: UPLC
Compatible with UPLC H-Class System, nanoUPLC System, 2D System
The GlycoWorks RapiFluor-MS Labeling Module is a 96-sample kit for N-glycan analysis. It uses RapiFluor-MS to enhance fluorescence quantification and mass spectral response, streamlining sample preparation for analysis in as little as 30 minutes.
Enhanced fluorescence quantification and mass spectral response
Single label for comprehensive N-glycan analysis and monitoring
Streamlined preparation for rapid deglycosylation, labeling, and clean-up in <30 minutes
Dual detection capabilities for versatile analysis
Optimized reagents ensure efficient N-glycan release and high yield
Robust clean-up via HILIC μElution Plate
High throughput, designed for 96 samples
Mass spectrometry compatibility for direct LC-MS analysis
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
This kit provides a replacement set of stainless steel tubing assemblies for the 515 Isocratic Pump, including all the external tubing assemblies that would need to be replaced.
Replacement set of stainless steel tubing assemblies
Designed for 515 Isocratic Pump
Contains all external tubing assemblies
Suitable for HPLC systems
Can be replaced as required
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More
Small and Specialty Supplier Partner Small and/or specialty supplier based on Federal laws and SBA requirements. Learn More
EZ-Waste Solvent Waste System is designed to be an affordable solution for liquid waste disposal.Carbon exhaust filter traps solvent vapors,tube fittings secure waste tubes to carboy, providing the closes system necessary to prevent spills. 90° adapter included for maximum storage flexibility. VersaCap™ Technology eliminiates need to remove tubing from open cap to install closed cap. Plugs included for unused ports. Closed 83B VersaCap™ included for safe transport. Replaceable sulfer cured EPDM gasket for high chemical compatibility against aggressive organic solvents.
Encompass Procurement Services Non-distribution item offered as a customer accommodation; additional freight charges may apply. Learn More