HPLC Guard Columns and Cartridges
- (30)
- (1)
- (30)
- (14)
- (1)
- (4)
- (167)
- (1)
- (1)
- (6)
- (120)
- (3)
- (1)
- (53)
- (3)
- (3)
- (1)
- (11)
- (17)
- (23)
- (13)
- (2)
- (22)
- (3)
- (80)
- (1)
- (13)
- (3)
- (2)
- (30)
- (3)
- (22)
- (9)
- (2)
- (24)
- (3)
- (1)
- (2)
- (55)
- (2)
- (70)
- (5)
- (5)
- (5)
- (6)
- (333)
- (3)
- (2)
- (7)
- (1)
- (7)
- (3)
- (3)
- (3)
- (15)
- (4)
- (1)
- (22)
- (2)
- (149)
- (5)
- (1)
- (4)
- (2)
- (73)
- (1)
- (14)
- (130)
- (4)
- (95)
- (11)
- (1)
- (8)
- (2)
- (2)
- (2)
- (74)
- (18)
- (4)
- (3)
- (2)
- (23)
- (12)
- (10)
- (2)
- (4)
- (1)
- (36)
- (9)
- (2)
- (5)
- (3)
- (3)
- (1)
- (1)
- (1)
- (3)
- (6)
- (1)
- (42)
- (2)
- (3)
- (45)
- (3)
- (5)
Filtered Search Results
Microsolv Technology Corporation Guard Column Cartridges, RP C18 Wide Pore, 5um, 300A. 2.1mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 5µm, Cogent RP C18™ Wide Pore Stationary Phase. They are double end capped ( fully ), with traditional bonding of an 18 carbon silane to the highest purity silica available. Designed to protect your 2.1mm ID, RP C18, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Microsolv Technology Corporation Guard Column Cartridges, RP C18 ABX, 3um, 100A. 4.0mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 3µm, Cogent RP C18 ABX™ Stationary Phase. They are specially end capped ( bulky ), with traditional bonding of an 18 carbon ligand to the highest purity silica available.Designed to protect your 3.0, 4.0 or 4.6mm ID, RP C18 ABX, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Microsolv Technology Corporation Guard Column Cartridges, RP C18 ABX, 3um, 100A. 2.1mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 3µm, Cogent RP C18 ABX™ Stationary Phase. They are specially end capped ( bulky ), with traditional bonding of an 18 carbon ligand to the highest purity silica available.Designed to protect your 2.1mm ID, RP C18 ABX, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Microsolv Technology Corporation Guard Column Cartridges, RP C18, 5um, 100A. 2.1mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 5µm, Cogent RP C18™ Stationary Phase. They are double end capped ( fully ), with traditional bonding of an 18 carbon silane to the highest purity silica available. Designed to protect your 2.1mm ID, RP C18, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Microsolv Technology Corporation Guard Column Cartridges, RP C18, 5um, 100A. 4.0mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 5µm, Cogent RP C18™ Stationary Phase. They are double end capped ( fully ), with traditional bonding of an 18 carbon silane to the highest purity silica available. Designed to protect your 3.0, 4.0 or 4.6mm ID, RP C18, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Microsolv Technology Corporation Guard Column Cartridges, RP C18 ABX, 10um, 100A. 4.0mm ID x 10mm Length. 5/PK.
These Guard Column Cartridges are packed with 10µm, Cogent RP C18 ABX™ Stationary Phase. They are specially end capped ( bulky ), with traditional bonding of an 18 carbon ligand to the highest purity silica available.Designed to protect your 3.0, 4.0 or 4.6mm ID, RP C18 ABX, Analytical Columns from particulate and contaminants that will adsorb to it. They are packed in Stainless Steel Tubes and have Stainless Steel Frits that are pressed into PEEK Frit Caps. These Guard Column Cartridges must be used with a Guard Column Holder.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sepax Technologies Inc Sepax HPLC Column Proteomix SCX, NP10, Guard cartridge with holder, 4 x 10 mm
Proteomix ion-exchange phases have been innovatively developed for achieving high ion-exchange capacity, a breakthrough technology for non-porous resins. Proteomix packing support is composed of a rigid, spherical, highly cross-linked poly(styrene divinylbenzene) (PS/DVB) non-porous bead with particle size selections of 1.7, 3, 5 and 10 µm. The PS/DVB resin surface is grafted with a highly hydrophilic, neutral polymer thin layer with the thickness in the range of nanometer. The hydrophobic PS/DVB resin surface is totally covered by a hydrophilic coating that eliminates non-specific bindings with biological analytes, leading to high efficiency and high recovery separations for biological molecules.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sklar Instruments SKLAR INSTRUMENTS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
5000484513 NONVENT TIP GUARD CLR 3/16 X1
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sklar Instruments SKLAR INSTRUMENTS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
5000484512 NONVENT TIP GUARD CLR 5/64X3/4
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp XSelect CSH C18 Sentry Guard Cartridge, 130Å, 3.5 µm, 4.6 mm X 20 mm, 2/pk
XSelect CSH C18 columns can be used as general purpose columns that provide alternative selectivity compared to other C18 sorbents. Charged Surface Hybrid (CSH) technology helps you overcome column related problems such as peak shape asymmetry and poor loading for basic compounds, column bleed, and slow mobile-phase re-equilibration.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Phenomenex Inc Venusil 5m XBP Phenyl 100
Guard Cartridge 10 x 10mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Pickering Laboratories Inc REVERSE PHASE GUARD CART PK2
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
NC3449930 REVERSE PHASE GUARD CART PK2
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
ZEOCHEM SILICA MATERIAL INC GUARD PD 30X20MM 5 100 1/PK
GUARD PD 30X20MM 5 100 1/PK
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp XBridge BEH Amide VanGuard Cartridge, 130Å, 3.5 µm, 2.1 mm X 5 mm, 3/pk
XBridge BEH Amide VanGuard Cartridges are used to extend analytical column lifetime and performance by removing particulate contamination from the mobile phase stream. This cartridge is optimized to protect all 2.1 mm and 3.0 mm I.D. XBridge BEH Amide analytical columns containing 3.5 µm sorbent particles.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Phenomenex Inc Guard Column 30 x 4.6mm
Biozen™ 1.6um dSEC-1 Guard Column
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More