GC Capillary Columns
- (15)
- (1)
- (6)
- (1)
- (116)
- (1)
- (16)
- (1)
- (190)
- (2)
- (7)
- (2)
- (81)
- (1)
- (4)
- (1)
- (25)
- (1)
- (1)
- (13)
- (1)
- (8)
- (8)
- (90)
- (3)
- (1)
- (2)
- (95)
- (1)
- (1)
- (1)
- (98)
- (1)
- (9)
- (30)
- (11)
- (1)
- (1)
- (1)
- (31)
- (5)
- (1)
- (4)
- (1)
- (1)
- (3)
- (1)
- (1)
- (3)
- (1)
- (35)
- (14)
- (39)
- (20)
- (29)
- (1)
- (8)
- (22)
- (20)
- (5)
- (7)
- (34)
- (11)
- (7)
- (5)
- (17)
- (4)
- (9)
- (1)
- (10)
- (11)
- (3)
- (2)
- (1)
- (6)
- (9)
- (10)
- (30)
- (21)
- (13)
- (19)
- (1)
- (1)
- (1)
- (7)
- (13)
- (14)
- (1)
- (129)
- (123)
- (1)
- (143)
- (1)
- (13)
- (30)
- (40)
- (21)
- (1)
- (69)
- (20)
- (72)
- (29)
- (8)
- (22)
- (6)
Filtered Search Results
Thermo Scientific™ TraceGOLD TG-35MS GC Columns
Use these columns for a higher phenyl content that provides useful elution order and retention time changes.
| Max. Temperature | 300/320°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-35 MS |
| Polarity | Mid-Polar |
| USP Type | G42 |
Thermo Scientific™ TraceGOLD TG-17MS GC Columns
Use these columns for GCMS applications that require more polarity than a 5% phenyl column.
| Max. Temperature | 300/320°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-17 MS |
| Polarity | Mid-Polar |
| USP Type | G43 |
Thermo Scientific™ TraceGOLD TG-5SilMS GC Columns
Incorporates phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation.
| Max. Temperature | 330/350°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 SilMS |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS Applications Using Ion-Trap Systems,GC/MS for Polycyclic Aromatics, Phthalates, Phenols, Amines, and Organophosphates,GC/MS for Hydrocarbons Including Chlorinated Hydrocarbons |
| USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD TG-VRX GC Columns
Thermo Scientific™ TraceGOLD TG-VRX GC Columns provide good resolution and fast analysis times for volatile compounds.
| Max. Temperature | 260°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-VRX |
| Polarity | Non-Polar |
Thermo Scientific™ TraceGOLD TG-VMS GC Columns
Thermo Scientific™ TraceGOLD TG-VMS GC Columns provide good resolution and fast analysis times for volatile compounds.
| Max. Temperature | 260°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-VMS |
| Polarity | Non-Polar |
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
| Max. Temperature | 340/360°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-XLBMS |
| Polarity | Low-Polar |
Thermo Scientific™ TraceGOLD TG-POLAR GC Columns
Redefine your expectations for high-polarity GC columns with the Thermo Scientific TraceGold TG-POLAR Columns
| Max. Temperature | 260/275°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-Polar |
| Polarity | Highly Polar |
| USP Type | G8, G48 |
Thermo Scientific™ TraceGOLD TG-1701MS GC Columns
Features a mix of cyano and phenyl groups for increased polarity and a different elution order relative to less polar columns.
| Max. Temperature | 260/280°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-1701 MS |
| Polarity | Mid-Polar |
| USP Type | G46 |
Thermo Scientific™ TraceGOLD TG-1301MS GC Columns
Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.
| Max. Temperature | 260/280°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-1301 MS |
| Polarity | Mid-Polar |
| USP Type | G43 |
Thermo Scientific™ TraceGOLD TG-5HT GC Columns
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
| Max. Temperature | 380/400°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 HT |
| Polarity | Low-Polar |
| For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
| USP Type | G27, G36 |
| Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD TG-ALC1 GC Columns
Analyze blood alcohols with this ultra-low bleed column for enhanced sensitivity and reproducibility
| Max. Temperature | 260°C |
|---|---|
| Length (Metric) | 30 m |
| Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD TG-200MS GC Columns
Exceptionally inert mid-polarity columns with selectivity and elution order optimized for difficult separations
| Max. Temperature | -20°C to +320/340°C |
|---|---|
| Type | GC Capillary Column |
| Diameter (Metric) Inner | 0.15 mm |
| For Use With (Application) | Silica Analysis |
| Film Thickness | 0.15 μm |
Thermo Scientific™ TraceGOLD™ TG-200MS GC Columns
Resolve compounds that phenyl and cyano phases cannot using a low-bleed GC column with an exceptionally inert phase.
| Max. Temperature | 320/340°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-200 MS |
| Polarity | Mid-Polar |
| USP Type | G6 |
Thermo Scientific™ TraceGOLD™ TG-PAH GC Columns
Use these thermally stable TraceGOLD TG-PAH GC columns for fast analysis of regulated polycyclic aromatic hydrocarbons (PAHs) in complex food and environmental samples.
| Stationary Phase | TraceGOLD™ PAH |
|---|---|
| For Use With (Application) | Gas Chromatography (GC) |
| Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Columns
Thermo Scientific™ TraceGOLD TG-5MS AMINE GC Column enables analysis of ppm levels of amines without column priming.
| Max. Temperature | 300/315°C |
|---|---|
| Stationary Phase | TraceGOLD™ TG-5 MS Amine |
| Polarity | Low-Polar |
| For Use With (Application) | GC/MS for Analysis of Amines and Other Basic Compounds, Including Alkylamines, Diamines, Triamines, and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |