pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
Ohaus™ Starter ST20M-C Multi-Parameter Pen Meter
Compact design for fast, convenient electrochemistry reading. Measure conductivity, pH, temperature and salinity with the same meter. IP67, automatic temperature compensation, 3-point calibration and auto-off after 6 minutes of non-use
METTLER TOLEDO™ Portable pH/Conductivity/Dissolved Oxygen/Ion Meters
Water and dust proof, IP67 rated meter for portable or field measurements. Portable meters compatible with pH, conductivity, dissolved oxygen, and ion selective electrodes.
| IP Rating | IP67 |
|---|---|
| Certifications/Compliance | ISO 9001:2000 |
Mettler Toledo™ pH/Conductivity/DO Meter NineFocus™ NF2340™
High-performance, multiparameter benchtop meter for compelling precision in pH, conductivity, ion concentration, redox, and dissolved oxygen determinations.
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
Fisherbrand™ accumet™ Gel-Filled Polymer Body pH/ATC Double-Junction Combination Electrodes: Mercury-Free
Combine the convenience of a combination electrode with built-in ATC probe
| Type | pH/ATC Combination Electrode |
|---|---|
| Length (Metric) Cable | 0.10 m |
| Length (Metric) | 106 mm |
| Temperature (English) Operating | 23°F to 176°F |
| pH Range | 0 to 14 |
| Color | Purple |
| Length (English) | 4 in. |
| Length (English) Cable | 30 in. |
| Filling Solution Type | Gel |
| Material | Epoxy |
| Junction | Double |
| Temperature (Metric) Operating | -5°C to +80°C |
| Internal Reference | Ag/AgCl |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/LogR™ Benchtop Meter
Get premium performance and ultimate flexibility with our benchtop meter with pH/LogR module for pH, mV, ORP and LogR temperature technology.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH with LogR Temperature,mV,Relative mV,ORP with Temperature |
| Range (pH) | -2 to 20 |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | LCD, Color Graphic with User-Customizable Options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration, 3 point LogR temperature calibration |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 or ±0.05%, whichever is greater |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic with Auto-Read, Timed, and Single-shot Measure Modes, Manual |
| Calibration | pH with calibration editing option, relative mV, ORP, LogR temperature and temperature |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS-232 |
| Range (Relative mV) | ±2000.0mV |
| Backlight Option | Yes |
| Temperature Range (English) | 22.0°F to 221.0°F |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
| Methods | 10 per channel |
| Range (ORP) | ±2000.0mV |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Mettler Toledo™ FiveGo™ F2 pH/mV Meters
Portable meter provides reliable and high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | 200 measurements, current calibration |
| Log Function Type | Automatic, Manual |
| Measurement Modes | pH |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Calibration Points | 3 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 18.8 x 7.7 x 3.3 cm (97.4 x 3 x 1.3 in.) |
| Display Type | LCD |
| Model | F2 |
| Resolution (mV) | 1mV |
| Data Points | 200 |
| Backlight Option | None |
| Weight (English) | 0.5 lb. |
| Resolution (Temperature) | 0.1° |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | -1999 to 1999 |
| Inputs | BNC, Cinch |
| Accuracy (Temperature) | ±0.5°C |
| Weight (Metric) | 0.26 kg |
Mettler Toledo™ pH/Conductivity Meter NineFocus™ NF2300™
High-performance, multiparameter benchtop meter for compelling precision in pH, conductivity, ion concentration, redox, and dissolved oxygen determinations. The modular meter is at its best with the smart digital InLab™ DES™ sensors.
| Length (Metric) | 40 cm |
|---|---|
| Memory | 3000 Result Sets |
| Languages | Chinese Simplified, Chinese Traditional, English, French, German, Italian, Polish, Portuguese, Russian, Spanish, Thai, Turkish |
| Measurement Modes | pH with mV and Temperature,Conductivity,Dissolved Oxygen |
| Width (Metric) | 30 cm |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | 0.002 |
| Accuracy | -30 to 130°C |
| Data Management Details | PC, Printer, USB stick |
| Display Type | Color TFT (7 in.) |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | 0.5 % |
| Resolution (mV) | 0.1,1 |
| Data Points | 2000 |
| Calibration Modes | Calibration Support, Guided verification, Multilingual Menu, Simple Methods, Touch screen |
| Certifications/Compliance | CE, WEEE, RoHS |
| Weight (Metric) | 2 kg |
| Height (Metric) | 34 cm |
| Accuracy (mV) | 0.1 |
| Temperature Accuracy | ±0.1°C between 0°C and 100°C |
| Resolution (Conductivity) | 0.001 to 0.1 |
| Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
| Log Function Type | Automatic by Interval or Event, Manual |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Dimensions (L x W x H) | 40 x 30 x 34 cm |
| Product Type | pH/Conductivity Meter |
| IP Rating | IP52 |
| Range (Relative mV) | -2000 to 2000 mV |
| Backlight Option | Yes |
| Temperature Range (Metric) | -30°C to +130°C |
| Temperature Resolution | 0.1°C |
Mettler Toledo™ FiveEasy™ F30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
| Resolution (Conductivity) | Automatic range |
|---|---|
| Memory | Current calibration |
| Range (Conductivity) | 0.01 μS/cm to 200 mS/cm |
| Range (TDS) | 0 mg/L to 300 mg/L |
| Measurement Modes | Conductivity |
| Calibration | One point calibration with three predefined standards |
| Range (Salinity) | 0 to 42 psu |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
| Display Type | LCD |
| Voltage | 100/240 V |
| Accuracy (Conductivity) | ±0.5% of the measured value |
| Model | F30 |
| Frequency | 50/60Hz |
| Data Points | 200 |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | -5°C to +105°C |
| Inputs | Mini-DIN |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Thermo Scientific™ Orion Star T940 All-in-One Titrator and Kits
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated all-in-one titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
| Titration Technique | Equivalence point or preset endpoint |
|---|---|
| Memory | Non-volatile memory preserves data logs and settings |
| Advanced ISE Functions | Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette |
| Resolution (pH) | 0.001, 0.01, 0.1 (user selectable) |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
| Data Management Details | Data log export as CSV or PDF file, short or long format |
| Display Type | 5.7 in. color capacitive touchscreen, 640 x 480 resolution |
| Functions Available | Sample titration, titrant standardization, calibration and direct measure |
| Resolution (mV) | 0.1 mV |
| Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
| Temperature Probe Calibration | Optional 1 point offset calibration |
| Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
| Probe Type | pH electrode, redox electrode or ion selective electrode (ISE); reference half-cell electrode; ATC temperature probe; stirrer probe |
| Accuracy (mV) | ±0.2 mV |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading, whichever is greater |
| Titrant Determination | Standardization titration or manual concentration input |
| Warranty | 1 year replacement warranty |
| Calibration Points (ISE) | 1 to 5 |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 10 x 16 x 14 in. (25.4 x 40.6 x 35.6 cm) |
| Temperature Selection | Manual or automatic |
| Precision | 0.5% RSD, dependent on environment and handling conditions |
| Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes, adjustable |
| Range (mV) | -2000.0 to +2000.0 mV |
| Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
| Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
| Titration Process Control | Routine, quick, careful or user defined |
| Time and Date | Yes, with nonvolatile battery backup |
| Updateable Firmware | Yes, using USB flash drive |
| Range (pH) | -2 to 20 |
| For Use With (Application) | Acid-base titrations, redox titrations, ion concentration titrations |
| Titration Types | Direct or back titration |
| Channels | 1 |
| Accuracy (pH) | ±0.002pH |
| Range (ISE) | 0.0001 to 19990 |
| Titration Setup Wizard | Yes, using Start a New Titration workflow |
| Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
| Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
| Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
| Inputs | BNC (pH, redox or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
| Accuracy (Temperature) | ±0.2 °C |
| Equivalence Points | 1 to 2 |
| Electrical Requirements | 100-240V, 50/60 Hz |
| Temperature (English) Operating | 41°F to 104°F |
| Preset Endpoints | 1 to 3 |
| Material | ABS Plastic |
| Calibration | pH, mV, ion concentration (ISE) and temperature |
| Calibration Points | 1 point relative mV (RmV) mode |
| Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
| IP Rating | IP51 |
| Model | Orion Star T940 |
| Sample ID | Auto-incremental, manual or off |
| Resolution (Temperature) | 0.1 °C |
| Temperature Range (Metric) | -5.0°C to +100.0°C |
| Temperature (Metric) Operating | 5°C to 40°C |
| Blank Options | Fixed value or variable value using titration |
Fisherbrand™ accumet™ Metallic ORP Combination Electrode - Mercury - Free, Ag/AgCl Reference; BNC Connector
Platinum Pin Ag/AgCl Combination electrode for environmental ORP measurements
| Temperature (Metric) Range | -5°C to +100°C |
|---|---|
| Filling Solution Type | SP135-500 |
| Material | Glass |
| For Use With (Application) | Environmental ORP measurements |
| Temperature (Metric) Operating | -5°C to +100°C |
| Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ Liquid-Filled Polymer Body Combination Electrodes: Mercury-Free
Ideal for measurements in small vessels or with small samples
| Diameter (English) | 0.4 in. |
|---|---|
| Type | Combination pH Electrode |
| Temperature (Metric) Range | -5°C to +100°C |
| Length (Metric) | 106 mm |
| Temperature (English) Operating | 23°F to 212°F |
| pH Range | 0 to 14 |
| Diameter (Metric) | 10 mm |
| Length (English) | 4.1 in. |
| Material | Polypropylene |
| For Use With (Application) | For measurements in small vessels or with small samples |
| Temperature (Metric) Operating | -5°C to +100°C |
| Internal Reference | Ag/AgCl |