| Titration Technique |
Equivalence point or preset endpoint |
| Memory |
Non-volatile memory preserves data logs and settings |
| Advanced ISE Functions |
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette |
| Resolution (pH) |
0.001, 0.01, 0.1 (user selectable) |
| Languages |
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
| Resolution (ISE) |
0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Cycles Per Titration Run |
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
| Data Management Details |
Data log export as CSV or PDF file, short or long format |
| Display Type |
5.7 in. color capacitive touchscreen, 640 x 480 resolution |
| Functions Available |
Sample titration, titrant standardization, calibration and direct measure |
| Resolution (mV) |
0.1 mV |
| Data Points |
100 data sets each: sample titration, titrant standardization, calibration and direct measure |
| Temperature Probe Calibration |
Optional 1 point offset calibration |
| Certifications/Compliance |
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
| Probe Type |
pH electrode, redox electrode or ion selective electrode (ISE); reference half-cell electrode; ATC temperature probe; stirrer probe |
| Accuracy (mV) |
±0.2 mV |
| Accuracy (ISE) |
±0.2 mV or ±0.05% of reading, whichever is greater |
| Titrant Determination |
Standardization titration or manual concentration input |
| Warranty |
1 year replacement warranty |
| Calibration Points (ISE) |
1 to 5 |
| Relative Humidity Range |
5 to 85%, non-condensing |
| Dimensions (L x W x H) |
10 x 16 x 14 in. (25.4 x 40.6 x 35.6 cm) |
| Temperature Selection |
Manual or automatic |
| Precision |
0.5% RSD, dependent on environment and handling conditions |
| Outputs |
3 USB ports for printer, USB flash drive and computer software connections |
| Calibration Points (pH) |
1 to 5 |
| Backlight Option |
Yes, adjustable |
| Range (mV) |
-2000.0 to +2000.0 mV |
| Methods |
Up to 10 methods with optional password protection; import/export methods via USB flash drive |
| Resolution |
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
| Titration Process Control |
Routine, quick, careful or user defined |
| Time and Date |
Yes, with nonvolatile battery backup |
| Updateable Firmware |
Yes, using USB flash drive |
| Range (pH) |
-2 to 20 |
| For Use With (Application) |
Acid-base titrations, redox titrations, ion concentration titrations |
| Titration Types |
Direct or back titration |
| Channels |
1 |
| Accuracy (pH) |
±0.002pH |
| Range (ISE) |
0.0001 to 19990 |
| Titration Setup Wizard |
Yes, using Start a New Titration workflow |
| Stirrer Probe Speeds |
5 user selectable speeds (250 to 3700 RPM) |
| Burette Sizes |
10 mL, 20 mL (included) or 50 mL |
| Burette Functions |
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
| Inputs |
BNC (pH, redox or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
| Accuracy (Temperature) |
±0.2 °C |
| Equivalence Points |
1 to 2 |
| Electrical Requirements |
100-240V, 50/60 Hz |
| Temperature (English) Operating |
41°F to 104°F |
| Preset Endpoints |
1 to 3 |
| Material |
ABS Plastic |
| Calibration |
pH, mV, ion concentration (ISE) and temperature |
| Calibration Points |
1 point relative mV (RmV) mode |
| Alarm Output |
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
| IP Rating |
IP51 |
| Model |
Orion Star T940 |
| Sample ID |
Auto-incremental, manual or off |
| Resolution (Temperature) |
0.1 °C |
| Temperature Range (Metric) |
-5.0°C to +100.0°C |
| Temperature (Metric) Operating |
5°C to 40°C |
| Blank Options |
Fixed value or variable value using titration |