Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Power Supply | Universal AC adapter (included) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6 mmHg |
| Range (ORP) | ±2000.0 mV |
| Pressure Resolution | 0.1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Thermo Scientific™ Orion Star™ A324 pH/ISE Portable Multiparameter Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Accurately monitor pH, ion concentration, mV, ORP and temperature with our pH/ISE portable meter for challenging field testing.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A324 pH/ISE/mV/RmV/ORP/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A123 Dissolved Oxygen Portable Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Take simple dissolved oxygen and temperature measurements with this portable meter with easy operation for basic field testing.
| Temperature (Metric) Range | 0.0°C to 50.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 450 to 850mmHg (manual entry) |
| Memory | Non-volatile memory preserves log and settings |
| Languages | English |
| Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Channels | 1 |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 450 to 850mmHg, automatic with manual entry |
| Battery Life | 2000 hours |
| Data Management Details | Internal data point memory |
| Display Type | LCD |
| Data Points | 50 |
| Calibration Modes | Water-saturated air, manual (Winkler titration) |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | 9 pin MiniDIN (polarographic DO sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Salinity Factor | 0 to 45 ppt, automatic correction using manual entry of sample salinity |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter Warranty |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Sensor Types | Polarographic Dissolved Oxygen Sensor |
| Percent Saturation Range Polarographic DO | 0.0 to 200.0 % saturation |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Battery Type | Four AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
| IP Rating | IP-67 |
| Temperature Selection | Automatic with ATC temperature probe |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Keypad | Simple with highlighted measure key, scroll and shortcut keys |
| Outputs | None |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Range (Polarographic DO) | 0.00 to 20.00 mg/L |
| Percent Saturation Range (Polarographic DO) | 0.0 to 200.0 % saturation |
Mettler Toledo™ Seven2Go S7 Conductivity Meter
The Seven2Go portables are engineered to provide users with fast quality data, one-handed operation, and durability, making them ideally suited for mobile applications in the laboratory, at-line, and outdoors.
| Range (Resistivity) | 0.00 to 100.0 Mohm/cm |
|---|---|
| Measurement Modes | Conductivity |
| Cell Constant | Manual entry |
| Range (pH) | 0 to 14 |
| Channels | 1 |
| Range (Salinity) | 0.00 to 42 psu |
| Temperature Compensation | Automatic or Manual |
| Battery Life | 200 to 250 hr. |
| Display Type | Color Graphic |
| Accuracy (Salinity) | ±0.5% |
| Resolution (Salinity) | 0.01 to 0.1 |
| Accuracy (Conductivity) | ±0.5% |
| Certifications/Compliance | ISO 9001:2000 |
| Inputs | LTW 7-pin (sensor) |
| Weight (Metric) | 290 g |
| Resolution (Conductivity) | 0.01 |
| Range (Conductivity) | 0.01 μS/cm to 1000 mS/cm |
| Range (TDS) | 0.01 mg/L to 600 g/L |
| Resolution (TDS) | 0.01 to 1 |
| Battery Type | 4 x 1.5 V AA or 1.3 V NiMH acc. |
| Calibration Points | 1 |
| Dimensions (L x W x H) | 222 x 70 x 35 mm |
| Accuracy (TDS) | ±0.5% |
| IP Rating | IP67 |
| Model | Single channel; conductivity, TDS, salinity |
| Temperature Range (Metric) | -5°C to +105°C |
Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.
| Salinity Measurement Modes | Natural Seawater (ppt) or Practical Salinity (PSU) |
|---|---|
| Memory | Non-volatile |
| Cell Constant | 0.100 to 10.00 cm-1 |
| Measurement Modes | Conductivity with Temperature,Salinity with Temperature,TDS with Temperature |
| Temperature (Metric) Reference | 15.0, 20.0, 25.0 or 30.0°C |
| Temperature Coefficient | 0 to 10 %/°C |
| TDS Factor Range | 0.40 to 1.00 |
| Range (Salinity) | 0.00 to 80.0 ppt; 0.00 to 42.0 PSU |
| Data Management Details | Continuous, Auto-Read and Timed read modes |
| Temperature Compensation | Linear (0 to 10 %/°C) or off |
| Display Type | 5 in. backlit LCD |
| Accuracy (Salinity) | ±0.5 % of the reading ± 1 LSD |
| Resolution (Salinity) | 0.01, 0.1 ppt; 0.01, 0.1 PSU |
| Accuracy (Conductivity) | ±0.5 % of the reading ± 1 LSD |
| Data Points | 500 Sets with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | 8-pin MiniDIN for conductivity with built-in ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 700 grams |
| Calibration Points (Conductivity) | 1-5 points conductivity |
| Warranty | 3 year meter warranty |
| Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
| Range (Conductivity) | 0.00 μS to 500.0 mS |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
| Calibration | Conductivity, salinity, TDS and temperature |
| Calibration Points | 1 point salinity, 1-5 points TDS, 1 point temperature |
| Alarm Output | Calibration reminder alarm |
| Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
| Accuracy (TDS) | ±0.5 % of the reading ± 1 LSD |
| IP Rating | IP54 |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Outputs | Computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | 23.0°F to 221.0°F |
| Weight (English) | 1.54 lb. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Compatible Probes | 2-cell and 4-cell conductivity electrodes |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE Benchtop Multiparameter Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Get premium performance and ultimate flexibility with our benchtop meter with pH/ISE module for pH, ion concentration, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP54 |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For the ultimate flexibility, combine the Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Without Modules with up to four measurement modules to build your ideal system.
Mettler Toledo™ Expansion Module for SevenExcellence™ DO/BOD Meters
For use with SevenExcellence Dissolved Oxygen and DO/BOD Meters.
Mettler Toledo™ pH/Conductivity/DO Meter NineFocus™ NF2340™
High-performance, multiparameter benchtop meter for compelling precision in pH, conductivity, ion concentration, redox, and dissolved oxygen determinations.
OHAUS™ Starter TDS Pen Meter With Temperature Display
TDS meters with a temperature display. OHAUS Starter TDS Pen Meter provides reliable and accurate measurement of TDS in a portable and compact design. Combined content of all organic and inorganic substances in a liquid can also be measured.
OHAUS™ StarterTDS Pen Meters
TDS meters without temperature display. OHAUS Starter TDS Pen Meters have durable IP67 waterproof design and provides fast, straightforward results.
Mettler Toledo Titrator Karl Fischer EVA C1 X
A cutting-edge (EVA C1 X) solution designed for precise and efficient trace water determination across diverse sample types
Mettler Toledo Titrator Karl Fischer EVA C1 D
A cutting-edge solution designed for precise and efficient trace water determination across diverse sample types
Thermo Scientific™ Elite CTS Conductivity / TDS / Salinity Pin-sensor Pocket Testers and Replacement Sensors
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Flexible on-the-go conductivity, TDS, salinity and temperature testing using durable Elite CTS pin-sensor pocket testers for a variety of applications including hydroponics, pools, spas and more!
| Salinity Measurement Modes | Per practical salinity curve |
|---|---|
| Temperature Accuracy | ±0.6°C, ±1.0°F for 0.0 to 50.0°C; ±1.1°C, ±1.9°F for 50.1 to 60.0°C |
| Resolution (Conductivity) | 0.1 μS/cm for 0.0 to 200.0 μS/cm; 1 μS/cm for200 to 2000 μS/cm; 0.01 mS/cm for 2.00 to 20.00 mS/cm |
| Range (Conductivity) | 0.00 to 20.00 mS/cm |
| Range (TDS) | 0.00 to 10.00 ppt |
| Measurement Modes | Conductivity,TDS,Salinity,Temperature |
| Resolution (TDS) | 0.1 ppm for 0.0 to 100.0 ppm; 1 ppm for 100 to 1000 ppm; 0.01 ppt for 0.10 to 10.00 ppt |
| TDS Factor Range | 0.40 to 1.00 (selectable) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (Salinity) | 0.00 to 10.00 ppt |
| Temperature Compensation | Yes |
| Accuracy (TDS) | ± 1% full scale |
| Accuracy (Salinity) | ± 1% full scale |
| Resolution (Salinity) | 0.10 ppt |
| Accuracy (Conductivity) | ± 1% full scale |
| Temperature Range (English) | 32.0°F to 140.0°F |
| Temperature Probe Calibration | 1 point |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Resolution | 0.1°C, 0.1°F |
| Calibration Points (Conductivity) | 1 to 3 |
Ohaus™ Starter ST20M-C Multi-Parameter Pen Meter
Compact design for fast, convenient electrochemistry reading. Measure conductivity, pH, temperature and salinity with the same meter. IP67, automatic temperature compensation, 3-point calibration and auto-off after 6 minutes of non-use