Benchtop Titrator Accessories
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (5)
- (2)
- (1)
- (6)
- (1)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
Filtered Search Results
| Description | Thermo Printer and Accessories |
|---|
For use with Metrohm KF Titrators.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA Septum 16 mm, Set of 5 pieces
Septum 16 mm, 5 pieces. Height 2mm; Material: Silicone rubber; Outer diameter 16mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA SAMPLE VIAL 6.2419.000 6ML
Sample vial 6 mL / 100 vials per pack. Suitable for the 6.1448.05X septum. Utilization for KF determinations with oven.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA Thermal paper for Custom Neos-N / Q3X. TID 0008FaK78UFR34WD
Thermal paper for Custom Neos-N / Q3X. TID 0008FaK78UFR34WD
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
METTLER TOLEDO 3P INDUSTRIAL SILVER RING SENSOR DMI141 SC
NC2455685 SILVER RING SENSOR DMI141 SC
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
METROHM USA SAMPLE BEAKER 120ML/250 PIECES
NC0239851 SAMPLE BEAKER 120ML/250 PIECES
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA METROHM O-RINGS, PACKAGE OF 6
Set of seals for 6.1414.030. The set is comprised of one seal and various O-rings.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA THERMAL PAPER 756 SINGLE ROLL
Sufficient for approx. 10'000 printed lines. For 756 Coulometer
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
BURKLE INC Bottle holder, bottles up to Ø 3.46 in. (88 mm), TeleScoop
Holds all bottles up to 88 mm (3.46 in.) Ø. Plastic, glass or metal bottles can be securely filled in this way. Angle steplessly adjustable up to 90°.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA ECOTRODE GEL
Maintenance-free pH electrode for routine use
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
METTLER TOLEDO 3P INDUSTRIAL RONDO DISPENSING TUBE 1.35 M
The Karl Fischer Kit for Rondo 60 transforms a standard Rondo 60 within minutes into a sample changer for Karl Fischer Titrations. The conversion can be accomplished by the user himself and does not need special tools or knowledge. after the conversion, the system allows the automation of up to 20 samples in combination with a Karl Fischer capable DL5x or DL7x titrator. The samples are processed the following way: 1. Samples are filled into the special glass beakers. 2. The beakers are tightly closed with an aluminium lid and a rubber ring. 3. Before titration, the KF head of Rondo 60 pinches through the lid, fills in the methanol. 4. after mixing with the magnetic stirrer, the sample is titrated. The system allows highly precise measurements of water contents down to 100 ppm. The conversion back into a standard Rondo 60 is possible anytime.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Metrohm USA SOLVOTRODE EASYCLEAN
The space-saving electrode for titration in nonaqueous media with easyClean diaphragm. Diaphragm: Ground-joint diaphragm; Electrode plug-in head: Fixed cable (l = 1 m) with plug F; Electrode slope: > 0.90; Electrode zero point (mV): 0-100 mV (pH = 7); Electrolyte flow rate (ul/h): 3-50; Indicator electrode shape: Sphere; Indicator electrode type: Glass electrode; Internal reference electrode type: LL system; Measuring range: 0-14; Measuring unit: pH; Membrane glass type: T; Membrane resistance: 50-150; Min. immersion depth (mm): 20; Plug for filling opening: Orifice; Reference electrolyte type: LiCl(sat) in ethanol; Reference system: LL system; Resistance (kOhm): <250; SGJ sleeve: flexible SGJ sleeve; Shaft diameter bottom (mm): 12; Shaft diameter top (mm): 12; Shaft material: Glass; Temperature range, long-term (C): 0-70; Temperature range, short-term (C): 0-70.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More