Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (78)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (2)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
Cytiva Whatman™ Nuclepore™ Polycarbonate Hydrophilic Membranes
Suitable for a wide range of sample types and applications including bioassays, cell biology, and environment analysis
Cytiva Whatman™ 0.8 μm Pore Size (ME 27) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 27) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.8 μm |
|---|---|
| Bubble Point | 1.3 bar |
| Flow Rate | 2.8 sec./100 mL/12.5 cm⊃ (at Δp = 0.9 bar) |
| Material (Membrane) | ME 27 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 11.6 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ Nitrocellulose Membrane Filters
Recommended for the majority of routine applications, manufactured under strictly controlled conditions
Cytiva Whatman™ Anodisc™ Filter Membranes
Constructed with precision pore structure and narrow pore size distribution. Whatman™ Anodisc™ Filter Membranes ensure a high level of particle removal efficiency. Captures microorganisms and particulates on the surface of the membrane for subsequent analysis.
| Material | Aluminum Oxide |
|---|
Cytiva Whatman™ WTP Range PTFE Membranes
Suited for applications involving aggressive organic solvents, strong acids, and alkalis due to being chemically stable and inert. Whatman™ WTP Range PTFE Membranes are particularly suitable for preparing samples for HPLC analysis, air and gas sterilization.
| Quantity | 100 Pack |
|---|---|
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| Sterility | Non-sterile |
| Membrane Type | WTP |
Cytiva Whatman Cyclopore Polycarbonate Membrane
Featuring sharp cut-off and reproducible microfiltration characteristics of track-etched membrane filters
| Material | Polycarbonate |
|---|
Cytiva Life Sciences™ Sentino Membrane Dispenser Refill ME25
Gridded, ME25 mixed cellulose ester membranes.
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 0.8μm
Membrane Filters for Colony Counting, Particle Testing and Microscopy - Cellulose nitrate (cellulose ester), gridded, individually, sterile packaged
| Pore Size | 0.8 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Sterile |
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 35.5 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| No. per Case | 100Pack |
| Quantity | 100/Pk. |
| Material | Nylon |
| Filter Type | Screen Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Clarifying aqueous or organic solutions prior to HPLC analysis. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 0.65μm
Membrane Filters for Colony Counting, Particle Testing and Microscopy - Cellulose nitrate (cellulose ester), gridded, individually, sterile packaged
| Pore Size | 0.7 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Sterile |
Cytiva Nucleus Membrane
Made from polycarbonate film, for precision analysis of track-etched manufacturing
| Type | Nucleus Membrane |
|---|---|
| Material | Polycarbonate |
| For Use With (Application) | Air Analysis, Bioassay, Cell Biology, Environmental Analysis, Epi-Fluorescence Microscopy, EPA Test, Fuel Test, Parasitology, and Underwater Microbiology |
Cytiva Whatman™ Nuclepore Hydrophilic Membrane
Nuclepore track-etched hydrophilic membranes with highly defined pore size cutoff in sub-micron range
| Type | Nuclepore hydrophilic membrane |
|---|---|
| Material | Polycarbonate |
| For Use With (Application) | Bioassays, Cell biology, Environmental analysis, Microscopy, Cytology, Parasitology, Certain air and oceanography analyses |
Sartorius Microsart™ e.motion Membrane Filters
For colony counting, particle testing and microscopy. Specifically designed for use in the Microsart™ e.motion dispenser, the filters are individually sterile-sealed in a format packaged on a pleated band, without protective paper. Can also be used with Sartorius nutrient pad sets.
Sartorius Regenerated cellulose (RC) Membrane Filters
These solvent-resistant, hydrophilic membrane filters are excellently suited for particle removal from solvents.
| Thickness (Metric) | 160 to 200 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material | Regenerated Cellulose |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For particle removal from solvents. |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
Sartorius Microsart™ e.motion Membrane Filters
For colony counting, particle testing and microscopy. Specifically designed for use in the Microsart™ e.motion dispenser, the filters are individually sterile-sealed in a format packaged on a pleated band, without protective paper. Can also be used with Sartorius nutrient pad sets.