Filtration Membrane Discs
Thin, precut membrane rounds for high-throughput, fast filtration of liquid and gas samples. Gridded and non-gridded discs. Various materials including mixed cellulose ester, polycarbonate, PTFE, nylon, and PVDF. For air monitoring/analytical research.
Sizes
Filter membranes are made in a range of diameters, typically designed to fit a specific holder or manifold.
Materials
Filter membrane can be made from cellulose, mixed cellulose esters (MCE), polyvinylidene fluoride (PVDF), polyethersulfone (PES), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), nylon, polycarbonate (PC), polyester, polyethylene terephthalate (PET), and polypropylene (PP). Other membrane materials include aluminum oxide, gelatin, porcelain, and glass.
Pore Size
The size of membrane pores determines which particles will be retained by the filter. A pore size of 0.2 µm is small enough to remove microbes from solutions; a 0.45 µm ore size can remove larger particulates.
Color and Grids
White membrane filters may be plain or marked with square grids (outlined in black) that can help with enumerating particles. Gridded or plain black membrane filters may be helpful when filtering light-colored particulates.
Sterility
Filter membranes may be pre-sterilized or may be sterilized using ethylene oxide, gamma irradiation, or autoclaves. The need for sterility is determined by the application, which are many and varied:
- Light microscopy samples
- Cytology sample preparation
- Electron microscopy samples
- Air quality and other environmental monitoring
- Water analysis and water quality testing
- Microbiology colony counting and quality control
- Chemotaxis
- Sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids
- (11)
- (1)
- (5)
- (99)
- (8)
- (150)
- (9)
- (1)
- (8)
- (4)
- (6)
- (194)
- (1)
- (3)
- (22)
- (76)
- (185)
- (51)
- (126)
- (1)
- (1)
- (46)
- (14)
- (95)
- (18)
- (2)
- (22)
- (26)
- (6)
- (1)
- (4)
- (3)
- (4)
- (4)
- (11)
- (18)
- (8)
- (55)
- (145)
- (62)
- (3)
- (40)
- (225)
- (46)
- (18)
- (28)
- (8)
- (111)
- (31)
- (20)
- (55)
- (1)
- (32)
- (2)
- (13)
- (4)
- (1)
- (16)
- (1)
- (6)
- (25)
- (28)
- (1)
- (1)
- (2)
- (80)
- (5)
- (1)
- (1)
- (36)
- (1)
- (1)
- (810)
- (146)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (389)
- (309)
- (6)
- (3)
- (134)
- (633)
- (59)
Filtered Search Results
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters: 0.2μm
Ensure quality control in routine microbiological filtering. Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters, 0.2μm are single-packed membranes with black grids for colony counting, particle testing and microscopy. The 0.2μm pore size is BCT validated. Choose from two diameters and packaging quantities.
| Pore Size | 0.2 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Color | White |
| Grid Color | Black |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Sterile |
Sartorius Microsart™ e.motion Membrane Filters
Membrane Filters suitable for use in the Microsart e.motion dispenser
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.2μm Pore Size
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.2 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Color | White |
| Grid Color | Black |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Sterility | Non-sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.45μm Pore Size
The Nonsterile Membrane Filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.45 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For Colony Count, Sterility Testing, Particle Count, Microscopy |
| Sterility | Non-sterile |
Sartorius Gridded Nonsterile Cellulose Nitrate Membrane Filters: 0.65μm Pore Size
The non-sterile membrane filters are made of cellulose nitrate (cellulose mixed ester), cellulose acetate or regenerated cellulose. They can be used for colony counting, particle testing and microscopy. Choose between gridded or non-gridded, membranes, either with or without hydrophobic edge.
| Pore Size | 0.7 μm |
|---|---|
| Disposable | Single-use |
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Quantity | 100/Pk. |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| For Use With (Application) | For colony count; sterility testing; particle count; microscopy |
| Sterility | Non-sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 0.65 μm
MF-Millipore™ Membrane Filter composed of mixed cellulose esters (MCE) membrane, hydrophilic.
| Pore Size | 0.65 μm |
|---|---|
| Disposable | Reusable |
| Flow Rate | 140 mL/min. x cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Format | Disc |
| Color | White |
| Material | MCE |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
Sartorius Gridded Sterile Cellulose Nitrate Membrane Filters
Membrane Filters for Colony Counting, Particle Testing and Microscopy - Cellulose nitrate (cellulose ester), gridded, individually, sterile packaged
| Disposable | Single-use |
|---|---|
| Type | Membrane Filter |
| Format | Disc |
| Material (Membrane) | Cellulose Nitrate |
| Color | White |
| Material | Cellulose Nitrate |
| Filter Type | Membrane Filter |
| Hydrophobicity | Hydrophilic |
| Sterility | Sterile |
MilliporeSigma™ MF-Millipore™ Membrane Filter, 1.2 μm, Gridded
Mixed cellulose esters (MCE) membrane, hydrophilic
| Pore Size | 0.8 μm |
|---|---|
| Type | Membra Clear Membrane |
| Material | MCE |
| No. per Pack | 100Pack |
| Thickness (Metric) | 190 μm |
|---|---|
| Pore Size | 1.2 μm |
| Bubble Point | ≥0.4 bar, air with water |
| Flow Rate | Avg. 175 mL/min x cm2 (typical results @ 10 psi);687 mL/min x cm2/psi |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Color | White |
| Material | Nylon |
| Filter Type | Screen Filter |
| No. per Pack | 100Pack. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
MilliporeSigma™ Fluoropore™ Membrane Filters, 0.5 μm
Hydrophobic membrane with laminated backing for easier handling
| Pore Size | 0.45 μm |
|---|---|
| Bubble Point | 7 psi |
| Flow Rate | 60 mL/min x cm2 |
| Wettability | Hydrophobic |
| Type | Filter Membranes |
| Color | White |
| Material | PTFE |
| Hydrophobicity | Hydrophobic |
| For Use With (Application) | Clarification of Acids, Bases and Solvents; Clarification of Alcohol Solutions; UV Spectroscopy. |
| Autoclavable | Not Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 8.0 L/min/cm2 |
Cytiva Whatman™ 1.2μm Pore Size (ME 28) Mixed Cellulose Ester Membranes
Cytiva Whatman 1.2um Pore Size (ME 28) Mixed Cellulose Ester Membranes, Diameter Filter: 47mm, Pore Size: 0.2um
| Pore Size | 1.2 μm |
|---|
Cytiva Whatman™ 3 μm Pore Size (ME 29) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 29) Mixed Cellulose Ester Membranes, Plain are particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 3 μm |
|---|---|
| Flow Rate | 1.2 sec./100 mL/12.5 cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 29 |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 6.7 sec./100 mL (at Δp = 3 mbar) |
Cytiva Whatman™ 0.6 μm Pore Size (ME 26) Mixed Cellulose Ester Membranes, Plain
Whatman™ (ME 26) Mixed Cellulose Ester Membranes are particularly effective in applications requiring higher flow rates and larger volume filtration, including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring, and microbial analysis.
| Pore Size | 0.6 μm |
|---|---|
| Disposable | Single-use |
| Bubble Point | 3.7 bar |
| Flow Rate | 4.8 sec./100 mL/12.5cm² (at Δp = 0.9 bar) |
| Material (Membrane) | ME 26 |
| Grid Color | Plain |
| Material | MCE |
| Surface Type | Plain |
| For Use With (Application) | Filtration, cytology, air monitoring, aqueous HPLC samples, biological assays |
| Autoclavable | Autoclavable |
| Sterility | Non-sterile |
| Gas Flow Rate | 21 sec./100 mL (at Δp = 3 mbar) |