Slide Mounting Media
- (30)
- (1)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (2)
- (1)
- (23)
- (2)
- (1)
- (1)
- (3)
- (6)
- (1)
- (3)
- (1)
- (2)
- (8)
- (7)
- (1)
- (2)
- (1)
- (17)
- (7)
- (2)
- (1)
- (1)
- (1)
- (4)
- (2)
- (3)
- (3)
- (2)
- (12)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (21)
- (12)
- (1)
- (2)
- (23)
- (10)
- (2)
Filtered Search Results
Electron Microscopy Sciences Fluoro-Gel Mounting Medium with Tris Buffer 20 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Fluoro-Gel is a water based mounting medium designed for the permanent mounting of fluorescent stained tissues, which may either be damaged or soluble in organic solvents, such as xylene or toluene. This unique formula prevents rapid photo-bleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 488, Alexa Fluoro 594, Green Fluorescent Protein (GFP), Tetramethylyrhodamine, Redox, Phycoerythrin (RP-E), Phyocyanin (PC), and Allophycocyanin (APC).
The fluorescence is retained during prolonged storage at 4 degree C in the dark. Application: Immunofluorescence, confocal microscope.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Liquid Release Agent 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
A hydrosoluble mold-release agent for use in the flat embedding of micro-organisms, and as a replacement for the coating of glass slides to produce a smoother, even surface. The reference below describes the selection and precisely oriented sectioning of single cells by light microscopy, prior to examination by EM. Reymond, O.L. and Picket-Heaps, J.D., (1983) J. Microscopy, 130, 179.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EUKITT Neo Special Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
EUKITT Neo Special is a xylene free product and is characterized by faster curing and slightly higher viscosity than EUKITT Neo. Users of EUKITT Classic will appreciate the xylene free replacement. The product retains crystal-clear optics, low fluorescence, favorable refractive index, good fluidity and low shrinkage properties. The preparations are stable without cracking and discoloration.
EUKITT Neo Special is colorless and does not change shape, structure or color of the material to be examined. The use of sustainable, renewable raw material as a solvent completes the modern formulation approach.
The pleasant odor facilitates working in the laboratory. Supplied in wide neck, unbreakable aluminum bottles.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biolegend DAB 2 Component with Stabilizer
DAB 2 Component with Stabilizer Apps: IHC; Size: 1 kit
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF87, Glycerol Free, Non Hardening 25 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Immersion oil having a refractive index of 1.52 and contains an antifadent.
Material: Glycerol Free
Type: Non Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Ted Pella Inc CITIFLUOR GLYCEROL MEDIUM 25ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor, glycerol, PBS and additives,quantity:25ml,application:Immuno Fluorescent Mountant Media
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cayman Chemical AOCS MedIM nd LNgchaIn F 50mg
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
A mixture of medium- and long-chain fatty acid methyl esters; contains seven saturated and mono- and poly-unsaturated fatty acid methyl esters; intended for use as a reference standard for the detection of fatty acids in lard, beef tallow, mutton tallow, and palm oil, among others, by GC-MS; supplied in an amber ampule in which the headspace has been purged with nitrogen/argon to prevent lipid oxidation
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Fluoro-Gel III Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Fluoro-Gel is a water based mounting medium designed for the permanent mounting of fluorescent stained tissues, which may either be damaged or soluble in organic solvents, such as xylene or toluene. This unique formula prevents rapid photo-bleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 488, Alexa Fluoro 594, Green Fluorescent Protein (GFP), Tetramethylyrhodamine, Redox, Phycoerythrin (RP-E), Phyocyanin (PC), and Allophycocyanin (APC).
The fluorescence is retained during prolonged storage at 4 degree C in the dark. Application: Immunofluorescence, confocal microscope. Contains PI (Propidium Iodide) a counterstain for DNA.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
National Diagnostics OMNIMOUNT 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Omnimount, Universally compatible synthetic mounting medium. Ideally suited for use with HistoClear II, 100 ML
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Glycerol Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This aqueous mounting medium made with glycerol is for preserving fluorescence of tissue and cell smears. It is excellent for preserving thick sections that can not be mounted with mounting medium or fresh frozen tissues containing lipids, e.g. brain tissue.
This mounting medium is also useful for immunofluorescence. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy dyes, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine and Redox. The fluorescence is retained during prolonged storage at 4 degree C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes.
Not recommended for phycoethyrin (PE), phycocyanin (PC) and allophycocyanin (APC).
Reagent: Ready to use mounting medium for IHC and immunofluorescence (IF).
Refractive Index: 1.472. Storage at temperature of 2-8 degree C is recommended. Protect from light.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EUKITT UV Mounting Medium 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
EUKITT UV mounting medium has all the well-known beneficial properties of the EUKITT mountants. EUKITT UV does not contain any solvents, therefore only 50% of the usual amount is needed compared to conventional systems. While using EUKITT UV almost no shrinkage can be detected.
The mounting medium may be used on tissue sections in non-polar solvents such as xylene or xylene substitutes as well as directly on sections in pure alcohols (EtOH, iPrOH, etc.).
The viscosity is very user-friendly. After being applied to the tissue, the cover glass can be placed as usual. Subsequently, a transfer break of at least 120 sec. is maintained prior to irradiation in order to ensure an ideal penetration into the tissue.
When using the specially tuned LED CCFL UV curing machine EUKITT UV cures in just 30 seconds.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Technovit 3040 Mounting Medium Kit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Technovit 3040 yellow is a fast curing methyl methacrylate-based resin, whose chemical composition warrants a firm, durable bond between Technovit and the specimen.
Technovit 3040 consists of two components–powder and liquid–allowing simple mixing, easy adherance to the specimen, and fast curing. For fixing the mount, a high viscous consistency is required(i.e. a mixing ratio of approximately 2-3 parts per volume powder: 1 part per volume liquid) has proven to be the most advantageous.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
National Diagnostics HISTOMOUNT 450 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Histomount, Classic choice in synthetic mounting media, 450 ML
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences SEM Medium Resolution Au on Carbon Test Specimen, Hitachi Stub
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Larger gold particles in this test with wider gaps, allow for structured microscope setup. Magnification range is 800-10,000x.
Type: Hitachi Stub
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution PVP-1+Antifadent, Glycerol Free, Hardening 25 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Aqueous solution of poly(vinyl pyrrolidone) containing an amine-based antifadent.
Material: Glycerol Free
Type: Hardening
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More