Multiparameter Meters

Multiparameter Meters
- (2)
- (11)
- (4)
- (1)
- (3)
- (1)
- (5)
- (17)
- (14)
- (6)
- (1)
- (56)
- (30)
- (1)
- (5)
- (9)
- (1)
- (1)
- (1)
- (18)
- (1)
- (3)
- (11)
- (2)
- (23)
- (3)
- (8)
- (6)
- (38)
- (1)
- (4)
- (1)
- (14)
- (1)
- (8)
- (1)
- (6)
- (3)
- (2)
- (8)
- (3)
- (2)
- (1)
- (1)
- (9)
- (94)
- (9)
- (21)
- (1)
- (2)
- (3)
- (8)
- (10)
- (54)
- (3)
- (19)
- (8)
- (4)
- (8)
- (2)
- (10)
- (20)
- (11)
- (17)
- (32)
- (21)
- (39)
- (9)
- (12)
- (1)
- (35)
- (38)
- (41)
- (2)
- (66)
- (103)
- (1)
- (7)
- (16)
- (10)
- (2)
- (5)
- (1)
- (11)
- (10)
- (3)
- (63)
- (2)
Filtered Search Results

Fisherbrand™ accumet™ XL200 Benchtop pH/Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL200 pH/Conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.

Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | BNC, ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Warranty | 3 Years |
Temperature Accuracy | ±0.2°C |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Thermo Scientific™ Orion™ Pro Star PC215 pH/ion and Conductivity Bench Meter with Stand
Designed to provide accurate and reliable pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PC215 bench meter is well suited for laboratories that desire a modern meter with advance performance.

Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
---|---|
Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
Memory | Non-volatile |
Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Resolution (pH) | 0.1, 0.01 or 0.001 pH |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
Display Type | 7-in. High-resolution Color Graphic LCD |
Resolution (mV) | 0.1 mV |
Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
Data Points | 10,000 with Date and Time Stamp |
Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Warranty | 2 year meter warranty |
Temperature Accuracy | ±0.3°C, ±0.5°F |
Calibration Points (ISE) | Up to 5 |
Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Accuracy (TDS) | ±0.5% reading |
Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
Keypad | Capacitive touchscreen user interface |
Outputs | USB flash drive, computer or printer (STARA-106) |
Temperature Range (English) | -22.0°F to +266.0°F |
Range (Relative mV) | -2000 to 2000 mV |
Calibration Points (pH) | 1 to 5 points |
Backlight Option | Yes |
Range (mV) | -2000 to 2000 mV |
Range (ORP) | -2000 to 2000 mV |
Methods | 10 per channel (20 total) |
Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Channels | 2 |
Accuracy (pH) | ±0.002 pH |
Range (ISE) | 0.0001 to 19999 |
Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Accuracy (Salinity) | ±0.5% reading |
Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Accuracy (Conductivity) | ±0.5% reading |
Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC |
Weight (Metric) | 1.00 kg |
Resolution (ORP) | 0.1 mV |
Calibration Points (Conductivity) | 1 to 5 points |
Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
Isopotential Point | 7.000 pH; 1.000 ion concentration |
Accuracy (Resistivity) | ±0.5% reading |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Temperature |
Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
IP Rating | IP54 |
Weight (English) | 2.20 lbs. |
Range (Ion) | 0.0001 to 19999 |
Temperature Range (Metric) | -30.0°C to +130.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
Fisherbrand™ accumet™ AB200 Benchtop pH/Conductivity Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB200 pH/conductivity meter combines the benefits of a pH meter and conductivity meter in one easy to use, reliable measurement system. The large backlit display offers great visibility in laboratory environments.

Range (Resistivity) | 2 W to 20 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.010 to 10.000 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 500 |
Inputs | BNC, ATC |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Accuracy (mV) | ±0.2 mV |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.01/0.1μS, 0.001/0.01/0.1mS |
Range (Conductivity) | 0 μS to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0 ppm to 500 ppt (at TDS factor 1) |
Resolution (TDS) | 0/0.1ppm, 001/01/0.1ppt |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232 (phono plug), mini-B USB, stirrer |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Fisherbrand™ accumet™ XL500 Benchtop Dual pH/ISE and Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL500 dual pH/ISE/conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.

Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Thermo Scientific™ Orion Star™ A329 pH/ISE/Conductivity/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, ion concentration, conductivity, dissolved oxygen and temperature with our pH/ISE/conductivity/RDO/DO portable meter.
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 5000 with Date and Time Stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 5 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
Battery Type | 4 AA (included) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes (Selectable) |
Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6mmHg |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Pressure Resolution | 1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 3 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
Weight (Metric) | 0.5 kg |
Calibration Points (Conductivity) | Up to 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH |
Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP67 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
Model | Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
Weight (English) | 1.2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Height (English) | 3.89 in. |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.2°C (±0.3°F) |
Calibration Points (ISE) | 2 to 6 |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Resolution | Multiple |
Length (Metric) | 24.6 cm |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (DO) | 0.01mg/L (0.1mbar), 0.1% saturation |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (DO) | 0.1 +1 LSD |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Frequency | 50/60Hz |
Weight (English) | 2.5 lb. |
Range (DO) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
Temperature Resolution | 0.1°C |
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
---|---|
Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
Range (Resistivity) | 1.0Ω to 100.0 MΩ |
Memory | Non-volatile |
Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Resolution (pH) | 0.1, 0.01 or 0.001 pH |
Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
Display Type | 7-in. High-resolution Color Graphic LCD |
Resolution (mV) | 0.1 mV |
Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
Data Points | 10,000 with Date and Time Stamp |
Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Probe Type | Polarographic or optical DO electrode |
Salinity Factor | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Warranty | 2 year meter warranty |
Temperature Accuracy | ±0.3°C, ±0.5°F |
Calibration Points (ISE) | Up to 5 |
Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
Accuracy (TDS) | ±0.5% reading |
Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
Keypad | Capacitive touchscreen user interface |
Outputs | USB flash drive, computer or printer (STARA-106) |
Temperature Range (English) | -22.0°F to +266.0°F |
Range (Relative mV) | -2000 to 2000 mV |
Calibration Points (pH) | 1 to 5 points |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Range (mV) | -2000 to 2000 mV |
Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
Range (ORP) | -2000 to 2000 mV |
Methods | 10 per channel (30 total) |
Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
Channels | 3 |
Accuracy (pH) | ±0.002 pH |
Range (ISE) | 0.0001 to 19999 |
Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
Accuracy (Salinity) | ±0.5% reading |
Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | ±0.5% reading |
Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
Weight (Metric) | 1.00 kg |
Resolution (ORP) | 0.1 mV |
Calibration Points (Conductivity) | 1 to 5 points |
Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
Resolution (Resistivity) | 0.1 Ωminimum, auto-ranging |
Isopotential Point | 7.000 pH; 1.000 ion concentration |
Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
Accuracy (Resistivity) | ±0.5% reading |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
IP Rating | IP54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.20 lbs. |
Range (Ion) | 0.0001 to 19999 |
Temperature Range (Metric) | -30.0°C to +130.0°C |
Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with Date and Time Stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 6 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Relative Humidity Range | 5 to 85%, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6 mmHg |
Range (ORP) | ±2000.0 mV |
Pressure Resolution | 0.1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 (Customizable with modules) |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Fisherbrand™ accumet™ XL250 Benchtop pH/ISE Dual Channel Meters
Provide advanced pH and ion measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL250 pH/ISE dual channel benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Length (Metric) | 24.6 cm |
---|---|
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Voltage | 100/240 V |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter
Accurate measurements any time, anywhere
Accuracy (mV) | 0 to ±2000mV |
---|---|
Warranty | 3 Years |
Resolution (pH) | Adjustable |
Measurement Modes | pH,Ion,mV,Temperature |
Range (pH) | 2 to 20 |
Range | -2 to +20pH |
For Use With (Application) | pH, Ion concentration, mV, Temperature |
Includes | Meter, 9V battery, manual |
Calibration Points | 10 |
Accuracy | Multiple |
Display Type | LCD |
Product Type | Meter Only |
IP Rating | IP67 |
Temperature Range (English) | 23°F to 212°F |
Data Points | 200 |
Temperature Range (Metric) | -5°C to +100°C |
Range (mV) | 0 to ±2000 mV |
Resolution | Multiple |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with Date and Time Stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 year meter and module warranty |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Range (mV) | ±2000.0 mV |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Range (pH) | -2 to 20 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 (Customizable with modules) |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable) |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
Mettler Toledo™ S975 SevenExcellence™ pH/Conductivity/Ion/DO Meter Kit
Professional modular triple-channel instrument for measuring ion concentrations, pH, mV/ORP, rel. mV, conductivity, salinity, TDS, resistivity and conductivity ash
METTLER TOLEDO™ Portable pH/Conductivity/Dissolved Oxygen/Ion Meters
Water and dust proof, IP67 rated meter for portable or field measurements. Portable meters compatible with pH, conductivity, dissolved oxygen, and ion selective electrodes.
IP Rating | IP67 |
---|---|
Certifications/Compliance | ISO 9001:2000 |
Fisherbrand™ Traceable™ pH/ORP/Temperature Meter
Measure critical water quality parameters — without the need to carry multiple units.

Fisherbrand™ accumet™ AP125 Portable pH/Ion/mV/Temperature Meter Kit
Accurate measurements any time, anywhere