Invitrogen™ Hoechst 33342 Ready Flow™ Reagent
Description
This dye emits blue fluorescence when bound to double-stranded DNA with an emission maximum at 461 nm.
• Stable at room temperature
• Convenient, ready-to-use format—no need to dilute, weigh, or pipette
• Cell-permeable and effective in fixed and live-cell staining for cell cycle
Hoechst 33342 Ready Flow Reagent is a cell-permeable, blue fluorescent DNA stain for cell cycle analysis. Add 2 drops from the dropper bottle directly into 1 x 106 cells, incubate, and analyze.
Hoechst 33342 reagent binds preferentially to adenine-thymine regions of double-stranded DNA. This dye binds into the minor grooves of DNA and exhibits distinct fluorescence emission spectra that are dependent on dye:base pair ratios. Hoechst 33342 Ready Flow Reagent is excited by UV light and has peak emission at 460 nm.
Specifications
Specifications
| Color | Blue |
| Content And Storage | 2 dropper bottles, store at room temperature |
| Excitation Wavelength Range | 361/497 |
| Dye Type | Cell-Permeant |
| Quantity | 120 assays |
| Product Line | Ready Flow |
| Product Type | Nucleic Acid Stain |
| Sub Cellular Localization | Nucleus |
Frequently Asked Questions (FAQs)
DAPI is considered a semi-permeant/impermeant nucleic acid stain. Staining of nucleic is dependent upon the cell line in its performance. Some cell lines will label with DAPI, others not at all, and others label inconsistenly. Instead, we recommend using either Hoechst 33342 or Hoechst 33258, which have the same wavelength and binding mode as DAPI (at the A-T minor groove) but are readily cell-permeant.
We do not recommend doing this. DAPI is considered to be a semi-permeant/impermeant nucleic acid stain. DAPI staining of live cells may be inconsistent. It is best used as a counterstain for fixed samples. Other cell permeable nucleic acid stains, such as Hoechst or the SYTO dyes may affect cellular function.
For mammalian cells, we recommend using the CellLight Nucleus transduction reagents, available in CFP, GFP and RFP. With these reagents, the cells are transduced overnight in a single labeling step and the next day the nuclei will fluoresce. The label may be retained for 3-5 days and should not affect cell function. Cytoplasmic cell tracking dyes such as the CellTracker dyes may also be used.
Yes, you may scale up or down as needed, but we recommend keeping the cell density the same. There are 41 µL per drop, so 2 drops is 82 µL (for the 1 mL of sample). You need to only scale down for this 100 µL volume, which would be 8.2 µL.
The amount of dye or reagent in the Ready Flow products is proprietary. If you need to consider the exact amount of dye or reagent for your experiment, each of the Ready Flow reagents is available as a standalone product.
This is not recommended. The ReadyProbes reagents were developed for imaging applications whereas the Ready Flow reagents were optimized for flow cytometry.
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.