HPLC Columns and Cartridges
Filtered Search Results
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 18% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ Surfactant HPLC Columns
Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 12% |
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Organic Acid HPLC Columns
Use for separation of hydrophilic, aliphatic, and aromatic organic acids.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 17% |
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 2 to 8 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ 120 C8 HPLC Columns
Achieve exceptional performance and maximum resolution for reversed-phase separation of analytes with moderate hydrophobicity.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C8 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L7 |
Thermo Scientific™ Acclaim™ Carbamate HPLC Columns
Achieve baseline separation of carbamate specified in U.S. EPA Method 531.2 with high-efficiency Thermo Scientific™ Acclaim™ Carbamate LC Columns.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Proprietary |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Specialty/Application Specific |
| pH | 3 to 7 |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ C30 HPLC Columns
Use for superior separation of hydrophobic structural isomers.
| Pore Size | 200 Å |
|---|---|
| Carbon Load | 13% |
| Stationary Phase | C30 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 200 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
| Temperature | 50°C |
| Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
| Endcapped | Proprietary |
| Column Type | Mixed Mode |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L85 |
Thermo Scientific™ Acclaim™ Polar Advantage HPLC Columns
Use for reversed-phase separation of basic or pharmaceutical compounds using highly aqueous mobile phases.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 17% |
| Stationary Phase | Polar Embedded |
| Temperature | 60°C |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L60 |
Thermo Scientific™ Acclaim™ Surfactant Plus HPLC Columns
Use for simultaneous separation of anionic, nonionic, cationic, and amphoteric surfactants with CAD and LC-MS detection.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Proprietary |
| Temperature | 50°C |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Specialty/Application Specific |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
Thermo Scientific™ Acclaim™ Mixed Mode WAX-1 HPLC Columns
When you need powerful selectivity control for the separation of anionic molecules, use Thermo Scientific™ Acclaim™ Mixed-Mode WAX-1 LC columns.
| Pore Size | 120 Å |
|---|---|
| Phase | Reversed Phase, Ion Exchange, HILIC |
| Column Type | Mixed Mode |
| pH | 2.5 to 7.5 |
| Green Features | Responsibly packaged |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L78 |
Thermo Scientific™ Acclaim™ Polar Advantage II HPLC Columns
Resolve polar and nonpolar compounds in a single run. These columns have high pH stability (pH 1.5–10) in the separation of basic, neutral, and acidic species.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Polar Embedded |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Column Type | Reversed Phase |
| Surface Area | 300 m²/g |
| USP Type | L60 |
Thermo Scientific™ Acclaim™ Trinity Q1 LC Columns
Use to separate the herbicides diquat and paraquat.
Thermo Scientific™ Acclaim™ AmG C18 HPLC Columns
Meet today’s demands for aminoglycoside antibiotic analyses, including drug purity characterization & quantification. They have unique tolerance to harsh conditions.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 3 μm |
| Stationary Phase | C18 |
| Temperature | <80°C |
| Phase | Reversed Phase |
| Packing Material | Spherical, High Purity Silica |
| Column Type | Aminoglycoside Analysis |
| pH | 0.5 to 10 |
| Green Features | Responsibly packaged |
| Max. Pressure | 8000 psi (550 bar) |
| Product Line | Acclaim |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 8% |
| Stationary Phase | Proprietary |
| Temperature | 70°C |
| Phase | HILIC |
| For Use With | LC/MS |
| Endcapped | Yes |
| Column Type | HILIC |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |