pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
Mettler Toledo™ FiveEasy™ F20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | Current calibration |
| Resolution (pH) | 0.01 |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | F20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
Thermo Scientific™ Orion™ Sure-Flow™ Single Junction Epoxy Bodied Reference Electrode
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Attain stable, drift-free reference measurements using a sure-flow electrode with its unique free-flowing liquid-to-liquid junction.
Thermo Scientific™ Orion Star™ A222 Conductivity Portable Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity portable meter for advanced field analysis.
| Salinity Measurement Modes | Practical salinity (psu) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 megohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
| Battery Life | 800 hr. |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 1000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Battery Type | 4 x AA (included) |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 15, 20, 25°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | Conductivity and temperature |
| Alarm Output | Calibration due alarm (fixed 12 hour) |
| IP Rating | IP67 |
| Model | Orion Star A222 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5°C to +105°C |
Mettler Toledo™ Replacement Parts for V20 Karl Fischer™ Autotitrator
For use with V20 Karl Fischer Autotitrators.
Mettler Toledo™ Economy Series pH and pH/ATC Combination Electrodes
Offer outstanding price/performance ratio. Mettler Toledo Economy Series pH and pH/ATC Combination Electrodes are cost-effective alternative for less-demanding requirements.
| Temperature (Metric) Range | 0°C to 100°C |
|---|---|
| Temperature (English) Operating | 0°F to 176°F |
| For Use With (Equipment) | pH meter |
| Length (English) Cable | 47 in. |
| Temperature (Metric) Operating | 0°C to 80°C |
| Connector Types | BNC |
Thermo Scientific™ Orion™ ROSS Ultra™ Thin Stem Glass Bodied Combination pH Electrode
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Top-performance, semi-micro pH electrodes to measure samples as small as 0.2 mL
METTLER TOLEDO™ InLab™ Expert pH Electrodes
A combination pH electrode with PEEK plastic shaft for chemical and mechanical durability, and a fixed cable. Designed for use in a variety of applications.
| Diameter (English) | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Membrane | U Glass |
| Filling Solution Type | Xerolyt Polymer |
| Material | PEEK |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ARGENTHAL |
OHAUS™ Starter pH Pen Meters
Convenient pH testing. OHAUS Starter pH Pen Meters offer a convenient way to measure pH, or the relative acidity or alkalinity of a sample at a given temperature. The pH pen meters can be completely operated with just one hand, freeing up your other hand to handle samples.
| Calibration Points | 3 |
|---|---|
| Includes | 4 1.5V Batteries |
| Type | Portable pH Meter |
| Log Function Type | Automatic Data Logging |
| Data Points | 30 |
| Backlight Option | None |
| Weight (English) | 0.24 lb. |
| Range (pH) | 0 to 14 |
| Calibration | Automatic/Manual |
| For Use With (Application) | Measuring pH, or the relative acidity or alkalinity of a sample at a given temperature |
| Battery Type | 4 x AG13 1.5 V Micro Alkaline |
| Accuracy (pH) | ±0.1 |
| Weight (Metric) | 110 g |
Thermo Scientific™ Orion™ Dissolved Oxygen/BOD Probe
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Make any pH meter a dissolved oxygen meter with this dissolved oxygen/BOD probe.
| Dissolved Oxygen (Concentration Range) | 0 to 14 ppm |
|---|---|
| For Use With (Equipment) | Dissolved Oxygen/BOD Probe |
| Sensor Types | Polarographic Dissolved Oxygen Sensor |
| Temperature (Metric) Operating | 15°C to 35°C |
Thermo Scientific™ Orion™ Single Junction Refillable Epoxy Bodied pH/ATC Triode™
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Accurately measure pH and temperature together in just one electrode, with a built-in temperature sensor.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 194°F |
| For Use With (Equipment) | Orion pH Meter (field or plant-use) |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Length (English) | 4.7 in. |
| Material | Epoxy |
| Junction | Glass Fiber |
| Diameter (Metric) Body | 12 mm |
| For Use With (Application) | ideal for field or plant use. |
| Temperature (Metric) Operating | 0°C to 90°C |
| Internal Reference | Ag/AgCl |
Thermo Scientific™ Orion™ Pro Star PI217 Dual Channel pH/Ion Bench Meter
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Designed to provide accurate and reliable pH, ORP, ion concentration and temperature analysis, the Thermo Scientific™ Orion™ Pro Star PI217 dual channel bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Temperature (Metric) Range | -30.0°C to +130.0°C |
|---|---|
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Resolution (pH) | 0.1, 0.01 or 0.001 pH |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP with mV and Temperature,Ion Concentration (ISE) with Temperature |
| Range (pH) | -2 to 20 |
| Resolution (ISE) | 0.0001 minimum, 1 to 5 digits |
| Channels | 2 |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Data Points | 10,000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference |
| Accuracy (Temperature) | ±0.3°C, ±0.5°F |
| Weight (Metric) | 1.00 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Calibration Points (ISE) | Up to 5 |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Calibration | pH, ORP, Ion Concentration, Temperature |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | PI217 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Range (mV) | -2000 to 2000 mV |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (20 total) |
Thermo Scientific™ Orion™ Combination pH Electrodes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Environmentally friendly lab pH electrodes to meet RoHS requirements by containing no lead, mercury or other hazardous substances — making disposal of old electrodes easy and hassle free.
| Length (Metric) Cable | 1 m |
|---|---|
| For Use With (Equipment) | Orion pH Meter |
| pH Range | 0 to 14 |
| Length (English) Cable | 39.3 in. |
| Material | Epoxy Body |
| Temperature (Metric) Operating | 0°C to 90°C |
Thermo Scientific™ Orion™ Chloride Ion Selective Electrodes
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Easily and reliably analyze free chloride ions in aqueous solutions. Provides quick, accurate and economical measurements.
| Type | Combination ISE |
|---|---|
| For Use With (Equipment) | Chloride electrodes can be used on any ISE meter with a BNC connection The electrodes can also be used on meters with a variety of inputs when an adapter cable is used. |
Thermo Scientific™ Orion™ Swing Arm Electrode Stand
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quickly move electrodes between samples with the Thermo Scientific™ Orion™ Swing Arm Electrode Stand, featuring 360 degrees of motion and cable management system
Oakton™ pH and pH/Conductivity Electrode Replacements, pH/Temp Combination Electrode; Single-Junction, Epoxy
Replace Oakton™ pH and pH/Conductivity Electrodes when they break, no longer hold calibration, cannot be rehydrated, or are not compatible with your sample.
| Includes | Electrode |
|---|---|
| Warranty | 1 Year |
| Temperature (English) Operating | 32°F to 176°F |
| Membrane | None |
| Drift | Unknown |
| Material | Epoxy |
| Junction | Single |
| Storage Requirements | Oakton electrode storage solution or a 2 to 4mol/L KCl solution |
| Temperature (Metric) Operating | 0°C to 80°C |