pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.






Filtered Search Results

Fisherbrand™ accumet™ Gel-Filled Paper Pulp Double-Junction pH Combination Electrodes: Mercury-Free
Dual junctions provide fast response and long life in paper pulp testing
Type | Combination pH Electrode |
---|---|
For Use With (Equipment) | pH meter |
pH Range | 0 to 14 |
Response Time | 30 sec. |
Filling Solution Type | Gel |
Material | Gel-filled Polymer/Polypropylene |
Junction | Dual |
pH Relative Accuracy | ±0.05 |
For Use With (Application) | Ideal for routine process monitoring in paper pulp plants, mine assay labs, smelters |
Fisherbrand™ accumet™ Solid-State Half-Cell ISEs, Mercury-Free: Fluoride, BNC Connector
For fluoride determinations. BNC connector.
Fisherbrand™ accumet™ Epoxy Body pH/ATC Probe for Corning Meters - Mercury-Free
With BNC connector and ATC connector for Corning Meters
Fisherbrand™ accumet™ Universal pH/ATC Electrodes
Combination pH mercury-free electrodes with built-in temperature compensation
Includes | Cable with BNC and ATC connectors, electrode storage bottle |
---|---|
Filling Solution Type | Gel |
Material | Epoxy |
Junction | Double |
Fisherbrand™ accumet™ Gel-Filled Polymer Body Single-Junction pH Combination Electrodes, Mercury-Free
Rugged polymer construction for handheld use with aqueous samples in the classroom or in the field
Type | Combination pH Electrode |
---|---|
Warranty | 1 Year |
Length (Metric) | 146 mm |
pH Range | 0 to 14 |
Response Time | <10 sec. |
Length (English) | 5.75 in. |
Filling Solution Type | 4mol/L KCl gel |
Material | Polymer/Polypropylene |
Junction | Single Ceramic |
For Use With (Application) | Ideal for handheld use with aqueous samples |
Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ Temperature-Compensated Two-Cell Conductivity Probes, Mercury-Free
For use on accumet™ Excel (XL) series benchtop meters.
Type | Conductivity Probe |
---|---|
For Use With (Equipment) | AB200, XL20, XL200, XL30, XL50, XL500, XL60, XL600 Benchtop Meters |
Material | Epoxy |
Probe | 2 Cell Conductivity |
Storage Method | Immersed in deionized water |
Connector Types | 8-pin |
Fisherbrand™ accupHast™ Variable Temperature pH Combination Electrodes: Mercury-Free
Fast, accurate response despite temperature changes
Diameter (English) | 0.4 in. |
---|---|
pH Range | 0 to 14 |
Diameter (Metric) | 10 mm |
Filling Solution Type | Saturated KCl |
Junction | Dual Ceramic |
Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ Replacement Conductivity/TDS/Temperature Probe - Mercury - Free
Replacement probe to be used for conductivity, TDS, and temp.
Fisherbrand™ accumet™ Glass Body Ag/AgCl Reference Electrodes - Mercury-Free
Recommended for stability at higher temperatures and for use with strongly basic samples
Type | Ag/AgCl Reference Electrode |
---|---|
Temperature (Metric) Range | 0°C to 100°C |
Length (Metric) | 106 mm |
Temperature (English) Operating | 32°F to 212°F |
pH Range | 0 to 14 |
Filling Solution Type | 4mol/L KCl with AgCl |
Material | Glass |
Diameter (Metric) Body | 12 mm |
For Use With (Application) | Recommended for stability at higher temperatures and for use with strongly basic samples |
Temperature (Metric) Operating | 0°C to 100°C |
Connector Types | Pin |
Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ XL500 Benchtop Dual pH/ISE and Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL500 dual pH/ISE/conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Fisherbrand™ accumet™ XL600 Benchtop Dual pH/ISE, Conductivity and Dissolved Oxygen Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display. Fisherbrand accumet XL600 pH/ISE/conductivity/DO benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Height (English) | 3.89 in. |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.2°C (±0.3°F) |
Calibration Points (ISE) | 2 to 6 |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Resolution | Multiple |
Length (Metric) | 24.6 cm |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% FS |
Resolution (DO) | 0.01mg/L (0.1mbar), 0.1% saturation |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (DO) | 0.1 +1 LSD |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Frequency | 50/60Hz |
Weight (English) | 2.5 lb. |
Range (DO) | 0 to 20mg/L (0 to 1272mbar), 0 to 200% saturation with 13-620-SSP electrode |
Temperature Resolution | 0.1°C |
Fisherbrand™ accuCap™ Capillary Junction pH Combination Electrodes - Plastic Body, Gel-Filled - Mercury-Free
Large junction for increased flow, minimal clogging
Fisherbrand™ accumet™ Liquid-Filled Polymer Body Combination Electrodes: Mercury-Free
Ideal for measurements in small vessels or with small samples
Diameter (English) | 0.4 in. |
---|---|
Type | Combination pH Electrode |
Temperature (Metric) Range | -5°C to +100°C |
Length (Metric) | 106 mm |
Temperature (English) Operating | 23°F to 212°F |
pH Range | 0 to 14 |
Diameter (Metric) | 10 mm |
Length (English) | 4.1 in. |
Material | Polypropylene |
For Use With (Application) | For measurements in small vessels or with small samples |
Temperature (Metric) Operating | -5°C to +100°C |
Internal Reference | Ag/AgCl |
Fisherbrand™ accupHast™ R Rugged Variable Temperature pH Combination Electrodes - Mercury-Free
Fast response despite temperature changes plus extra durability
Diameter (English) | 0.4 in. |
---|---|
Temperature (Metric) Range | -5°C to +100°C |
Length (Metric) | 102 mm |
Temperature (English) Operating | 23°F to 212°F |
pH Range | 0 to 14 |
Length (English) | 4 in. |
For Use With (Application) | Biological, pharmaceutical and Tris |
Type | Combination pH Electrode |
For Use With (Equipment) | pH meter |
Diameter (Metric) | 10 mm |
Filling Solution Type | SP138-500 |
Temperature (Metric) Operating | -5°C to +100°C |
Connector Types | BNC |
Internal Reference | Ag/AgCl |
Fisherbrand™ accumet™ Micro and Semimicro Size Glass Combination Electrodes - Mercury - Free
Ideal for microwell plates, serum cups, cuvets, micro test tubes, NMR tubes and capillary tubes
Warranty | 1 Year |
---|---|
Temperature (Metric) Range | -5°C to +110°C |
Tip Type | Micro |
Temperature (English) Operating | 23°F to 230°F |
pH Range | 0 to 14 |
Filling Solution Type | Saturated KCl with AgCl. KCl |
Material | Glass |
Junction | Single |
For Use With (Application) | Small samples |
Temperature (Metric) Operating | -5°C to +110°C |
Internal Reference | Ag/AgCl |