ELISA is an analytical method based on the highly specific interaction between an antigen and an antibody. For this assay, an antigen is attached to a solid surface, to which an antibody-enzyme complex is linked. When a substrate is added and incubated with the other materials, it produces a measurable product.
Filtered Search Results
R&D Systems™ Human Proadrenomedullin/Pro-ADM ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Human Proadrenomedullin/Pro-ADM ELISA Kit (Colorimetric) measures Human Proadrenomedullin/Pro-ADM in Serum, plasma, cell supernatant, and other biological fluids.
Invitrogen™ Mouse MCP-1 ProQuantum Immunoassay Kit
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Immunoassay Kit Format | Proximity-based Immunoassay |
|---|---|
| Target Species | Mouse |
| Conjugate | FAM |
| Incubation Time | 1 hr. |
| Total Assay Time | 2 hr |
| Sample Volume | Plasma 2-5 μL, Serum 2-5 μL, Supernatant 2-5 μL |
| Assay Sensitivity | 0.06 pg/mL |
| Storage Requirements | -20°C |
| Assay Range | 0.064-5000 pg/mL |
| For Use With (Application) | Protein Quantitation |
| Test Time | 30 min |
| Detection Method | Taqman™ Real-time PCR |
| Accession Number | P10148 |
| Regulatory Status | RUO |
| Target | CCL2 (MCP-1) |
| Kit Contents | Assay Dilution Buffer, Antibody-Conjugate A, Antibody-Conjugate B, Antibody-Conjugate Dilution Buffer, Standard, Master Mix, Ligase,Antibody-Conjugate A,Antibody-Conjugate B,Antibody-Conjugate Dilution Buffer,Standard,Master Mix,Ligase |
| For Use With (Equipment) | qPCR Instruments |
| Product Type | ProQuantum |
| Gene ID (Entrez) | 20296 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | FAM™ |
Invitrogen™ Human ULBP-1 ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Conjugate | HRP |
|---|---|
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | ULBP1 |
| Total Assay Time | 4 hr 45 min |
| Sample Volume | Plasma 50 μL, Serum 50 μL, Supernatant 50 μL |
| Assay Sensitivity | 0.4 ng/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 0.4-100 ng/mL |
| Test Time | 1 hr 20 min |
| Accession Number | Q9BZM6 |
| Regulatory Status | RUO |
| Target | ULBP1 |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 80329 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | Biotin |
R&D Systems™ Human Complement Component C9 ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Kit (Colorimetric)
Invitrogen™ Human MIP-3 alpha/CCL20 ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Shipping Condition | Wet or Dry Ice |
|---|---|
| Protein Family | Chemokines & Receptors |
| Immunoassay Kit Format | Sandwich ELISA Kit |
| Target Species | Human |
| Conjugate | HRP |
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | CCL20 |
| Total Assay Time | 4 hr 45 min |
| Assay Sensitivity | 1.5 pg/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 1.5-600 pg/mL |
| Test Time | 1 hr 20 min |
| Accession Number | P78556 |
| Regulatory Status | RUO |
| Target | CCL20 |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| Gene Alias | beta chemokine exodus-1; beta-chemokine exodus-1; CC chemokine LARC; CC chemokine ST38; C-C motif chemokine 20; C-C motif chemokine ligand 20; Ccl20; CCL20(1-64); CCL20(1-67); CCL20(2-70); chemokine (C-C motif) ligand 20; CKb4; Exodus; exodus-1; LARC; Liver and activation-regulated chemokine; macrophage inflammatory protein 3 alpha; MIP 3 a; MIP 3 α; MIP 3alpha; MIP 3α; MIP3 a; MIP3 alpha; MIP3 α; MIP-3[a]; MIP3A; MIP-3A; MIP-3-alpha; M-MIP-3-alpha; SCYA20; small inducible cytokine subfamily A (Cys-Cys), member 20; small inducible cytokine subfamily A20; small-inducible cytokine A20; St38beta chemokine exodus-1; beta-chemokine exodus-1; CC chemokine LARC; CC chemokine ST38; C-C motif chemokine 20; C-C motif chemokine ligand 20; Ccl20; CCL20(1-64); CCL20(1-67); CCL20(2-70); chemokine (C-C motif) ligand 20; CKb4; Exodus; exodus-1; LARC; Liver and activation-regulated chemokine; macrophage inflammatory protein 3 alpha; MIP 3 a; MIP 3 α; MIP 3alpha; MIP 3α; MIP3 a; MIP3 alpha; MIP3 α; MIP-3[a]; MIP3A; MIP-3A; MIP-3-alpha; M-MIP-3-alpha; SCYA20; small inducible cytokine subfamily A (Cys-Cys), member 20; small inducible cytokine subfamily A20; small-inducible cytokine A20; St38; CKb4; Exodus; LARC; MIP-3-alpha; MIP-3a; MIP3A; SCYA20; ST38 |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 6364 |
| Sample Type | Cell Lysates,Plasma,Serum,Supernatant,Tissue Homogenates |
| Label or Dye | Biotin |
R&D Systems™ Human LMAN2 ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Colorimetric ELISA Kit
R&D Systems™ Porcine Apolipoprotein E/ApoE ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Colorimetric ELISA Kit
R&D Systems™ Mouse Cerberus 1 ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Colorimetric ELISA Kit
R&D Systems™ Rat Adiponectin/Acrp30 DuoSet ELISA
Rat Adiponectin/Acrp30 DuoSet ELISA from the most referenced ELISA manufacturer. Highly validated for accurate quantitation and long-term reproducibility.
Invitrogen™ Human Syndecan-3 ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Conjugate | HRP |
|---|---|
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | Sdc3 |
| Total Assay Time | 4 hr 45 min |
| Sample Volume | Plasma 50 μL, Serum 50 μL, Supernatant 50 μL |
| Assay Sensitivity | 0.61 ng/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 0.061-15 ng/mL |
| Test Time | 1 hr 20 min |
| Accession Number | O75056 |
| Regulatory Status | RUO |
| Target | Syndecan 3 |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 9672 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | Biotin |
Invitrogen™ Mouse Leptin R ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Conjugate | HRP |
|---|---|
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | Lepr |
| Total Assay Time | 4 hr 45 min |
| Sample Volume | Plasma 50 μL, Serum 50 μL, Supernatant 50 μL |
| Assay Sensitivity | 32 pg/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 32-8000 pg/mL |
| Test Time | 1 hr 20 min |
| Accession Number | P48356 |
| Regulatory Status | RUO |
| Target | Leptin Receptor |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 16847 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | Biotin |
Invitrogen™ Human Trypsin 2/PRSS2 ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Conjugate | HRP |
|---|---|
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | PRSS2 |
| Total Assay Time | 4 hr 45 min |
| Sample Volume | Plasma 50 μL, Serum 50 μL, Supernatant 50 μL |
| Assay Sensitivity | 25 pg/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 25-6000 pg/mL |
| Test Time | 1 hr 20 min |
| Accession Number | P07478 |
| Regulatory Status | RUO |
| Target | Trypsin 2 |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 5645 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | Biotin |
Invitrogen™ Human GDF-9 ELISA Kit
ELISA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Conjugate | HRP |
|---|---|
| Interassay CV | <12% |
| Intraassay CV | <10% |
| Gene Symbol | GDF9 |
| Total Assay Time | 4 hr 45 min |
| Sample Volume | Plasma 50 μL, Serum 50 μL, Supernatant 50 μL |
| Assay Sensitivity | 2.2 ng/mL |
| Storage Requirements | Maintain refrigerated at 2-8°C for up to 6 months. For long term storage store at -20°C |
| Assay Range | 2.2-500 ng/mL |
| Test Time | 1 hr 20 min |
| Accession Number | O60383 |
| Regulatory Status | RUO |
| Target | GDF9 |
| Kit Contents | Pre-coated 96 well plate, Standard, Assay Diluent concentrate, Biotinylated Detection Antibody, SAV-HRP, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers,Standard,Assay Diluent concentrate,Biotinylated Detection Antibody,SAV-HRP,Wash Buffer,Chromogen,Stop Solution,Adhesive Plate Covers |
| For Use With (Equipment) | Absorbance Microplate Reader |
| Product Type | ELISA |
| Gene ID (Entrez) | 2661 |
| Sample Type | Plasma,Serum,Supernatant |
| Label or Dye | Biotin |
R&D Systems™ Human BNP ELISA Kit (Colorimetric)
A Novus product, part of R&D Systems. Assay has high sensitivity and specificity for detection of human BNP
Thermo Scientific™ CaptureSelect™ AVB Sepharose HP Leakage ELISA
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Thermo Scientific™ CaptureSelect™ AVB Sepharose HP Leakage ELISA is designed to detect possible leached ligand of adeno-associated viruses (AAV) purified using AVB Sepharose HP affinity resin (Cytiva).
| Assay | ELISA |
|---|---|
| Target | AVB Sepharose HP Affinity Ligand |
| Content And Storage | Store at -20°C. |
| Format | Individual components |
| Product Type | Ligand Leakage ELISA |
| For Use With (Equipment) | Microplate Reader |
| Product Line | CaptureSelect |