Animal Surgical Equipment Accessories
- (2)
- (7)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (4)
- (1)
- (3)
- (1)
- (1)
- (4)
- (4)
- (1)
- (1)
- (4)
- (3)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (2)
- (1)
- (2)
- (1)
- (1)
- (3)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (8)
- (2)
- (1)
- (1)
- (6)
- (9)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (6)
- (3)
- (1)
- (1)
- (1)
- (9)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (2)
- (3)
- (8)
Filtered Search Results
Vetequip Inc PRIMARY CHARCOAL FILTER FOR MO
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Filter, Primary Activated Carb -all AIR Sys Filt
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
World Precision Instrument Ear Tag Applier
Place the ear tag in the applicator keeping the hole side of the tag flat against the jaw of the applicator with the indentation. Locate the tag within the ear, applying beyond a ring of cartilage. After sealing, be sure to check that the tag point has come through the hole and bent around sealing properly. Tags should be washed in alcohol or similar cleaning solution to help prevent infection to the ear.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
SAI Infusion Technologies Rat Femoral Artery Catheter - 125g+, 7.8cm tip
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This item has a minimum qty of 3 per supplier requirements.
Femoral artery catheter for rat > 125g. 7.8cm 2Fr PU tip, PE body, accepts 22G blunt needle, 4 suture beads to anchor the catheter in place. Product is for laboratory animal research only. ** If a COA is required it must be requested when the order is placed or a $50.00 fee will be apply. Contact Thermo Fisher Customer Service at 800-766-7000 to request to COA. **
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Med Vet International Endotracheal Tubes, Cuffed, 5.5 mm, 10/Box
Endotracheal Tubes, Cuffed, 5.5 mm, 10/Box
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech Harvard Apparatus Pump 11 Elite inf/wd programmable single syringe pump (704504), US cord
The HA1100W is a programmable single-syringe infuse/withdraw pump from the Harvard Apparatus 11 Elite series. It features a high-resolution touch screen for creating complex methods without a PC. The advanced mechanism ensures accurate, pulse-free flow for applications ranging from microdialysis to large volume infusions.
Features
- Type: Single-syringe infuse/withdraw programmable pump
- Syringe Size: 0.5µl to 60ml
- Flow Rates: 1.28 pl/min to 88.28 ml/min
- Interface: 4.3 inch color touchscreen
- Memory: Stores 2 user-defined methods (50 steps each)
- Accuracy: ±0.5% with ±0.05% reproducibility
- Connectivity: USB, RS-485, and 15-pin digital I/O
- Linear Force: 35 lbs (16 kg)
- Occlusion Alarm: None
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Single axis counter-balanced lever arm to hold Instech stainless steel swivels. For tethered infusion of rats.
The Instech CM375BS is a single‑axis counter‑balanced lever arm designed for stainless steel swivels in rat shoebox cages. Its vertical‑pivot design removes slack from the tether while allowing the animal to reach all cage corners, and its adjustable counterweight balances the swivel and tether for smooth, stress‑reducing movement.
Features
- Single‑axis vertical pivot for controlled tether travel
- Counter‑balanced design for stainless steel swivels
- Prevents tangling and reduces animal restraint
- Supports full cage‑corner reach in asymmetrical cages
- Compatible with standard rodent shoebox cage tops
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech PHD Ultra push/pull programmable syringe pump (703009), US cord
Syringe pump, Harvard Apparatus PHD Ultra, programmable push/pull, dual syringe rack. US power cord. Touch screen interface. Purchase multi rack kits separately: HA3020A (6/10), HA3021A (4X140), HA3022A (microliter).
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech Covance Infusion Harness™ for mice, harness only, non-sterile. For tethered infusion or sampling with mice.
The Instech CIH62AB is a Covance Infusion Harness for mice designed to protect externalized catheters and provide stable tethering during infusion or sampling. It features a molded elastomer saddle with a vented dome, a .062in ID 12in stainless‑steel spring tether to transmit torque to the swivel, and adjustable belly bands that ensure a secure yet comfortable fit as the animal grows.
Features
- .062in ID 12in stainless‑steel spring tether
- Molded elastomer saddle with vented protective dome
- Adjustable belly bands for proper fit and reduced stress
- Supports infusion or blood sampling in tethered mice
- Designed to connect directly to standard Instech swivels
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Replacement universal swivel-to-tether clamp for Instech swivels. Adjusts to tethers of range of sizes.
The Instech CLAMP is a universal swivel-to-tether clamp designed to secure spring tethers to various swivel models. This essential accessory provides a reliable mechanical connection between the swivel and the protective tether, ensuring that the fluid line remains protected even during animal movement. It is compatible with a wide range of Instech spring tethers and stainless steel swivels, making it a versatile component for rodent infusion setups.
Features
- Application: Secures spring tethers to dual or single channel swivels
- Compatibility: Mates with all Instech spring tethers and VAB™ systems
- Design: Universal fit for 20ga, 22ga, and 25ga stainless steel swivels
- Function: Prevents tether detachment during high-activity research
- Material: Durable construction for repeated use and autoclaving
- Packaging: Available in convenient packs of five
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech Rodent stand for ABS2 units with swivel lever arm and IV bag holder.
The Instech ABS2/R Stand is an optional accessory for the Instech ABS2™ automated blood sampler designed to position the sampler unit directly above a standard rodent cage. This configuration is intended to facilitate hand-free automated blood sampling from a swivel and tether system on freely-moving catherized rodents while minimizing tubing dead volume. The stand ensures proper positioning to reduce stress on the animal and minimize the length of the fluid lines, which helps with the accuracy of microsampling.
Features
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech 22ga single channel Plastic Swivel (blue), luer inlet, sterile
Plastic Swivels
For Tethered Infusion or Sampling with Mice and Rats
Plastic Swivels from Instech deliver reliable, cost‑effective performance designed for researchers who prefer fresh fluid‑path components, these swivels feature durable plastic bodies paired with the same proven self‑adjusting seals used in our stainless‑steel models—ensuring smooth, leak‑free operation through even long‑term studies.
Each swivel includes a convenient clamp for quick connection to standard Instech spring tethers, with color‑coded bodies for easy gauge identification. Available in three sizes, with or without luer inlets, and supplied EtO‑sterilized or integrated into ready‑to‑use infusion kits. Compatible with PS95 rat and PS62 mouse tethers.
- One channel for infusion or sampling
- Self-adjusting seals
- Includes plastic swivel-to-tether clamp (22ga mate with PS95-based rat tethers)
- Individually packaged and EtO sterilized
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech Very-low-flow peristaltic pump, 10683:1 motor delivers flow rates from 0.8-200l/min.
The Instech P720/10K is the very-low-flow model in the P720 series of compact peristaltic pumps. It is designed to deliver the precise, pulse-free flow rates of a syringe pump for applications like microdialysis and mouse infusion without the volume limitations of a syringe. Its analog circuitry is specifically designed to minimize electromagnetic radiation for use near sensitive intracellular recordings.
Features
- Type: Very-low-flow miniature peristaltic pump
- Flow Rate Range: 0.8 µL/min to 200 µL/min (0.05 to 12 mL/hr) depending on tubing size
- Accuracy: Better than ±5% with linear speed control (0-100 dial)
- Construction: Precision-machined pump head with a Swiss-made motor and spur gearhead
- Power Source: Universal 15VDC AC adapter or internal 9V lithium battery backup
- Compatibility: Mates with single and dual-channel P720 tube sets
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Instech Multi-syringe rack with withdrawal bracket, 6-10 for Harvard Apparatus PHD Ultra, upgrade at purchase (703024A)
The HA3024A is a multi-syringe rack upgrade for the Harvard Apparatus PHD Ultra™ syringe pump. This hardware expansion includes a withdrawal bracket, allowing the pump to perform both infusion and withdrawal across multiple syringes simultaneously. It is designed to significantly increase throughput by holding up to ten smaller syringes or six larger syringes, making it an essential tool for high-capacity rodent infusion or sampling studies.
Features
- Application: High-capacity multi-syringe infusion and withdrawal
- Compatibility: Designed for PHD Ultra™ series syringe pumps
- Capacity: Holds up to ten 0.5ml–20ml syringes or six 30ml–60ml syringes
- Function: Includes a withdrawal bracket for bidirectional fluid movement
- Efficiency: Increases study throughput by dosing multiple subjects at once
- Installation: Factory-installed upgrade when ordered at the time of pump purchase
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
SAI Infusion Technologies 1cc Syringe with attached 23G0.5"" Blunt - Sterile, 25/pack
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This item has a minimum qty of 2 per supplier requirements.
This sterile 1cc syringe comes with SAI's 23G x 0.5 in. blunt needle already attached, making it easy to maintain sterility while accessing catheters. Ideal for long-term infusion studies requiring flushing and locking of catheters. 25/pk. Product is for laboratory animal research only. ** If a COA is required it must be requested when the order is placed or a $50.00 fee will be apply. Contact Thermo Fisher Customer Service at 800-766-7000 to request to COA. **
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Automate Scientific Inc Brain Slice Keeper 4 – Quad
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Slices maintained for many hours in incubating media - Four separate rings allow separation of different types of preparations - Slices supported on a quick change nylon net. The BSK4 Brain Slice Keeper has been designed to pre-incubate a large number brain slices prior to transfer into recording chambers or for the incubation of preparations in experimental test media. Based on the BSK1, it consists of four closely fitting acrylic rings, located in a circular manifold, between which is wedged a removable sheet of nylon netting. In operation, the four rings located on a manifold with netting are totally immersed in an ACSF-filled purpose designed holding vessel into which a 95% O2, 5% CO2 gas mixture is supplied through a ceramic bubbler.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More