Filtered Search Results
MilliporeSigma™ Glass Fiber Filters Without Binder, 1.6 μm
Hydrophilic Glass Fiber without Binder Resin filter
| Type | Membrane Filter |
|---|---|
| Material | Glass Fiber |
| Filter Type | Microfilter |
| Sterility | Non-sterile |
MilliporeSigma™ Reinforced Membrane Filters
Contain no asbestos or fiberglass; made from non-shedding materials.
| Pore Size | 0.5 μm |
|---|---|
| Temperature (English) Max. | 158°F |
| Temperature (Metric) Max | 70°C |
| Color | White |
| Material | Polymers of Cellulose Ester |
| Hydrophobicity | Hydrophilic |
| Sterility | Sterile |
| Thickness (Metric) | 200 μm |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Thickness (English) | 0.007 in. |
| Filter Type | Screen Filter |
| Surface Type | Plain |
| Autoclavable | Autoclavable |
MilliporeSigma™ Glass Fiber Filters Without Binder, 2.7 μm
Hydrophilic Glass Fiber without Binder Resin filter
| Pore Size | 2.7 μm |
|---|---|
| Particle Retention | 2.7 μm |
| Temperature (English) Max. | 932°F |
| Airflow Rate | 139 L/min/ cm2 |
| Air Resistance | 16 mm of H2O |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Grade | APFD |
| Material | Borosilicate Glass Microfiber |
| Hydrophobicity | Hydrophilic |
| For Use With (Application) | Use for clarifying suspensions containing particulates |
| Sterility | Sterile |
| Thickness (Metric) | 470 μm |
| Flow Rate | 2.7 mL/min/ cm2 |
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Thickness (English) | 0.018 in. |
| Filter Type | Depth Filter |
| Surface Type | Plain |
| Autoclavable | Autoclavable |
MilliporeSigma™ Glass Fiber Filters Without Binder, 1 μm
Hydrophilic Glass Fiber without Binder Resin filter
| Thickness (Metric) | 700 μm |
|---|---|
| Wettability | Hydrophilic |
| Type | Filter Membranes |
| Temperature (Metric) Max | 500°C |
| Color | White |
| Grade | APFB |
| Filter Type | Depth Filter |
| Surface Type | Plain |
| Autoclavable | Autoclavable |
| Sterility | Sterile |
Cytiva Whatman™ Glass Fiber Filter Papers - Grade 31
Offers fine particle retention and high flow rate, as well as good loading capacity
Cytiva™ Whatman™ Grade GF/F Glass Microfiber Filters, Binder-free
Binder-free borosilicate glass microfiber filter used for DNA purification, protein precipitation, and landfill leachate toxicity testing.
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Sheets
Designed for analysis of non-filterable residue and materials that require a high loading capacity glass microfiber filter. Whatman™ Binder-Free Glass Microfiber Filters, Grade 934-AH Sheets are also used in cell harvesting, liquid scintillation, and monitoring pollution.
| Particle Retention | 1.5 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Sheet |
| Description | Whatman Grade 934-AH borosilicate glass microfiber filters from GE are smooth water quality filters with high retention efficiency. Grade 934-AH filters are often used in total suspended solids analysis. |
| Filtration Time | 47 sec./100mL |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pack |
| Grade | Grade 934-AH |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial culturesUsed for a wide range of laboratory applications.It is recommended for water pollution monitoring, cell harvesting, liquid scintillation count |
| Thickness (Metric) | 435 μm |
| Flow Rate | 3.7 sec./100mL/in.2 |
| Type | Filter for Total Suspended Solids Analysis |
| Basis Weight | 64 g/m2 |
| Format | Sheet |
| Thickness (English) | 0.017 in. |
| Surface Type | Smooth |
| Waterflow Rate | 341 mL/min |
Ahlstrom™ Glass Microfiber Filter Papers - Grade 161
Ahlstrom Grade 161 is a binder-free microfiber glass filter that offers finer particle retention and higher flow rate than traditional analytical papers.
| Thickness (Metric) | 0.32 mm |
|---|---|
| Flow Rate | 3.6 cfm/ft2 |
| Particle Retention | 1.1 μm |
| Temperature (English) Max. | 932°F |
| Format | Disc |
| Thickness (English) | 0.012 in. |
| Temperature (Metric) Max | 500°C |
| Grade | 161 |
| Material | Borosilicate Glass |
| For Use With (Application) | Fine porosity and high flow for TSS, cell harvesting, and general laboratory applications |
Fisherbrand™ Filters for TCLP
Binder-free, borosilicate glass fiber filters have 0.7 micron pore size
| Pore Size | 0.7 μm |
|---|---|
| Material | Borosilicate Glass Fiber |
Ahlstrom-Munksjo Standard Glass Microfiber Filter Papers, Grade 141
Glass microfiber filter recommended for pre-filtration of membrane filters and is also used in combination with Grade 121 as a highly efficient protective and retentive grade density pre-filter for membrane filters.
GVS Glass Microfiber Filter, 2.7 μm
GVS Glass Microfiber Filters are binder-free with a GSM of 120 g/m2.
| Pore Size | 2.7 μm |
|---|---|
| Type | Membrane Filter |
| Material | Glass Fiber |
| Filter Type | Microfilter |
| Sterility | Non-sterile |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A Sheets are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Sheet |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Sheet |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/B Sheets
Filters fine particles with high wet-strength and high loading capacity. Whatman™ Binder-Free Microfiber Filters, Grade GF/B Sheets are particularly useful for liquid clarification and liquid scintillation counting.
| Thickness (Metric) | 675 μm |
|---|---|
| Flow Rate | 5.5 sec./100 mL |
| Type | Filter |
| Temperature (English) Max. | 932°F |
| Basis Weight | 143 g/m2 |
| Format | Sheet |
| Thickness (English) | 0.02 in. |
| Temperature (Metric) Max | 500°C |
| Material | Borosilicate Glass |
| Type | Membrane Filter |
|---|---|
| Format | Roll |
| Diameter (Metric) | 30 mm |
| Material | Glass Fiber |
| Filter Type | Microfilter |
| Sterility | Non-sterile |