Syringeless and Syringe Filters
- (2)
- (8)
- (16)
- (376)
- (9)
- (94)
- (1)
- (489)
- (1)
- (1)
- (15)
- (16)
- (2)
- (5)
- (23)
- (1)
- (15)
- (1)
- (3)
- (5)
- (2)
- (1)
- (3)
- (3)
- (26)
- (3)
- (1)
- (1)
- (1)
- (14)
- (4)
- (1)
- (2)
- (8)
- (76)
- (4)
- (19)
- (4)
- (4)
- (1)
- (44)
- (1)
- (19)
- (2)
- (150)
- (110)
- (3)
- (1)
- (116)
- (43)
- (52)
- (128)
- (28)
- (4)
- (2)
- (1)
- (8)
- (2)
- (5)
- (4)
- (6)
- (11)
- (73)
- (25)
- (635)
- (174)
- (9)
- (525)
- (6)
- (15)
- (1)
- (4)
- (2)
- (12)
- (1)
- (6)
- (2)
- (5)
- (158)
- (8)
- (12)
- (1)
- (8)
- (82)
- (3)
- (1)
- (8)
- (2)
- (18)
- (2)
- (1)
Filtered Search Results
| Outlet Style | Male Leur-Slip |
|---|---|
| Diameter (Metric) | 33 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Acrylic |
| Material (Membrane) | PES |
| Quantity | 50/Pk. |
| Sterility | Sterile |
MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
| Pore Size | 0.22 μm |
|---|---|
| Disposable | Single-use |
| Temperature (English) Operating | 113°F |
| Housing Material | Hydrophilic PES |
| Material (Membrane) | PES |
| Color | Green |
| Volume (Metric) | <10 mL |
| Pressure Rating | 145 psi |
| For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
| Sterility | Sterile |
| Type | Modified Acrylic Syringe Filter |
| Outlet Style | Male Luer Slip |
| Diameter (Metric) | 3.3 cm |
| Inlet Style | Female Luer Lock |
| Tip Material | Modified Acrylic |
| Temperature Range (English) | 113°F |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
| Hold up Volume (After Air Purge) | <100 μL |
MilliporeSigma™ Medical Millex™-GP Syringe Filter Unit, 0.22 μm
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions
Cytiva Whatman™ Puradisc 13mm PTFE Syringe Filters
Employs a hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 13mm PTFE Syringe Filters are mainly used for filtration of non-aqueous samples.
| Type | Syringe Filter |
|---|---|
| Dimensions (L x W x H) | 16.3 x 19.8 mm |
| Outlet Style | Male Luer |
| Diameter (Metric) | 13 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Polypropylene (PP) |
| Material (Membrane) | PTFE |
| Volume (Metric) | Up to 10 mL |
| Pressure Rating | 5.2 bar (75 psi) |
| Material | PTFE |
| Hold up Volume (After Air Purge) | ≤25 μL |
| Sterility | Non-sterile |
| Filtration Area | 1.3 cm2 |
Cytiva Whatman™ Puradisc 25mm PTFE Syringe Filters
Contains hydrophobic membrane that is chemically stable and inert. Whatman™ Puradisc 25mm PTFE Syringe Filters exhibit low protein binding, and its main application is filtration of non-aqueous samples.
| Type | Syringe Filter |
|---|---|
| Dimensions (L x W x H) | 22.9 x 28.4 mm |
| Outlet Style | Male Luer |
| Diameter (Metric) | 25 mm |
| Inlet Style | Female Luer Lock |
| Material (Membrane) | PTFE |
| Volume (Metric) | Up to 100 mL |
| Pressure Rating | 5.2 bar (75 psi) |
| Material | PTFE |
| For Use With (Application) | For HPLC, TLC, and GC sample clarification; HPLC solvent filtration |
| Sterility | Non-sterile |
| Filtration Area | 4.2 cm2 |
Fisherbrand™ Syringe Filters - Sterile
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Hold up Volume (After Air Purge) | Low |
Fisher Scientific Basix™ Syringe Filters, PTFE, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, PTFE, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | PTFE (Hydrophobic) |
| Sterility | Non-sterile |
MilliporeSigma™ Millex™ Syringe Filter, Durapore™ (PVDF), 0.45 μm
Remove particulates, reduce signal-to-noise ratios and maintain flat baselines. Millex™ Nonsterile 33 mm Syringe Filters are constructed of polyethylene housing with Durapore™ membranes for preparing samples for analysis. Available in two pore sizes.
| Pore Size | 0.45 μm |
|---|---|
| Disposable | Single-use |
| Filter Code | HV |
| Housing Material | Polypropylene |
| Material (Membrane) | PVDF |
| Volume (Metric) | <100 mL |
| Color Code | Yellow |
| For Use With (Application) | Analytical sample prep |
| Sterility | Non-sterile |
| Filtration Area | 4.5 cm2 |
| Type | Syringe Filter |
| Diameter (Metric) | 33 mm |
| Diameter (Metric) Filter | 33 mm |
| Filter Type | Syringe Filter |
| Hold up Volume (After Air Purge) | ≤80 μL |
| Product Line | Millex™ |
Thermo Scientific™ Titan3™ PTFE (Hydrophilic) Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust hydrophilic PTFE syringe filters.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Polypropylene |
| Material (Membrane) | PTFE (Hydrophilic) |
| Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
| For Use With (Application) | Sample Filtration: aggressive organic, highly basic, or hot solutions, transducer protectors; aqueous solutions after prewetting with an alcohol |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Titan3 |
Fisher Scientific Basix™ Syringe Filters, Nylon, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | Nylon |
| Sterility | Non-sterile |
Thermo Scientific Chromatography Choice™ PTFE (Hydrophilic) Syringe Filters
Use Choice PTFE Hydrophilic Syringe Filters to filter aggressive organic, highly basic or hot solutions. They can filter aqueous solutions without pre-wetting.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | PTFE (Hydrophilic) |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Thermo Scientific Chromatography Choice™ Nylon Syringe Filters
Use Thermo Scientific™ Choice™ Nylon Syringe Filters as the economic option for most general laboratory filtration, and for filtration of most HPLC samples.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | Nylon |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Cytiva Whatman™ GD/X Glass Fiber (GF) Syringe Filters
Processes three to seven times more sample volume than filters without prefilter. Whatman™ GD/X Glass Fiber (GF) Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Dimensions (L x W x H) | 21.6 x 29.8 mm |
| Outlet Style | Male Luer |
| Inlet Style | Female Luer Lock |
| Housing Material | Pigment free polypropylene (PP) |
| Volume (Metric) | ≤10 mL |
| Filter Type | Syringe Filter |
Sartorius Minisart™ NML Syringe Filters, Sterile
Provides fast and reliable filtration of small to medium volumes, complete with ready-to-connect filter units. Sartorius Minisart™ NML Syringe Filters, Sterile eliminate time consuming preparatory work, such as changing out the filter and cleaning the filtration system.
| Disposable | Single-use |
|---|---|
| For Use With (Equipment) | Syringe |
| Diameter (Metric) | 28 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Meta acrylate butadiene styrene polymerisate (MBS) |
| Volume (Metric) | 200 mL |
| Sample Volume | 1 to 200 mL |
| Filter Type | Syringe Filter |
| For Use With (Application) | Preparation of aqueous liquids |
| Hold up Volume (After Air Purge) | 0.15 mL |
| Sterility | Sterile |
| Filtration Area | 6.2 cm2 |
Sartorius Minisart™ PES Syringe Filters
Minisart™ PES with polyethersulfone (PES) is optimal for highest flow rates and a pH of 2 - 13. Type 1776D with a pore size of 0.22 μm can be used for sterile filtration and has a male luer slip outlet. Version ACK is individually packed and sterilized by ethylene oxide (EO).