General Spectrometer Accessories
- (1)
- (1)
- (1)
- (1)
- (2)
- (5)
- (5)
- (5)
- (14)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (10)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
Filtered Search Results
Glass Expansion Nickel Skimmer Cone, Xi, Xt, Copper Core for for Thermo Scientific X Series ICP-MS (3600811)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Nickel Micro-Skimmer Cone, Xi, Xt, Copper Core (3600811) ¿ Suitable for Thermo/VG X-Series ICP-MS. Provides high matrix tolerance. Ideal for applications with high total dissolved solids (TDS). Not recommended for samples containing hydrofluoric acid (HF). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. Use Skimmer ConeGuard (70-803-1028) to protect cone threads during cleaning. When not in use, keep cones stored in original packaging for protection.For samples containing HF, and other highly corrosive samples where acid concentration begin to exceed 5%, we recommend a platinum cone, see catalog number 501907721.For high performance and sensitivity, we recommend 501907719.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Skimmer Cone with Copper Base for Agilent 8900 with S lens (G3666-67401)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Skimmer Cone with Copper Base for s-lens (G3666-67401) ¿ For Agilent 8900 ICP-MS. Recommended for corrosive samples, including HF (e.g., routine aqueous environmental samples, >5% acid matrix, HF). More durable, longer-lasting, & because it runs hotter it requires less frequent cleaning. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. Use Skimmer ConeGuard (70-803-1004) to protect cone threads during cleaning. When not in use, keep cones stored in original packaging for protection.For routine applications, use standard Nickel Skimmer for x-lens, see P/N 501907593.For organic analysis, use Platinum Skimmer with Ni Base for x-lens, P/N 501907595, which must be mounted on brass adaptor skimmer base, see P/N AT7905X-BR. For lowest nickel background and laser ablation applications, use Aluminum Skimmer for x-lens, see P/N AT7902X-Al.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Sampler Cone for Agilent 7700/7800/7850/7900/8800/8900 ICP-MS (G3280-67036)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Sampler Cone (G3280-67036) ¿ For Agilent 7700/7800/7850/7900/8800/8900 ICP-MS. Standard with s-lens for semiconductor applications. Recommended for high TDS samples and for lower detection limits. Suitable for most applications, including corrosive samples (e.g., routine aqueous environmental samples, >5% acid matrix, HF, organic). Use with platinum skimmer cone and brass skimmer base. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For corrosive acids, including HF, use Pt Sampler with Ni Base, P/N 501907586. For high TDS samples causing rapid cone deposition, use Pt Sampler with Ni Base, P/N 501907585. For lowest Ni background & laser ablation applications, use Al Sampler, see AT7701-Al.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Skimmer Cone with Copper Base for s-lens (G3280-67064) Suitable for Agilent 7700s/7900
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Skimmer Cone with Copper Base for s-lens (G3280-67064) ¿ For Agilent 7700s/7900/8800 ICP-MS. Standard cone for use with s-lens, and must be mounted on the brass skimmer adaptor base. Recommended for corrosive acids, including HF and semiconductor samples. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. Use Skimmer ConeGuard (70-803-1004) to protect cone threads during cleaning. When not in use, keep cones stored in original packaging for protection.For routine applications, we recommend the standard Nickel Skimmer for s-lens, see catalog number 501907578. For organic analysis, use Pt Skimmer with Ni Base for s-lens, P/N 501907589, which must be mounted on brass adaptor skimmer base.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Gold for Varian Series 2
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Gold for Agilent (Varian) Liberty Series 2 and Vista Radial ICP-OES. Compatible with Agilent (Varian) Liberty Series 2 and Vista Radial ICP-OES. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Silver 501907313 and PTFE Coated Silver 501907314.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907315).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Sampler Cone with 10mm Insert for Shimadzu 2030 ICP-MS (220-95356-80, 211-90110)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Sampler Cone, 10 mm insert (211-90110, 220-95356-80) ¿ For Shimadzu 2030 ICP-MS. Suitable for most applications, including corrosive samples (e.g., routine aqueous environmental samples, >5% acid matrix, HF, organic). Although the highest cost option, it is typically the most durable, longest-lasting, and because it runs hotter it requires less frequent cleaning. Use a new Graphite Sampler Cone Gasket (SZ5001) each time the cone is re-installed, even if it¿s the same cone. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For routine samples, we recommend a nickel sampler cone, see catalog number 501907696.For extended life Pt sampler cone for corrosive samples, see catalog number 501907701 (15 mm Pt insert).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion OpalMist DC Nebulizer 0.4mL/min, Includes NFT-16-50 UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 piece), and 70-803-1449 Gas Fitting with Ratchet Nebulizer connector
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
OpalMist DC Nebulizer 0.4mL/min, includes UniFit Connector with 0.50mm ID x 1.6mm OD x 700mm long tubing (1 pc) & DC Gas Fitting Type 23 with ratchet connector (1 pc). Compatible with Perkin Elmer NexION 1000/2000/5000.Optimum nebulizer gas flow rate is 1.0L/min & sample flow rate is 0.4min. Recommended not to exceed optimum 0.4mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 1.0L/min gas flow rate. OpalMist is made from high purity PFA resulting in the lowest background & exceptional resistance to HF. Tolerates up to 15% TDS & 75um particulates.Replacement parts include P/Ns 502702959 & 501907305.Recommended nebulizer maintenance tools are Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Nickel Sampler Cone for Thermo Scientific Element 1/Element 2/Neptune ICP-MS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
100% Nickel Sampler Cone ¿ For Thermo/Finnigan Element 1, 2 & Neptune ICP-MS. Use for lowest Cu background, and suitable for most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic). Not recommended for samples containing hydrofluoric acid (HF). Use a new Graphite Sampler Cone Gasket (501907717) each time the cone is re-installed, even if it¿s the same cone. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For lowest boron background and semiconductor applications, we recommend a platinum cone, see catalog number 501907711.For high sensitivity applications and low matrix containing samples, we recommend Nickel Jet Sampler, see catalog number 501907709.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Sampler Cone with Solid Nickel Base for Agilent 7700/7800/7900/8800/8900 (G3280-67142)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Sampler Cone with Nickel Base ¿ For Agilent 7700/7800/7850/7900/8800/8900 ICP-MS. For use with aggressive acid matrices (e.g., HCl, HF, HClO4) and high matrix samples when cone deposition is rapid due to high TDS. Use with platinum skimmer cone and brass skimmer base. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For routine samples with x-lens, use P/N 501907575. For high viscosity or high boiling point acids (e.g., H2SO4, H3PO4), use Pt Sampler with 18 mm insert, see P/N 501907582. For lowest Ni background & laser ablation applications, use Al Sampler, see AT7701-Al.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion RF Coil Copper for PE Elan/NexION (WE021816, 8003-0559)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
RF Coil Copper for PerkinElmer & Fluidigm ICP-MS. Compatible with PerkinElmer Elan 6000/6100 & 6100 DRC, NexION 300/350 & Fluidigm Helios CyTOF & CyTOF2 ICP-MS. The RF coil is susceptible to corrosion in the torch box, which eventually lowers the conductivity of the coil. The greater the corrosion, the larger amount of energy is needed to produce a plasma of the same power. Coils in a corroded condition, increases the stress applied to other components in the RF generating system, and can shorten the lifetime of your torch. Copper is used as the base material of most commercially available coils but different plating materials are available. Silver has the best conductance & gold the best corrosion resistance. For Gold 501907331, Silver 501907332.To install your coil and ensure proper alignment, we highly recommend our re-useable RF Coil Installation Tool Kit (501907333).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Conikal Nebulizer 1mL/min with EzyFit & EzyLok, Includes EZTS-16-75 EzyFit Connector with 0.75mm ID x 1.6mm OD x 1500mm L tubing (1 unit)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Conikal Nebulizer 1.0 mL/min, includes EzyFit Connector with 0.75 mm ID x 1.6 mm OD x 1500 mm long tubing (1 piece) and EzyLok Connector (1 piece).Optimum nebulizer gas flow rate is 1.0 L/min and sample flow rate is 1.0 mL/min. Recommended not to exceed optimum 1.0 mL/min sample flow rate; however, lower gas and sample flow rates are OK. Backpressure should read approximately 30psi at 1.0 L/min gas flow rate. The Conikal nebulizer is a high-performance, general use glass nebulizer, that tolerates up to 5% TDS and 75um particulates. Replacement parts include P/Ns EZTS-16-75 and 502702994.Recommend nebulizer maintenance tools, Fluka RBS25 (P/N NC9000117) and Eluo Nebulizer Cleaning Tool (P/N NC9462559). When nebulizer is not in use, best to store in the provided hard plastic case.Consider upgrading to our new Direct Connect (DC) Conikal to take advantage of the cost-effective design improvements.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Gasket for PerkinElmer NexION 300/350/1000/1100/2000/2200/5000 ICP-MS Sampler Cone (W1040148)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Gasket for Sampler Cone, PKT 5 (W1040148). For PerkinElmer NexION 1000/2000/5000/300/350 ICP-MS. Use a new gasket each time the cone is re-installed, even if it is the same cone.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Meinhard Elemental Scientific AST connector for MEINHARD® Plus Series Nebulizer F2 (0.25mm i.d., greenmarker) Attaches to port #3 of the FAST valve, 30cm long
FAST connector for MEINHARD® Plus Series Nebulizer F2 (0.25mm i.d., greenmarker) Attaches to port #3 of the FAST valve, 30cm long
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Contour Flared End PVC Pump Tube 3tag, 72mm spacing, 0.25mm ID, Orange/Blue (PKT 6)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Contour Flared End PVC Pump Tube 3tag 0.25mm ID Orange/Blue (PKT 6).Tag Colors: Orange/BlueID mm: 0.25Wall Thickness mm: 0.91OD mm: 2.07Overall Length: 455mm (72mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide. Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Contour Flared End PVC Pump Tube 3tag, 72mm spacing, 0.19mm ID, Orange/Red (PKT 6)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Contour Flared End PVC Pump Tube 3tag 0.19mm ID Orange/Red (PKT 6).Tag Colors: Orange/RedID mm: 0.19Wall Thickness mm: 0.91OD mm: 2.01Overall Length: 455mm (72mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More