Glass Expansion Quartz Outer Tube for D-Torch, Arcos II EOP and MV
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Outer Tube for D-Torch. Compatible with Spectro (Ametek) ARCOS II EOP or MV Axial D-Torch (30-808-3657). The D-Torch, provides a robust and high-performing alternative to both single-piece and semi-demountable quartz torches, ensuring greater robustness and a lower cost of ownership. With the D-Torch design, the analyst most often replaces only the outer tube, rather than replacing the entire torch or a quartz torch body.When not in use, clean as per recommended guidelines, and store in original box.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC Preassembled Sealed Liquid Cell - CaF2, 0.2 mm
Sealed liquid cells have a corrosion-resistant construction, making them ideal for highly volatile samples. Each cell has a precise path length which is calibrated using the interference pattern generated by an empty cell in the beam of a spectrometer. These cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. They use a lead spacer which is amalgamated to the window material. The resultant bond forms a good leak-free seal which is effective in preventing evaporation and loss of sample. You can fill or empty liquid samples easily. The sealed liquid cell is an integral unit and cannot be disassembled. Rugged construction Easy to fill and clean Leak-free operation Calibrated for quantitative analysis Usable on all PerkinElmer FT-IR spectrometers
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC FIMS-400 FLOW INJECTION MERCUR
FIMS-400 FLOW INJECTION MERCUR
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Tapered Quartz Injector with ball joint 2.5mm (suitable for Elan DRC/NexION)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Tapered Injector with Ball Joint 2.5mm ID. A 2.5mm ID quartz tapered injector with ball joint for use with aqueous matrices, including samples with high TDS. Compatible with PerkinElmer ICP-MS Elan DRC, NexION 300/350 D-Torch (501906989) and standard torch. Not for use with HF. Suitable for torch adaptor 31-808-2824. Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Elegra Argon Humidifier
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Elegra Argon Humidifier. Compatible with Teledyne Leeman Series ICP-OES. An argon humidifier is commonly used in ICP analyses involving samples with high concentrations of dissolved solids. It helps to alleviate salt deposits in the nebulizer & torch injector, allowing uninterrupted & maintenance-free operation. Compact, durable, cost-effective design with a non-pressurized water reservoir, & no heating or electric power required. An easy-to-use bypass switch allows you to take the Elegra off-line without disconnecting argon lines. Highly efficient membrane humidification technology that consistently maintains signal stability for samples with high TDS. Inert & metal-free eliminates possibility of contamination. Simple to use & maintain with maximum & minimum fill lines ensuring you are always operating under optimum conditions.Replacement Elegra Membrane, P/N 70-803-1286. Optional Mount, P/N 70-803-1581.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-900
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Contour Flared End PVC Pump Tube 3tag, 72mm spacing, 2.79mm ID, Purple/White (PKT 6)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Contour Flared End PVC Pump Tube 3tag 2.79mm ID Purple/White (PKT 6).Tag Colors: Purple/WhiteID mm: 2.79Wall Thickness mm: 0.86OD mm: 4.51Overall Length: 455mm (72mm spacing between tags)Number of Tubes Per Pack: 6Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon R3603/R3607 or equivalent.Special Properties: Inexpensive all-around tubing for general laboratory applicationsChemical Compatibility: Excellent for aqueous solutions of the following acids and concentrations, up to 35% Nitric Acid, up to 37% Hydrochloric Acid, up to 25% Hydrofluoric Acid, up to 30% Hydrogen Peroxide.Limitations: Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Ceramic Outer Tube for 5100/5110 SVDV/VDV D-Torch
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ceramic Outer Tube for D-Torch. Compatible with Agilent 5000 Series SVDV/VDV D-Torch (30-808-3560). Compared to quartz outer tubes, the ceramic alternative has an extended lifespan, significantly reducing maintenance, cleaning, and downtime caused by torch failure. Incorporating a ceramic outer tube into your ICP torch has a range of benefits, particularly for the analysis of high-TDS sample matrices, fusions, wear metals in oil, hydrofluoric acid (HF) and volatile organics. In addition to providing durability, the ceramic outer tube on an ICP torch produces a hotter, more robust plasma, which reduces matrix effects and improves sensitivities and detection limits, compared to a quartz torch.When not in use, clean as per recommended guidelines, and store in original box.Optional quartz outer tube P/N NC2125299.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion OpalMist Nebulizer 0.1mL/min, Includes NFT-16-25 UniFit Connector with 0.25mm ID x 1.6mm OD x 700mm long tubing (1 piece), EL-1 EzyLok Connector Kit, and 70-803-0911 Ratchet EzyLok Connector.
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
OpalMist U-Series Nebulizer 0.1mL/min, includes UniFit Connector with 0.25mm ID x 1.6mm OD x 700mm long tubing (1 pc) & EzyLok Connector (1 pc).Optimum nebulizer gas flow rate is 0.7L/min & sample flow rate is 0.1mL/min. Recommended not to exceed optimum 0.1mL/min sample flow rate; however, lower gas & sample flow rates are OK. The backpressure should read ~40 psi at 0.7L/min gas flow rate. OpalMist is made from high purity PFA resulting in the lowest background & exceptional resistance to HF. Tolerates up to 15% TDS & 75um particulates.Replacement parts include P/Ns NFT-16-25, EL-1 & 501907289.Recommended nebulizer maintenance tools, Fluka RBS25 (P/N NC9000117) & Eluo Nebulizer Cleaning Tool (P/N 501907353). When nebulizer is not in use, best to store in the provided hard plastic case.Consider upgrading to our new Direct Connect (DC) OpalMist to take advantage of the cost-effective design improvements.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Solva Flex Pump Tube 3 tag , 95mm spacing, 0.89mm ID, Orange/Orange (PKT 12)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Solva Flex Pump Tube 3tag, 95mm spacing, 0.89mm ID Orange/Orange (PKT 12).Tag Colors: Orange/OrangeID mm: 0.89Wall Thickness mm: 0.86OD mm: 2.61Overall Length: 455mm (95mm spacing between tags)Number of Tubes Per Pack: 12Physical Properties: Thermoplastic, PVC based material with plasticizerMaterial: Made from Tygon 4040 or equivalent.Special Properties: Special tubing for hydrocarbons, petroleum products and distillates.Chemical Compatibility: Ideal for gasoline, kerosene, heating oils, cutting liquids and coolants based on glycols.Limitations: Not recommended for strong acids and alkalis, foodstuffs, beverages and medicines. Potential leaching of plasticizersGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Quartz Injector 1.2mm
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Quartz Injector with 1.2mm ID.A 1.2mm ID Quartz Injector (48807022), designed for volatile organic solvents and non-HF matrices. Compatible with Spectro Blue SOP Semi Demountable Torch (SDT) 50-190-7218 (31-808-3405), Spectro Blue EOP SDT 50-190-7217 (31-808-3394) and Spectro Blue TI SDT 50-190-7225 (31-808-3468).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Graphite Gasket for Agilent 7700/7900/8800/8900 Sampler Cone, PKT 3 (G3280-67009)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Graphite Sampler Cone Gasket, PKT 3 (G3280-67009). For Agilent 7700/7900/8800/8900 ICP-MS. Use a new gasket each time the cone is installed, even if it is the same cone.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Perkin Elmer US LLC Single Slot Burner Head for PerkinElmer AAnalyst Series Spectrometers, Slot Length: 10cm, Flame Type: Air-Acetylene
The 10 cm burner head is designed to be used with the air-acetylene flame. Because of its long burner path length, it provides the best sensitivity for air-acetylene elements.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Gas Fitting with Ratchet Nebulizer Connector for Shimadzu 9000/9800
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Direct Connect (DC) Nebulizer Gas Fitting Type 41. Contains Ratchet Connector Gas Line 14-28 x 500 Assembly (70-803-1505) and ICP Gas Inlet Fitting. For argon gas connection between DC nebulizer and instrument argon gas supply fitting. Suitable for A41- DC Nebulizers. Compatible with all Shimadzu ICP-OES and ICP-MS.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Platinum Sampler Cone (Boron-Free) for PerkinElmer NexION 300/350/1000/1100/2000/2200/5000 ICP-MS
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Platinum Sampler Cone, Boron-Free ¿ For PerkinElmer NexION 1000/2000/5000/300/350 ICP-MS. Suitable for applications requiring low boron background, including corrosive samples (e.g., routine aqueous environmental samples, >5% acid matrix, HF, organic). Replace Sampler Cone Gasket each time the cone is installed, even if it is the same cone (501907691). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection. Use Sampler ConeGuard to protect cone threads during cleaning, 70-803-1024.For most common applications (e.g., routine aqueous samples, <5% acid matrix, non-HF, non-organic) we recommend Nickel Sampler Cones, see catalog number 501907684. For corrosive samples use Platinum Sampler Cones, see catalog number 501907686.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Glass Expansion Tapered Alumina Injector 2.0mm
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Alumina Tapered Injector with 2.0mm ID. 2.0mm ID tapered alumina injector (N0775177). This alumina injector is for use with PerkinElmer Optima 2x00/4x00/5x00/7x00 DV ICP-OES series instruments. Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. They are also used with less volatile organic solvents, e.g., xylene.PerkinElmer Optima 2x00/4x00/5x00/7x00 DV ICP-OES series Injectors - Compatible with 50-190-7006 (30-808-0845), 50-190-7010 (30-808-1122), 50-190-7019 (30-808-1470), 50-190-7022 (30-808-2926), 50-904-7597 (N0772005), 50-904-3780 (N0770338, PG31016), 50-904-3781 (N0770344).Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More