Cell Counting Devices
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (8)
- (1)
- (1)
- (26)
- (3)
- (1)
- (1)
- (3)
- (3)
- (3)
- (1)
- (5)
- (4)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (7)
- (1)
- (1)
- (2)
- (4)
Filtered Search Results
Sigma Aldrich Fine Chemicals Biosciences Bright-LineTM Hemacytomete1EA
The Bright-Line(TM) Hemacytometer is molded from a single piece of thermal and shock-resistant glass. An H-shaped moat forms two counting areas or plateaus. A V slash at the loading side of each plateau facilitates charing and reduces the possibility of overflow into the moat. Each plateau features enhanced Neubauer rulings.The ruled surface is 0.1mm below the cover glass limiting the volume of blood or fluid over a square mm at 0.1cu.mm and over each of 400 squares (within the central square mm) to 0.00025 cu. mm. Contact of the flat polished cover glass surfaces with cover glass supports produces an exact volume of fluid over the counting area. The difference in surface tension characteristics between the metallic surface on the chamber and the polished cover glass assures smooth capillarity for precise loading and more even cell distribution.Replacement cover slips sold separately Z375357
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Petroff Hausser Counting Chamber No Grid with Case
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
New one piece construction ensures durability and accuracy, featuring an improved Neubauer ruling on a single plateau (1/400 sq. mm). Designed for counting bacteria, sperm and blood platelets is offered in a series of cell-depths (10 and 20 microns). Cell-depth is 0.02 mm deep with 1.5 mm thick glass slide allows for the use of dark field microscopy.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
A-M Systems AM SYSTEMS INC
NC3966907 3000 AC/DC DIFFERENTIAL AMPLIF
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Bright-Line Leica Bright-Line Chamber Only
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Designed by Leica for accurate counting of blood cells platelets, dust/yeast cluster, and specimen samples. Sharp contrast from rhodium plated on "V-Load". Triple dividing lines clearly delineate counting area for accurate and precise results. Molded from a single piece of thermal and shock resistant glass with a polished chamber and cover glass assuring precise capillary loading and even cell distribution. Fluid volume is 0.1 mm cubed/mm squared and 0.00025 mm squared per each square.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Bright-Line Chamber Set
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Designed by Leica for accurate counting of blood cells platelets, dust/yeast cluster, and specimen samples. Sharp contrast from rhodium plated on "V-Load". Triple dividing lines clearly delineate counting area for accurate and precise results. Molded from a single piece of thermal and shock resistant glass with a polished chamber and cover glass assuring precise capillary loading and even cell distribution. Fluid volume is 0.1 mm cubed/mm squared and 0.00025 mm squared per each square. Cover glass, pipettes.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Double Neubauer Ruled Hemacytometer Complete Set (3520)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Double improved Neubauer rulings are diamond etched directly into a polished recess to reduce damage from scratches. Opaque surfaces above and below the counting area offer an easy focal reference. The chamber comes with a quick orientation mark for the microscope. 0.1 mm cell depth. Chamber with two 0.5mm cover glasses, pipettes, and case.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Bright-Line White Cell Pipette (Thoma)
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For Leica Bright-Line counting chamber.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences C-Chip C-Chip Hemacytometer Burker Turk
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
C-Chip disposable hemacytometer offers precise volume control and is easy use. Features quartz grade optical plastic, two counting chambers are fitted with clearest grid pattern, and continuous sample containment. Use for blood cell, bacteria, spore, and sperm counting. Precise design leads to highly reproducible results.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Taylor Wharton IC BIOMEDICAL LLC
NC3963031 CS200 8-THERMISTOR LEVEL SENSO
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Modulus Data Systems™ DIFFCOUNT™ III Electronic Differential Tally Counters
Microprocessor-controlled differential cell counter designed specifically for hematology laboratory
| Height (Metric) | 6cm |
|---|---|
| Depth (English) | 9 in. |
| Width (English) | 6 in. |
| Display Type | LCD |
| Depth (Metric) | 23cm |
| Wattage | 5w |
| Frequency | 50/60Hz |
| Width (Metric) | 15cm |
| Height (English) | 2.25 in. |
Hausser Scientific™ Bright-Line™ Counting Chamber PROMO
Diamond-etched counting chamber with double improved Neubauer ruling.
SKC, Inc. C-Chip™ Disposable Hemacytometers
A significant improvement over conventional glass hemacytometers
| Disposable | Single-use |
|---|---|
| Height (Metric) | 0.16cm |
| Width (English) | 1 in. |
| Length (Metric) | 7.5cm |
| Product Type | Hemacytometer |
| Length (English) | 2.95 in. |
| Material | Plastic |
| Width (Metric) | 2.5cm |
| Height (English) | 0.062 in. |
MilliporeSigma™ Scepter 2.0 Cytometer Sensors
Designed for use with the Scepter 2.0 Automated Handheld Cell Counter (cat. no. PHCC20040). Scepter 2.0 Cytometer Sensors ensure accurate, reproducible counts and eliminate pipetting errors and uneven sample loading. Available in two apertures to count cells between 4 and 25 μm.
| Analysis Time | <30 sec. |
|---|---|
| Test Methods | Automated |
| For Use With (Equipment) | Scepter 2.0 handheld automated cell counter |
| Product Type | Scepter Sensors |
| Sample Type | CHO cells, HeLa cells and mouse embryonic stem cells, can even be used to count subpopulations in peripheral Blood mononuclear cell preps |
| Memory | Stores up to 72 counts |
| For Use With (Application) | Counting cells and delivering histrogram profiles of cellular populations |
LW Scientific Digital Differential Counters
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
MedOne C-Chip™ Disposable Hemacytometers PROMO
A significant improvement over conventional glass hemacytometers.
| Disposable | Single-use |
|---|---|
| Height (Metric) | 0.16 cm |
| Depth (English) | 0.003 in. |
| Width (English) | 1 in. |
| Length (Metric) | 7.5 cm |
| Capacity (Metric) | 10 μL |
| Length (English) | 2.95 in. |
| Material | Plastic |
| Grid Type | Neubauer Improved |
| For Use With (Application) | Cell Counting |
| Width (Metric) | 2.5 cm |
| Thickness (Metric) | 0.16 cm |
| Product Type | Hemacytometer |
| Depth (Metric) | 0.01 cm |
| Height (English) | 0.062 in. |