Western Blot Substrates and Substrate Kits
- (1)
- (2)
- (12)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (4)
- (1)
- (6)
- (1)
- (1)
- (1)
- (6)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (8)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (9)
- (4)
- (1)
- (5)
- (38)
- (1)
- (1)
- (6)
- (1)
- (1)
- (2)
- (1)
- (2)
- (37)
- (33)
- (2)
- (9)
- (42)
- (2)
Filtered Search Results
Thermo Scientific™ SuperSignal™ West Femto Maximum Sensitivity Substrate
Ultra-sensitive enhanced chemiluminescent (ECL) HRP substrate for low-femtogram-level detection by Western blot analysis.
| Substrate | Horseradish Peroxidase |
|---|---|
| Form | Liquid |
| Product Type | Substrate |
| Signal Duration | 6 to 8 hr. |
| Product Line | SuperSignal |
| Detection Method | Chemiluminescence |
Thermo Scientific™ SuperSignal™ West Pico PLUS Chemiluminescent Substrate
Thermo Scientific SuperSignal West Pico PLUS Chemiluminescent Substrate is an enhanced chemiluminescent (ECL) horseradish peroxidase (HRP) substrate that enables picogram to high femtogram-level protein detection by western blot analysis.
| Shipping Condition | Room Temperature |
|---|---|
| Substrate | Horseradish Peroxidase |
| Recommended Antibody Concentrations | 2°: 1:20-100 K (10-50 ng/mL), 1°: 1:1 K (0.2-1 μg/mL) |
| Conjugate | HRP |
| Form | Liquid |
| Product Type | Substrate |
| Signal Duration | 6 to 24 hr. |
| For Use With (Application) | Western Blot |
| Product Line | SuperSignal |
| Detection Method | Chemiluminescence |
Thermo Scientific™ Pierce™ ECL Western Blotting Substrate
Value-priced, entry-level peroxidase substrate for enhanced chemiluminescence (ECL) that directly replaces costlier products without the need to re-optimize conditions.
| Substrate | Horseradish Peroxidase |
|---|---|
| Content And Storage | Upon receipt store at 2-8°C. Product is shipped at ambient temperature. |
| Form | Liquid |
| Product Type | Substrate |
| Signal Duration | 1 to 2 hr. |
| Product Line | Pierce |
| Detection Method | Chemiluminescence |
MilliporeSigma™ Immobilon™ Western Chemiluminescent HRP Substrate (ECL)
Provides high sensitivity over a broad detection range at an economical price
| Substrate | Horseradish Peroxidase |
|---|---|
| Content And Storage | 2°C to 8°C |
| Shelf Life | 9 Months |
| For Use With (Application) | Dot/Slot Blot |
Thermo Scientific™ SuperSignal™ West Dura Extended Duration Substrate
Luminol-based enhanced chemiluminescence (ECL) horseradish peroxidase (HRP) substrate ideal for quantitative western blotting with stable light output for mid-femtogram level detection for western blot analysis.
| Substrate | Horseradish Peroxidase |
|---|---|
| Sensitivity | Mid-femtogram |
| Form | Liquid |
| Product Type | Substrate |
| Signal Duration | 24 hr. |
| Product Line | SuperSignal |
| Detection Method | Chemiluminescence |
Thermo Scientific™ SuperSignal™ West Atto Ultimate Sensitivity Substrate
SuperSignal™ West Atto Ultimate Sensitivity Substrate is an enhanced chemiluminescent (ECL) substrate for high attogram protein detection and provides the high level sensitivity and better signal-to-noise ratios compared to other commercially available horseradish peroxidase (HRP) substrates.
| Shipping Condition | Wet Ice |
|---|---|
| Substrate | Horseradish Peroxidase |
| Sensitivity | Low-femtogram to high-attogram |
| Form | Liquid |
| Product Type | Substrate |
| Membrane Compatibility | Nitrocellulose, PVDF |
| For Use With (Application) | Western Blot |
| Product Line | SuperSignal |
| Detection Method | Chemiluminescence |
Thermo Scientific™ 1-Step™ Chloronaphthol Substrate Solution
1-Step™ Chloronaphthol Substrate Solution
Cytiva Amersham™ ECL™ Western Blotting Detection Reagents
Use for all routine Western blotting. Cytiva Life Sciences™ Amersham™ ECL™ Western Blotting Detection Reagents are the world's first commercially available chemiluminescent detection reagents and still one of the most widely used.
| Content And Storage | 2°C to 8°C |
|---|---|
| Sensitivity | ∼10 pg |
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Western Blot |
Thermo Scientific™ Pierce™ ECL 2 Western Blotting Substrate
Recommended HRP substrate for fluorescence imagers
| Content And Storage | 2°C to 8°C |
|---|---|
| Kit Contents | Detection reagent 1 and 2 |
| Product Type | ECL Western Blot Substrate |
Thermo Scientific™ Pierce™ ECL Plus Western Blotting Substrate
Acridan-based chemiluminescent and chemifluorescent HRP substrate for Western blot detection using X-ray film or CCD- or laser-based imagers.
| Content And Storage | Upon receipt store at 4°C. Product shipped on ice. |
|---|---|
| Sensitivity | Low picogram to mid-femtogram |
| Form | Liquid |
| Product Type | Substrate |
| Membrane Compatibility | Nitrocellulose, PVDF |
| Product Line | Pierce |
| Detection Method | Chemiluminescence, Fluorescence |
Cytiva Amersham™ ECL Select™ Western Blotting Detection Reagent
Use as a high sensitivity reagent for chemiluminescent Western blotting detection. Cytiva Life Sciences™ Amersham™ ECL Select™ Western Blotting Detection Reagent provides highly intense signal output, for detection of medium to very low protein levels.
Thermo Scientific™ Pierce™ DAB Substrate Kit
Chromogenic horseradish peroxidase (HRP) substrate for Western blot and tissue staining methods.
Thermo Scientific™ 1-Step™ Ultra TMB-Blotting Solution
Thermo Scientific™ 1-Step Ultra TMB-Blotting Solution is an enhanced single-component horseradish peroxidase (HRP) substrate for Western blotting and immunohistochemistry.
Thermo Scientific™ 1-Step™ NBT/BCIP Substrate Solution
Powders and ready-made nitro-blue tetrazolium and 5-bromo-4-chloro-3'-indolyphosphate solutions for chromogenic detection of alkaline phosphatase probes.
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |