Extraction Systems

DWK Life Sciences Kimble™ Kontes™ 10mL SLOW-DRY™ Concentrator Tube for Evaporative Concentrators Available on GSA/VA Contract for Federal Government customers only.

The SLOW-DRY™ concentrator tube reduces the risk of concentrating a sample to dryness.

PYREX™ Soxhlet Extractor with Standard Taper Joints, Body Only Available on GSA/VA Contract for Federal Government customers only.

Bulb in siphon tube near the top of tube facilitates cycling of the siphoning action

DWK Life Sciences Kimble™ Kimble™ Kontes™ Extractor Body for Heavier Than Water Continuous Liquid Extraction Apparatus

Replacement component of 584190-0000, this Extractor Body designed for EPA priority samples where the extracting solvent is heavier than water.

Fisherbrand™ Filtration Extraction Thimbles - Grade 645 Cellulose

Ensures complete extraction of samples, prevents contamination and minimize hands-on time

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Cellulose Soxhlet Extraction Thimbles, Single 1mm Wall

Manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Whatman™ Cellulose Soxhlet Extraction Thimbles are intended for applications including use in air and waste gas analysis.

Labconco™ Replacement Parts for Labconco™ Goldfisch Fat Extraction Apparatus

Replacement parts for Labconco Goldfisch Fat Extractor.

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ High Purity Glass Microfiber Soxhlet Extraction Thimbles

Designed to fit most Soxhlet extraction units. Whatman™ High Purity Glass Microfiber Soxhlet Extraction Thimbles are made of 100% borosilicate glass microfiber. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required.

DWK Life Sciences Kimble™ Kontes™ Soxhlet Extraction Body only, ST 45/50 24/40

Extractor body only, used as component part of 585050 Soxhlet extraction assemblies.

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Cellulose Soxhlet Extraction Thimbles, double 2mm wall

Manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Whatman™ Cellulose Soxhlet Extraction Thimbles are intended for applications including use in air and waste gas analysis.

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Grade 603 Cellulose Extraction Thimbles

Range in size and length to ensure optimal fit.. Whatman™ Grade 603 Cellulose Extraction Thimbles are for use with extracting pesticides from environmental samples and fat analysis in the food industry

DWK Life Sciences Wheaton™ Extractors For Soxhlet Extraction Apparatus

For continuous extraction of analytes from a solid into an organic solvent.

Synthware™ Soxhlet Extractor

For the extraction of solids with a suitable solvent

Synthware™ Friedrichs Condenser

Spiral inner tube with long vapor path provides good heat transfer and anti-flooding characteristics

Synthware™ Friedrichs Condenser

Spiral inner tube with long vapor path providing good heat transfer and anti-flooding characteristics

Foss™ Accessories for Soxtec™ Fat Extraction Systems: Viton condenser seals

For use with Soxtec™ 2055 system and discontinued systems

Synthware™ Concentrator Tube, Graduated

For use with Kuderna-Danish evaporative set-ups

Fisherbrand™ Filtration Extraction Thimbles - Grade 649 Glass Fibre

Ensures complete extraction of samples, prevents contamination and minimize hands-on time

PYREX™ Glass Extraction Thimbles Available on GSA/VA Contract for Federal Government customers only.

Resist attack by most chemicals

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ Glass Microfiber Extraction Thimbles, Grade 603G, without binder

Use for analysis of hot and acidic gases, including emission control and smoke tack gas monitoring. Whatman™ Glass Extraction Thimbles are designed to fit most Soxhlet extraction units and can be used with solvents that are incompatible with cellulose thimbles.

Cytiva (Formerly GE Healthcare Life Sciences) Whatman™ High-Purity Glass Thimbles

Use for pollution monitoring when analysis of hot and acidic gases is require. Whatman™ High-Purity Thimbles are designed to fit most Soxhlet extraction units and can be used with solvents that are incompatible with cellulose thimbles.

  spinner