Eppendorf™ 5702 Series Centrifuge

Low speed, general purpose units designed to meet the requirement of low- to mid-throughput clinical research and cell culture labs

Supplier:  Eppendorf™ 022628012

 View more versions of this product

Catalog No. 05-413-319


Add to Cart

Description

Description

Choose either the 5702 model - a base, non-heated centrifuge for standard applications, the 5702 R that is a refrigerated model for heat-sensitive samples, or the heated and refrigerated 5702 RH model for centrifugation under biological conditions to improve cell viability for more accurate results in downstream application like cell cultivation.
Features

  • Max. speed: 3,000 x g (4,400 rpm)
  • Very compact footprint to fit on every lab bench
  • Very quiet operation to benefit your environment
  • Low access height for simple loading and unloading of samples
  • SOFT brake function for slow acceleration and braking. Optimized for cell separation by gradient centrifugation
  • “At set RPM” function starts the timer when the selected rotational speed is reached for reproducible centrifugation runs
  • Key lock to prevent unintentional adjustments
  • Stainless steel rotor chamber is rust-free and easy to clean
  • Electronic imbalance detection for maximum safety
  • Optimizes air flow minimizes sample warming during run (5702)
  • FastTemp function for fast precooling (5702 R/RH)
  • Active heating guarantees high temperature accuracy during the entire centrifugation cycle (only 5702 RH)
  • ECO shut–off engages after 8 hours of nonuse to reduce energy consumption and extend compressor life (5702 R/RH)
  • Stainless steel rotor chamber is rust-free and easy to clean
  • Imbalance detection for maximum safety
  • Key lock to prevent accidental parameter changes
  • Aerosol–tight caps for safe centrifugation of hazardous samples optionally available

Additional Features for 5702 R and 5702 RH
  • Temperature settings from -9 to 40°C
  • FastTemp™ function for fast precooling
  • Standby cooling keeps the 5702 R at set temperature when lid is closed
  • ECO shut-off engages after 8 hours of non-use to reduce energy consumption and extend compressor life
  • Two program keys to store routine procedures
  • Active heating guarantees high temperature accuracy during the entire centrifugation cycle (only 5702 RH)

Packages
All packages include one centrifuge and a rotor. Other parts included may be a bucket, adapters, and rotary knobs. See ordering table for specifics of each package.

Order Info

Max. power requirements, Model 5702: 200w; Models 5702 R, RH: 380w. Power supply, all models: 230V 50Hz. Dimensions (L x W x H), Model 5702: 15.7 x 12.6 x 9.4 in. (40 x 32 x 24cm); Models 5702 R, RH: 22.8 x 15.0 x 10.2 in. (58 x 38 x 26cm). Weight, Model 5702: 44.0 lb. (20kg); Models 5702 R, RH: 79.4 lb. (36kg).

Compliance

Conform to CE, UL, cUL, IVD requirements

TRUSTED_SUSTAINABILITY
Specifications

Specifications

4 x 100 mL
4,400 rpm
5702R
25/25 sec.
SOFT brake function
Refrigerated Centrifuge
60 cm
120 V 50/60 Hz
3,000 x g
Centrifuge 5702 R, refrigerated, with Rotor A-4-38 incl. adapters for 13/16 mm blood collection tubes, rotary knobs
<45 dB(A) with Rotor A-4-38
0 to 99 min., with continuous run function
-9°C to +40°C
10.2 x 15 x 22.8 in. (26 x 38 x 58 cm)
79.4 lb. (36 kg)
380 w
SDS
Documents

Documents

Product Certifications
Promotions