Promotional price valid on web orders only. Your contract pricing may differ. Interested in signing up for a dedicated account number?
Learn More

Labconco™ Protector™ XL Floor-Mounted Fume Hoods: 6 ft. Width

Labconco Protector™ XL Floor-Mounted Fume Hood is suitable for general chemistry applications and accommodates oversized apparatus.

$22030.00 - $23640.00

Specifications

Electrical Requirements 115V, 60Hz, 10A, Domestic
Lighting LED
Width (Metric) 182.9cm
Height Overall (Metric) 241.3cm
Includes 2 Service fixtures, 1 GFCI duplexe
View More Specs

Products 3
Catalog Number Mfr. No. Depth (Metric) Weight (Metric) Price Quantity & Availability  
Catalog Number Mfr. No. Depth (Metric) Weight (Metric) Price Quantity & Availability  
11-261-7002
View Documents
Labconco™
112617002
95.8cm 310.7kg
Each for $22,030.00
Add to cart
 
11-262-7002
View Documents
Labconco™
112627002
111cm 317.5kg
Each for $23,150.00
Add to cart
 
11-263-7002
View Documents
Labconco™
112637002
141.5cm 322.1kg
Each for $23,640.00
Add to cart
 
Description

Description

  • By-pass airflow design
  • Dry powder, glacier white epoxy-coated steel exterior
  • Chemical-resistant molded composite panel liner and adjustable upper and lower baffles with flame spread less than 25 per ASTM E-84
  • Removable front and side panels and exterior and interior service access panels for access to plumbing and electrical wiring
  • Pre-wired LED lighting, light and blower switches for 115V, 60Hz operation
  • Tempered safety glass vertical-rising sashes framed with PVC
  • Factory prepared for up to eight service fixtures including two gooseneck faucets
  • Factory prepared for up to four electrical duplex receptacles
  • Shipped in multiple sections, top and bottom
  • ETL listed
Compliance
  • SEFA 1-2014 (Laboratory Fume Hoods)
  • NFPA 45-2011 (Fire Protection for Laboratories Using Chemicals) section 6-1 through 6-14
  • ASTM E84-14 Surface Burning Characteristics of Building Materials
  • ASHRAE 110-95 (Method of Testing Performance of Laboratory Fume Hoods)
  • ANSI Z9.5-2012 (Laboratory Ventilation)
  • UL 3101-1/61010-1
  • CAN/CSA C22.2 No. 1010.1
  • UL 1805
Specifications

Specifications

115V, 60Hz, 10A, Domestic
182.9cm
2 Service fixtures, 1 GFCI duplexe
LED
241.3cm
SDS
Product Certifications
Provide Content Correction

We continue to work to improve your shopping experience and your feedback regarding this content is very important to us. Please use the form below to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Cancel Submit