HPLC Columns and Cartridges
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Accucore™ C18 HPLC Columns
Use this column, with its specially designed solid core, for a broad range of nonpolar analytes across multiple applications.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 9% |
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| pH | 1 to 11 |
| Surface Area | 130 m²/g |
| Particle Shape | Solid Core |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
Retain and resolve polar analytes with highly aqueous mobile phases.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 12% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Polar |
| pH | 2 to 9 |
| Surface Area | 220 m²/g |
| USP Type | L1 |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| USP Type | L1 |
Thermo Scientific™ Shodex™ Asahipak Amino (NH2) Mixed Mode HPLC Column, 5 μm, 4.6 mm x 150 mm
Column Format: Standard Column; Pore Size: 100 Å; Column Phase: Reversed Phase, Normal Phase, Ion Exchange, HILIC
Thermo Scientific™ Acclaim™ 120 C8 HPLC Columns
Achieve exceptional performance and maximum resolution for reversed-phase separation of analytes with moderate hydrophobicity.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C8 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 300 m²/g |
| USP Type | L7 |
Thermo Scientific™ MAbPac™ Reversed Phase HPLC Columns
Use the new Thermo Scientific™ MAbPac™ RP columns for high-performance reversed-phase (RP) HPLC and LC/MS characterization of monoclonal antibodies (mAbs), fragments, variants, antibody drug conjugates (ADCs), PEGylated proteins, and bispecific proteins.
| Pore Size | 1500 Å |
|---|---|
| Particle Size | 4 μm |
| Phase | Reversed Phase |
| Max. Pressure | 4000 psi (275 bar) |
MilliporeSigma™ Supelco™ Ascentis™ Si HPLC Column, 3 μm Particle Size
The Ascentis™ Si is a high loading capacity silica with excellent peak shape. The Ascentis™ Si performs in both normal-phase and HILIC/ANP (aqueous normal phase) mode.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 3 μm |
| Stationary Phase | SIlica |
| Phase | Reversed Phase |
| Matrix | Silica Gel High Purity, Spherical/Silica Phase |
| Endcapped | No |
| pH | 2 to 6 |
| Technique | Fused-Core HPLC |
| Surface Area | 450 m2/g |
| Product Line | Ascentis |
MilliporeSigma™ Supelco™ SUPELCOSIL™ LC-18 HPLC Column, 3 μm Particle Size
A general purpose hydrophobic alkyl phase that is very retentive and gives good peak shape for a wide variety of compounds.
| Pore Size | 120 Å |
|---|---|
| Particle Size | 3 μm |
| Stationary Phase | C18 (Octadecyl) |
| Phase | Reversed Phase |
| Matrix | C18 (Octadecyl) Phase/Silica Gel, Spherical Particle Platform |
| Endcapped | Yes |
| Surface Area | 170 m2/g |
| Product Line | SUPELCOSIL |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns
Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
| Temperature | 50°C |
| Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
| Endcapped | Proprietary |
| Column Type | Mixed Mode |
| Green Features | FSC |
| Surface Area | 300 m²/g |
| Product Line | Acclaim |
| USP Type | L85 |
Thermo Scientific™ Aquasil™ 5μm C18 HPLC Columns, 5?m Particle Size
Thermo ScientificTM AquasilTM 5μm C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 12% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| For Use With | LC/MS |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 310 m²/g |
| USP Type | L1 |
| Column Format | Analytical Column |
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Accucore™ PFP HPLC Columns
Use these solid core particle columns to analyze difficult-to-resolve mixtures including DOA and pharmaceuticals.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 5% |
| Stationary Phase | PFP |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Ultrapure Silica |
| pH | 2 to 8 |
| Surface Area | 130 m²/g |
| Max. Pressure | 14500 psi (1000 bar) |
| Product Line | Accucore |
| USP Type | L43 |
Thermo Scientific™ MAbPac™ SCX-10 HPLC Columns
Use these strong cation-exchange columns for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | Nonporous |
|---|---|
| Temperature | Ambient to 60°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| pH | 2 to 12 |
Thermo Scientific™ NativePac OBE-1 SEC Column for Online Sample Preparation
Perform Native-MS analysis of biomacromolecules with the NativePac OBE-1 SEC Column designed for rapid exchange of non-volatile buffer components with a volatile buffer.