HPLC Columns
- (4)
- (1)
- (20)
- (8)
- (3)
- (5)
- (5)
- (17)
- (6)
- (1)
- (6)
- (2)
- (1)
- (250)
- (1)
- (6)
- (305)
- (12)
- (4)
- (1)
- (3)
- (1)
- (1)
- (205)
- (1,358)
- (2)
- (2)
- (161)
- (1)
- (1)
- (83)
- (20)
- (9)
- (80)
- (3)
- (906)
- (6)
- (2)
- (156)
- (14)
- (4)
- (440)
- (16)
- (1,626)
- (2)
- (1)
- (1)
- (7)
- (1)
- (79)
- (7)
- (36)
- (2)
- (9)
- (4)
- (30)
- (9)
- (83)
- (25)
- (1)
- (1)
- (9)
- (10)
- (11)
- (5)
- (323)
- (220)
- (1)
- (798)
- (3)
- (7)
- (1)
- (1)
- (146)
- (469)
- (948)
- (1)
- (55)
- (1)
- (74)
- (53)
- (1)
- (350)
- (25)
- (799)
- (114)
- (1)
- (21)
- (101)
- (1)
- (233)
- (25)
- (2)
- (3)
- (10)
- (1)
- (2)
- (10)
- (17)
- (2)
- (248)
- (55)
- (1)
- (724)
- (16)
- (1)
- (12)
- (15)
- (2)
- (3)
- (130)
- (1)
- (12)
- (4)
- (16)
- (2)
- (3)
- (26)
- (40)
- (89)
- (455)
- (25)
- (2)
- (33)
- (3)
- (13)
- (167)
- (29)
- (15)
- (12)
- (26)
- (138)
- (443)
- (62)
- (4)
- (1,127)
- (30)
- (28)
- (5)
- (2)
- (90)
- (24)
- (2,905)
- (3)
- (5)
- (23)
- (2)
- (24)
- (3)
- (19)
- (30)
- (4)
- (5)
- (56)
- (31)
- (21)
- (413)
- (41)
- (161)
- (34)
- (24)
- (129)
- (12)
- (2)
- (2)
- (13)
- (179)
- (114)
- (11)
- (1)
- (313)
- (2)
- (8)
- (7)
- (3,801)
- (124)
- (14)
- (3)
- (1)
- (10)
- (7)
- (4)
- (36)
- (1)
- (83)
- (31)
- (2)
- (11)
- (5)
- (163)
- (1)
- (6)
- (9)
- (1)
- (9)
- (4)
- (1)
- (1)
- (4)
- (1,319)
- (1)
- (3)
- (10)
- (469)
- (1)
- (2)
- (20)
- (1)
- (677)
- (21)
- (282)
- (1)
- (4)
- (21)
- (2)
- (147)
- (245)
- (5)
- (144)
- (3)
- (13)
- (136)
- (441)
- (49)
- (124)
- (6)
- (75)
- (54)
- (3)
- (63)
- (5)
- (198)
- (2)
- (30)
- (17)
- (9)
- (6)
- (5)
- (3)
- (105)
- (3)
- (2)
- (1)
- (5)
- (148)
- (1)
- (1)
- (621)
- (1)
- (8)
- (22)
- (90)
- (6)
- (11)
- (10)
- (2)
Filtered Search Results
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
| Carbon Load | 11% |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Aquasil™ 5μm C18 HPLC Columns, 5?m Particle Size
Thermo ScientificTM AquasilTM 5μm C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 12% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| For Use With | LC/MS |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 310 m²/g |
| USP Type | L1 |
| Column Format | Analytical Column |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns
Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| USP Type | L1 |
Thermo Scientific™ Accucore™ C18 HPLC Columns
Use this column, with its specially designed solid core, for a broad range of nonpolar analytes across multiple applications.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 9% |
| Stationary Phase | C18 |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| pH | 1 to 11 |
| Surface Area | 130 m²/g |
| Particle Shape | Solid Core |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
Retain and resolve polar analytes with highly aqueous mobile phases.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 12% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Polar |
| pH | 2 to 9 |
| Surface Area | 220 m²/g |
| USP Type | L1 |
Thermo Scientific™ MAbPac™ SCX-10 HPLC Columns
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Use these strong cation-exchange columns for high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | Nonporous |
|---|---|
| Temperature | Ambient to 60°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| pH | 2 to 12 |
Thermo Scientific™ Hypersil™ Chiral HPLC Columns
Resolve enantiomers with Hypersil Chiral HPLC columns in normal phase mode for confident purification of your target compound.
| Pore Size | 1000 Å |
|---|---|
| Temperature | Room Temperature |
| Packing Material | Spherical, Fully Porous Silica |
| Surface Area | 30 m²/g |
| Max. Pressure | 3700 psi (255 bar) |
| Column Format | Preparative Column and Analytical Column, Standard |
Thermo Scientific™ BetaSil™ C18 HPLC Columns, 5μm Particle Size
High surface area with high bonded phase coverage
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 20% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 310 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ PEI HILIC HPLC Columns
Retain highly polar and hydrophilic analytes, which are difficult to analyze with conventional C18 columns, using Hypersil GOLD PEI HILIC LC Columns.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 6% |
| Stationary Phase | PEI HILIC |
| Temperature | 60°C |
| Phase | HILIC |
| Endcapped | No |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
Thermo Scientific™ BetaBasic™ C8 Reversed Phase HPLC Column, 5 μm, 4.6 mm x 250 mm
Carbon Load: 7%; Pore Size: 150 Å; Column Phase: Reversed Phase
Thermo Scientific™ Accucore™ Phenyl-Hexyl HPLC Columns
Use this solid core column for fast, high-resolution separations of aromatic and moderately polar compounds.
| Pore Size | 80 Å |
|---|---|
| Particle Size | 2.6 μm |
| Carbon Load | 5% |
| Temperature | 70°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Ultrapure Silica |
| pH | 2 to 8 |
| Surface Area | 130 m²/g |
| Particle Shape | Solid Core |
| Max. Pressure | 14500 psi (1000 bar) |
| Product Line | Accucore |
| USP Type | L11 |
Thermo Scientific™ BioBasic™ 8 HPLC Columns
Use this column for reversed-phase separation of proteins and other biomolecules.
| Pore Size | 300 Å |
|---|---|
| Particle Size | 5 μm |
| Carbon Load | 5% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 100 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| Product Line | BioBasic |
| USP Type | L7 |
Thermo Scientific™ Syncronis™ C18 Columns
Use for hydrophobic interaction reversed-phase separations.
| Pore Size | 100 Å |
|---|---|
| Carbon Load | 16% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 320 m²/g |
| USP Type | L1 |