HPLC Columns
- (4)
- (1)
- (16)
- (9)
- (3)
- (3)
- (5)
- (18)
- (6)
- (5)
- (6)
- (1)
- (2)
- (10)
- (250)
- (1)
- (1)
- (2)
- (9)
- (304)
- (10)
- (2)
- (2)
- (1)
- (1)
- (1)
- (205)
- (1,347)
- (4)
- (4)
- (162)
- (1)
- (1)
- (83)
- (20)
- (9)
- (90)
- (900)
- (1)
- (13)
- (2)
- (162)
- (12)
- (4)
- (440)
- (17)
- (1,597)
- (2)
- (2)
- (8)
- (1)
- (86)
- (7)
- (35)
- (2)
- (9)
- (3)
- (30)
- (9)
- (83)
- (1)
- (25)
- (1)
- (9)
- (10)
- (11)
- (5)
- (320)
- (222)
- (1)
- (789)
- (7)
- (1)
- (1)
- (146)
- (459)
- (971)
- (1)
- (56)
- (1)
- (72)
- (53)
- (1)
- (351)
- (25)
- (811)
- (114)
- (1)
- (21)
- (101)
- (1)
- (223)
- (24)
- (2)
- (3)
- (10)
- (1)
- (2)
- (10)
- (11)
- (2)
- (241)
- (63)
- (1)
- (728)
- (12)
- (1)
- (9)
- (15)
- (2)
- (3)
- (130)
- (1)
- (11)
- (5)
- (16)
- (2)
- (3)
- (27)
- (39)
- (87)
- (440)
- (25)
- (2)
- (33)
- (3)
- (13)
- (167)
- (29)
- (15)
- (12)
- (6)
- (139)
- (446)
- (13)
- (4)
- (1,129)
- (30)
- (22)
- (3)
- (2)
- (1)
- (80)
- (24)
- (2,873)
- (10)
- (5)
- (2)
- (24)
- (2)
- (24)
- (17)
- (27)
- (5)
- (4)
- (1)
- (1)
- (4)
- (1,181)
- (3)
- (1)
- (4)
- (4)
- (456)
- (19)
- (648)
- (18)
- (276)
- (3)
- (12)
- (2)
- (144)
- (261)
- (5)
- (141)
- (2)
- (13)
- (141)
- (450)
- (49)
- (125)
- (5)
- (70)
- (5)
- (6)
- (3)
- (63)
- (5)
- (191)
- (11)
- (7)
- (8)
- (6)
- (84)
- (3)
- (1)
- (5)
- (147)
- (1)
- (1)
- (629)
- (22)
- (89)
- (7)
- (7)
- (13)
- (11)
- (412)
- (41)
- (105)
- (35)
- (14)
- (131)
- (11)
- (2)
- (2)
- (13)
- (210)
- (77)
- (10)
- (1)
- (227)
- (2)
- (8)
- (45)
- (3,451)
- (65)
- (13)
- (3)
- (1)
- (1)
- (9)
- (7)
- (3)
- (29)
- (83)
- (31)
- (2)
- (11)
- (4)
- (71)
- (1)
- (4)
- (4)
- (1)
Filtered Search Results

TSKgel™ Protein C4-300 HPLC Column, 3 μm Particle Size, Sold by MilliporeSigma™ Supelco™
TSKgel™ Protein C4-300 high efficiency columns are designed for the optimal recovery and resolution of proteins such as recombinant proteins, antibody fragments or PEGylated proteins.
Particle Size | 3 μm |
---|---|
Solvents | 0 to 100% organic solvent |
Flow Rate | 1 mL/min. |
Carbon Load | 3% |
Stationary Phase | C4 (butyl) |
Temperature | 10°C to 50°C |
Phase | Reversed Phase |
Matrix | Spherical Silica |
Endcapped | Yes, Trimethylsilane |
pH | 1.5 - 7.5 |
Material | Stainless Steel |
Product Line | TSKgel |
USP Type | L26 |
MilliporeSigma™ Supelco™ Ascentis™ Express 90 Å AQ-C18 HPLC Column, 2.7 μm Particle Size
A high-speed, high-performance liquid chromatography column based on the Fused-Core™ particle design.
Pore Size | 90 Å |
---|---|
Particle Size | 2.7 μm |
Carbon Load | 6.7% |
Phase | Reversed Phase |
Matrix | AQ-C18 Phase/Fused-Core™ Silica Particle Platform |
Endcapped | Yes |
pH | 2 to 9 |
Technique | Fused-Core HPLC |
Surface Area | 135 m2/g |
Product Line | Ascentis |
USP Type | L1 |
Thermo Scientific™ POROS™ R2 10 μm Column, Stainless Steel, 2.1 x 100 mm, 0.3 mL
Thermo Scientific™ POROS™ Prepacked Reversed-Phase Column. POROS R2 is a 2000 angstrom pore size Poly[styrenevinylbenzene] particle, suitable for the reversed-phase separation of biomolecules.
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns

Retain and resolve polar analytes with highly aqueous mobile phases.
Pore Size | 175 Å |
---|---|
Carbon Load | 12% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Polar |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 220 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ C4 HPLC Columns
Featuring a lower hydrophobicity than C18 or C8 columns, Thermo Scientific™ Hypersil GOLD™ C4 columns provide outstanding sensitivity and high efficiency.
Pore Size | 175 Å |
---|---|
Carbon Load | 5% |
Stationary Phase | C4 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 220 m²/g |
USP Type | L26 |
Thermo Scientific™ HyPURITY™ C8 HPLC Columns, 5μm Particle Size
Thermo ScientificTM HyPURITYTM C8 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 190 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 8% |
Stationary Phase | C8 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 200 m²/g |
USP Type | L7 |
Thermo Scientific™ HyPURITY™ AQUASTAR™ HPLC Columns, 5μm Particle Size
Thermo ScientificTM HyPURITYTM AquastarTM HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 190 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 10% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 200 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
MilliporeSigma Purospher™ STAR RP-18 Endcapped (2 μm) Capillary Column, 0.3 mm I.D.
Ultra-pure silica (99.999%) for excellent peak symmetry.
Particle Size | 2 μm |
---|---|
Phase | Reversed Phase |
Diameter (Metric) | 0.3 mm |
Material | Stainless Steel |
MilliporeSigma BIOshell A160 Peptide PCS-C18 HPLC Column
BIOshell™ A160 Peptide PCS-C18 columns are specifically engineered to provide efficient separation of peptides as well as small proteins.
Pore Size | 160 Å |
---|---|
Particle Size | 2.7 μm |
Type | HPLC Column |
Phase | Positively Charged Surface (PCS) |
Material | Stainless Steel |
Technique | HPLC |
MilliporeSigma Ascentis™ Express PCS-C18 HPLC Column
Ascentis™ Express PCS-C18 columns are specifically engineered to provide efficient separation of basic, acidic, or neutral compounds under low ionic strength (formic acid) mobile phase conditions.
Pore Size | 90 Å |
---|---|
Particle Size | 2.7 μm |
Type | HPLC Column |
Phase | Positively Charged Surface (PCS) |
Material | Stainless Steel |
Technique | HPLC |
Thermo Scientific™ Hypersil GOLD™ Peptide HPLC Column
Hypersil GOLD™ Peptide performance is assured by our dual quality confirmation, which is performed on both neutrals compounds as well as on a Cytochrome C digest.
Pore Size | 175 Å |
---|---|
Temperature | 60°C |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | Reversed Phase |
Quantity | 1 Each |
Material | Silica |
For Use With (Application) | Peptide |
Surface Area | 220 m²/g |
Type | Analytical Column |
Carbon Load | 11% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 2.1 mm |
pH | 2 to 11 |
Technique | Reversed Phase HPLC |
Particle Shape | 1.9 μm |
Product Line | Hypersil GOLD |
USP Type | L1 |
Thermo Scientific™ Syncronis™ aQ C18 Polar Endcapped HPLC Columns
Use for predictable HPLC separations of compounds in highly aqueous mobile phases.
Thermo Scientific™ Hypersil™ Phenyl-2 HPLC Columns
Use as a general-purpose column with aromatic selectivity with low silanol binding.
Pore Size | 120 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 5% |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Product Line | Hypersil Classical |
USP Type | L11 |
Thermo Scientific™ POROS™ GoPure™ 50 HQ Pre-packed Column, 0.5 x 5 cm, 1 mL
Thermo Scientific™ POROS™ GoPure™ 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange resins or for small scale purification.