HPLC Columns
- (4)
- (1)
- (20)
- (8)
- (3)
- (5)
- (5)
- (17)
- (6)
- (1)
- (6)
- (2)
- (1)
- (381)
- (1)
- (6)
- (306)
- (12)
- (4)
- (1)
- (3)
- (1)
- (163)
- (203)
- (2,034)
- (2)
- (2)
- (161)
- (1)
- (1)
- (83)
- (30)
- (9)
- (80)
- (3)
- (1,472)
- (6)
- (2)
- (32)
- (303)
- (13)
- (4)
- (437)
- (16)
- (2,197)
- (2)
- (1)
- (1)
- (1)
- (7)
- (1)
- (179)
- (7)
- (84)
- (2)
- (9)
- (4)
- (38)
- (9)
- (116)
- (25)
- (1)
- (1)
- (9)
- (10)
- (11)
- (5)
- (323)
- (228)
- (1)
- (1,400)
- (3)
- (7)
- (1)
- (1)
- (143)
- (469)
- (1,533)
- (1)
- (55)
- (1)
- (165)
- (53)
- (1)
- (350)
- (25)
- (988)
- (114)
- (1)
- (21)
- (101)
- (1)
- (483)
- (28)
- (2)
- (3)
- (10)
- (4)
- (2)
- (10)
- (17)
- (2)
- (248)
- (56)
- (1)
- (1,287)
- (16)
- (1)
- (12)
- (15)
- (2)
- (3)
- (130)
- (1)
- (200)
- (4)
- (16)
- (2)
- (3)
- (5)
- (363)
- (14)
- (6)
- (163)
- (10)
- (5)
- (89)
- (614)
- (25)
- (2)
- (43)
- (10)
- (3)
- (14)
- (167)
- (29)
- (15)
- (12)
- (443)
- (138)
- (464)
- (62)
- (8)
- (1,197)
- (30)
- (514)
- (15)
- (2)
- (96)
- (24)
- (3,707)
- (3)
- (10)
- (34)
- (2)
- (25)
- (3)
- (21)
- (30)
- (4)
- (5)
- (4)
- (1)
- (1)
- (4)
- (2,166)
- (1)
- (2)
- (10)
- (482)
- (1)
- (2)
- (20)
- (1)
- (670)
- (258)
- (1,481)
- (1)
- (4)
- (21)
- (3)
- (147)
- (245)
- (5)
- (144)
- (3)
- (13)
- (136)
- (441)
- (49)
- (124)
- (6)
- (75)
- (54)
- (3)
- (67)
- (5)
- (294)
- (2)
- (30)
- (18)
- (34)
- (9)
- (5)
- (3)
- (110)
- (3)
- (2)
- (1)
- (1)
- (5)
- (172)
- (1)
- (1)
- (629)
- (1)
- (8)
- (22)
- (90)
- (6)
- (11)
- (10)
- (2)
- (56)
- (31)
- (21)
- (413)
- (41)
- (156)
- (34)
- (24)
- (129)
- (12)
- (2)
- (2)
- (13)
- (179)
- (114)
- (11)
- (1)
- (313)
- (2)
- (8)
- (7)
- (3,787)
- (124)
- (14)
- (3)
- (1)
- (10)
- (7)
- (4)
- (36)
- (1)
- (83)
- (31)
- (2)
- (11)
- (5)
- (163)
- (1)
- (6)
- (9)
- (1)
- (9)
Filtered Search Results
Hamilton™ PRP-X100 Anion Exchange HPLC Columns: Stainless Steel
Polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-X100 |
| Temperature | 5°C to 60°C |
| Phase | Ion Exchange |
| Product Type | Column |
| Packing Material | PSDVB/Trimethylammonium |
| Column Type | Ion Exchange |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L47 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 5um Particle Size
Stable alternative to C8 or C18 Columns
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PSDVB (Polystyrene Divinylbenzene) |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| For Use With | Organic Compounds, Pharmaceuticals, Steroids, Nucleic Acids, Vitamins, Herbicides |
| Column Type | Reversed Phase |
| Max. Pressure | 5000 psi (345 bar) |
| Column Format | Analytical Column |
| Particle Size | 5 μm |
| Product Type | Column |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Film Thickness | 5 μm |
| USP Type | L21 |
Hamilton™ PRP™-X400 Cation Exchange HPLC Columns
Analyze glyphosate and its metabolite in drinking water. The PRP-X400 provides unique hydrophilic interaction separations.
| Particle Size | 7 μm |
|---|---|
| Stationary Phase | PRP-X400 |
| Length (Metric) | 250 mm |
| Product Type | Column |
| Endcapped | No |
| Packing Material | PSDVB/Sulfonic Acid |
| Mobile Phase Compatibility | 0 to 100% Aqueous, organic modifier |
| pH | 1 to 13 |
| Max. Pressure | 5000 psi |
Hamilton™ PRP™-X200 Cation Exchange Columns
Analyze inorganic and organic cations using conductivity or UV detection. Separate mono or divalent cations depending on mobile phase conditions from 20 ppb to 200 ppm.
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-X200 |
| Temperature | 5°C to 60°C |
| Phase | Ion Exchange |
| For Use With | Analyzing Inorganic and Organic Cations Using Conductivity or UV Detection |
| Column Type | Ion Exchange |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| Column Format | Analytical Column |
| Particle Size | 10 μm |
| Flow Rate | 2 mL/min |
| Product Type | Column |
| Packing Material | PSDVB/Sulfonic Acid |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| Diameter (Metric) | 4.1 mm |
| pH | 1 to 13 |
| USP Type | L22 |
Hamilton™ PRP™-X300 Ion Exclusion HPLC Columns
Polymeric column packing for the separation of alcohols and organic acids
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-X300 |
| Temperature | 5°C to 60°C |
| Phase | Ion Exchange |
| Column Type | Ion Exchange |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| Column Format | Analytical Column |
| Particle Size | 7 μm |
| Product Type | Column |
| Packing Material | PSDVB/Sulfonic Acid |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| Diameter (Metric) | 4.1 mm |
| pH | 1 to 13 |
| USP Type | L17 |
Hamilton™ PRP-1 Reversed Phase HPLC Columns, 10um Particle Size: Stainless Steel
Stable alternative to C8 or C18 Columns
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-1 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| Product Type | Column |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Column Type | Reversed Phase |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L21 |
| Column Format | Analytical Column |
Hamilton™ PRP™-C18 Reversed-Phase HPLC Columns: Stainless Steel
Designed to provide high-efficiency, reversed-phase separations over an extended column life in nearly any mobile phase or pH
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-C18 |
| Phase | Reversed Phase |
| For Use With | LC/MS Separation |
| Product Type | Column |
| Column Type | Reversed Phase |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| Material | Stainless Steel |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L21 |
Hamilton™ PRP™-C18 Reversed-Phase HPLC Columns: PEEK
Designed to provide high-efficiency, reversed-phase separations over an extended column life in nearly any mobile phase or pH
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-C18 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| For Use With | LC/MS Separation |
| Column Type | Reversed Phase |
| Material | PEEK |
| Max. Pressure | 5000 psi (345 bar) |
| Particle Size | 5 μm |
| Product Type | Column |
| Packing Material | Polymer |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Film Thickness | 5 μm |
| USP Type | L21 |
Hamilton™ PRP-X100 Anion Exchange HPLC Columns: PEEK
Polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm
| Pore Size | 100 Å |
|---|---|
| Stationary Phase | PRP-X100 |
| Temperature | 5°C to 60°C |
| Phase | Ion Exchange |
| For Use With | Analysis of Fluoride, Carbonate, Chloride, Nitrite, Bromide, Nitrate, Phosphate, Sulfate and Other Ions |
| Product Type | Column |
| Packing Material | PSDVB/Trimethylammonium |
| Column Type | Ion Exchange |
| Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
| pH | 1 to 13 |
| Material | PEEK |
| Max. Pressure | 5000 psi (345 bar) |
Hamilton™ PRP™-3 Reversed Phase HPLC Columns
PRP-3 polymeric 300 Å columns for gradient separations of peptides and proteins
| Pore Size | 300 Å |
|---|---|
| Particle Size | 10 μm |
| Stationary Phase | PRP-3 |
| Temperature | 5°C to 85°C |
| Phase | Reversed Phase |
| Packing Material | PSDVB (Polystyrene Divinylbenzene) |
| Column Type | Reversed Phase |
| pH | 1 to 13 |
| Max. Pressure | 5000 psi (345 bar) |
| USP Type | L21 |
Restek™ Ultra HPLC Columns with C18 Column Packing, 5um Particle Size
Similar in pore size to Pinnacle II™ columns, but with greater retention
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | 100 Å |
|---|---|
| Particle Size | 5 μm |
| Ligand Type | Monomeric C18 |
| Carbon Load | 20% |
| Stationary Phase | C18 |
| Temperature | 80°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2.5 to 8 |
| Particle Shape | Spherical |
| USP Type | L1 |
Restek™ Raptor™ ARC-18 LC Columns, Particle Size: 5 μm
Ideal for high-throughput LC-MS/MS applications with minimal sample preparation
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | 90 Å |
|---|---|
| Particle Size | 5 μm |
| Ligand Type | Sterically Protected C18 |
| Carbon Load | 5% |
| Stationary Phase | C18, Octadecylsilane |
| Temperature | Max: 80°C |
| For Use With | LC-MS/MS |
| Endcapped | No |
| Packing Material | Superficially Porous Silica (SPP or Core-Shell) |
| pH | 1 to 8 |
| Surface Area | 100 m2/g |
| Max. Pressure | 400 bar (5,800 psi) |
| USP Type | L1 |
Waters Corporation BioResolve RP mAb Polyphenyl Column with Intact mAb and mAb Subunit Standards
BioResolve RP mAb Columns contain superficially-porous-silica particles having an average pore diameter of 450 Å.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | 450 Å |
|---|---|
| Particle Size | 2.7 μm |
| Product Type | Column |
| Quantity | 1/Ea. |
Waters Corporation ACQUITY CSH C18 Column
ACQUITY CSH C18 columns were designed to provide alternate selectivity compared to other reversed-phase UPLC columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
| Pore Size | 130 Å |
|---|---|
| Particle Size | 1.7 μm |
| Product Type | Column |
| Endcapped | Yes |
| Particle Shape | Spherical |
| Max. Pressure | 18000 psi (1240 Bar) |
| USP Type | L1 |