Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium-ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium-ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Mettler Toledo™ InLab™ 605-ISM Dissolved Oxygen Sensors
For use with the SevenExcellence™ bench meter and the SevenGo Pro™ portable instrument.
Labconco™ Inflow and Downflow Sensor Kit
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Allows display of inflow and downflow velocities on the LCD information center on MyLogic™ Digital Display.
MilliporeSigma™ Supelco™ Tedlar™ SCV Gas Sampling Bag with Thermogreen™ LB-2 Septa
Tedlar™ is recommended in several US EPA methods for sampling VOCs and sulfur compounds.
Includes | Screw Cap Valve (SCV) |
---|---|
Material | PVDF Film |
Product Line | Tedlar |
MilliporeSigma™ Supelco™ Tedlar™ PLV Gas Sampling Bag with Thermogreen™ LB-2 Septa
Tedlar™ is recommended in several US EPA methods for sampling VOCs and sulfur compounds.
Includes | Push/Pull Lock Valve (PLV) |
---|---|
Material | PVDF Film |
Product Line | Tedlar |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only (No Probes)
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium-ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Labconco™ Oxygen Monitor, 0.1 to 100%
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Measures percent of oxygen inside the glove box using a chemical-resistant electrochemical sensor
Includes | 10 ft. of interconnecting sensor cable, power cord for connection to the glove box's interior electrical receptacle and mounting bracket for hanging from Interior Shelves (5061600, sold separately) or Rear Interior Shelf Kit (5235000, sold separately) |
---|---|
Flow Rate | 0 to 10 L/min. |
Gases Measured | Oxygen |
Display Type | LCD |
Temperature (English) Operating | 68 to 77°F |
Product Type | Oxygen Monitor |
For Use With (Equipment) | Glove Boxes |
Response Time | 15 sec. (1 sec. average time) |
Zero Noise | Yes |
Detectable Analytes | Oxygen |
Frequency | 50/60 Hz |
Temperature (Metric) Operating | 20 to 25°C |
Inputs | Gas |
MilliporeSigma™ Supelco™ Tedlar™ Gas Sampling Bag for EPA TCLP Method
Tedlar™ is recommended in several US EPA methods for sampling VOCs and sulfur compounds.
Supel™-Inert Multi-Layer Foil Gas Sampling Bags, Sold by MilliporeSigma™ Supelco™
Ideal for sampling low molecular weight compounds. Two outer layers of aluminum film provide a great barrier to gases permeating through the walls of the bag.
Description | Chemically Inert with Light/Moisture Protection |
---|---|
Port Detail | Thermogreen™ LB-2 Septa |
Resistant To | Chemicals |
No. per Pack | 10 |
Certifications/Compliance | NIOSH 6603, OSHA ID-172 (ID-210) |
For Use With (Application) | Sampling Low Molecular Weight Compounds Such as Carbon Monoxide (CO), Carbon Dioxide (CO2) and Permanent Gases. Also Suitable for Sampling Sulfur Compounds Such as Hydrogen Sulfide (H2S), Carbon Disulfide (CS2) and Mercaptans. |
Closure Type | Screw Cap Valve (SCV) |
Product Line | Supel™ |
Film Description | Multi-layer foil composed of two outer layers of aluminum film |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium-ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium-ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Velp™ Scientific Denitrification Glass Bottle for RESPIROMETRIC Sensor
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Denitrification glass bottle for use with the RESPIROMETRIC Sensor.