Gas and Vapor Detection















Filtered Search Results

Components Measured | Carbon Dioxide |
---|---|
Quantity | 10 |
StatLab™ SafeTech Vapor Monitor
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Vapor monitoring is important to ensure the safety of employees and comply with OSHA guidelines.
Type | Single Gas Detector |
---|---|
For Use With (Equipment) | Laboratory |
Dräger™ accuro™ Bellows Pump: Hardside Kit
Ergonomic design allows easy measurement of more than 350 gases—including formaldehyde
PureAire Monitoring Systems Dual O2/CO2 Monitor
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
PureAire Monitoring Systems Dual O2/CO2 Monitor designed for continuous monitoring in confined spaces
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium-ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium-ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium-ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
MilliporeSigma™ Supelco™ Supel™-Inert Multi-Layer Foil Gas Sampling Bag
Ideal for sampling low molecular weight compounds such as carbon monoxide (CO), carbon dioxide (CO2) and permanent gases
Includes | Push/Pull Lock Valve (PLV) |
---|---|
Quantity | 10/Pk. |
Material | Multi-layer Foil |
Product Line | Supel™ |
MSA™ ALTAIR™ 5X Multigas Detector
Monitors up to six gases simultaneously — ideal for confined space monitoring
Height (Metric) | 9.53 cm |
---|---|
Warranty | 3 Years |
Width (English) | 3.8 in. |
Length (Metric) | 8.89 cm |
Length (English) | 3.5 in. |
Width (Metric) | 9.65 cm |
Components Measured | LEL,Oxygen,Carbon Monoxide,Hydrogen Sulfide |
Alarm Types | Audible, visual, vibrating |
Dimensions (L x W x H) | 3.5 x 3.8 x 3.75 in. (8.89 x 9.65 x 9.53cm) |
Battery Life | 20 hr. |
IP Rating | 65 |
Temperature Range (English) | -4°F to +122°F |
Weight (English) | 27.84 oz. |
Temperature Range (Metric) | -20°C to +50°C |
Weight (Metric) | 790g |
Height (English) | 3.75 in. |
MSA™ ALTAIR™ Pro Single-Gas Detectors (Alternate Setpoint Models)
Provides worry-free performance and stands up to the roughest handling in even the toughest industrial environments
Height (Metric) | 2.54 cm |
---|---|
Warranty | 2 Years |
Width (English) | 2 in. |
Length (Metric) | 8.63 cm |
Length (English) | 3.4 in. |
Humidity Range | 10 to 95% |
Width (Metric) | 5.08 cm |
Alarm Types | Audible, visual, vibrating |
Dimensions (L x W x H) | 3.4 x 2 x 1 in. (8.63 x 5.08 x 2.54cm) |
IP Rating | 67 |
Temperature Range (English) | -4°F to +122°F |
Weight (English) | 4 oz. |
Temperature Range (Metric) | -20°C to +50°C |
Weight (Metric) | 113g |
Height (English) | 1 in. |
Dräger™ X-am™ 2500 Multi-Gas Detection
Instrument provides personal protection in industrial, mining, refinery, and confined space applications. Lightweight and easy to operate, it shows all readings at once on the large LCD and stores peak values, which are easily reset.