Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium Ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium Ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
MSA™ ALTAIR™ 5X Multigas Detector
Monitors up to six gases simultaneously — ideal for confined space monitoring
Height (Metric) | 9.53 cm |
---|---|
Warranty | 3 Years |
Width (English) | 3.8 in. |
Length (Metric) | 8.89 cm |
Length (English) | 3.5 in. |
Width (Metric) | 9.65 cm |
Components Measured | LEL,Oxygen,Carbon Monoxide,Hydrogen Sulfide |
Alarm Types | Audible, visual, vibrating |
Dimensions (L x W x H) | 3.5 x 3.8 x 3.75 in. (8.89 x 9.65 x 9.53cm) |
Battery Life | 20 hr. |
IP Rating | 65 |
Temperature Range (English) | -4°F to +122°F |
Weight (English) | 27.84 oz. |
Temperature Range (Metric) | -20°C to +50°C |
Weight (Metric) | 790g |
Height (English) | 3.75 in. |
Depth (English) | 1 in. |
---|---|
Width (English) | 2.125 in. |
Length (Metric) | 89 mm |
Color | Charcoal Gray |
Length (English) | 3.5 in. |
Humidity Range | 10 to 95% RH (non-condensing) |
For Use With (Application) | Ideal for use in Confined Space, Toxic Detection applications |
Width (Metric) | 54 mm |
Battery Type | Lithium |
Alarm Types | Visual, Audible and vibrating |
Battery Life | 18 Months |
Display Type | Backlit LCD |
IP Rating | IP67 |
For Use With (Equipment) | MSA GALAXY GX2 Automated Test System and MSA Link Pro software |
Depth (Metric) | 25 mm |
Weight (English) | 4 oz. |
Certifications/Compliance | cCSAus Class I Div 1 Groups A, B, C, D; Class II Div 1 Groups E, F, G Class III; Tamb: -40C to +60C T4; USA: UL 913 7th Edition; Canada: CSA 22.2 No. 157 |
Temperature Range (Metric) | -10° to +40°C |
Weight (Metric) | 113g |
Honeywell Analytics™ GasAlertMax XT II Confined Space Kit
Contains the easy to use GasAlertMax XT II multi-gas detector along with important tools and materials for calibration and gas sampling
Honeywell BW™ MicroClip XL, %LEL, O2, H2S, CO
Honeywell BW™ GasAlertMicroClip provides affordable protection from atmospheric gas hazards and extended battery life, especially in cold weather.
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium Ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Sampling Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium Ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - FID Only with Enhanced & Sampling Probes
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Detection Limits | 0.5 ppm of methane |
Width (Metric) | 22.9 cm |
Detector Type | Flame Ionization Detector (FID) |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | 0 to 30,000 ppm (methane) |
Battery Type | Lithium Ion |
Repeatability | ±2% at 500 ppm of methane |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
Thermo Scientific™ TVA2020 Toxic Vapor Analyzer - Dual FID/PID with Enhanced Probe
Quickly detect organic and inorganic compounds in demanding applications such as Method 21 monitoring and site remediation.
Width (English) | 9 in. |
---|---|
Response Time | FID: Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane; PID: Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene |
Detection Limits | FID: 0.5 ppm of methane; PID: 0.5 ppm of isobutylene |
Width (Metric) | 22.9 cm |
Detector Type | Dual Configured with FID and PID |
Flow Rate | 1 L/min., nominal at sample probe inlet |
Components Measured | Most Organic and Inorganic Compounds |
Accuracy | FID Instrument - ±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm; PID Instrument - ±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hours at 0°C |
Voltage | 120 V |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable; VOC or FE Mode - 2 to 30 seconds, user selectable |
Certifications/Compliance | USA: Class I, Division 1, Groups A,B,C,D T3; Canada: Class I, Zone 1, Ex db ib IIC T3 Gb; ATEX: CE0359 Ex II 2 G Ex db ib IIC T3 Gb; IECEx: Ex db ib IIC T3 Gb |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Warranty | One year from date of shipment |
Depth (English) | 4 in. |
Concentration | FID: 0 to 30,000 ppm (methane); PID: 0 to 2000 ppm (isobutylene) |
Battery Type | Lithium Ion |
Repeatability | FID: ±2% at 500 ppm of methane; PID: ±1% at 100 ppm of isobutylene |
Serial Interface | USB |
Computer Requirements | USB port, Windows XP operating system or higher |
Depth (Metric) | 10.2 cm |
Fuel | 99.99% H2 for FID |
Temperature Range (English) | 14°F to 113°F |
Frequency | 50/60 Hz |
Portable Operation Time | Minimum 10 hours |
Temperature Range (Metric) | -10°C to 45°C |
MSA™ ALTAIR™ 4XR Multigas Detector
Provides real-time incident awareness when paired with the ALTAIRALTAIR™ Connect app via a Bluetooth™ wireless connection. MSA™ ALTAIR™ 4XR Multigas Detector is the toughest 4-gas monitor when outfitted with rapid-response XCell™ sensors.
Honeywell BW™ Clip Multi-Gas Portable Gas Detector
BW™ Clip Multi-Gas Portable Gas Detector is a low maintenance multi-gas detector that requires no charging and no battery or sensor servicing.
Alarm Types | Audible, visual, vibrating |
---|---|
Battery Life | 14 hr. |
Temperature Range (English) | -4°F to +122°F |
Weight (English) | 11.92 oz. |
Humidity Range | 10 to 100% |
Temperature Range (Metric) | -20°C to +50°C |
Battery Type | Alkaline |
Weight (Metric) | 338g |
Honeywell Analytics™ GasAlertMax XT II Multigas Detectors
Monitor up to four hazardous gases with a robust, motorized pump for intelligent, remote sampling. The GasAlertMax XT II Multigas Detector is compact, comfortable, field tough, and ideal for confined sampling.
Height (Metric) | 13 cm |
---|---|
Alarm Types | Audible, visual, vibrating |
Depth (English) | 2 in. |
Width (English) | 2.8 in. |
Display Type | LCD |
Depth (Metric) | 5.08 cm |
Temperature Range (English) | -4°F to +122°F |
Weight (English) | 11.1 oz. |
Humidity Range | 10 to 100% |
Temperature Range (Metric) | -20°C to +50°C |
Width (Metric) | 7.2 cm |
Weight (Metric) | 316g |
Height (English) | 5.12 in. |