pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
Thermo Scientific™ Orion™ Surfactant Half Cell Ion Selective Electrode
Conduct end point detection in titrations of anionic or cationic surfactants in a solution with the Thermo Scientific™ Orion™ Surfactant Half-Cell.
Thermo Scientific™ Orion Star T900 Series Titrator Accessories
Minimize maintenance downtime with easy to install Orion Star T900 series titrator replacement parts. Orion Star T900 series titrator accessories expand functionality.
| For Use With (Equipment) | Orion Star T910 pH titrator, Orion Star T920 redox titrator, Orion Star T930 ion titrator, Orion Star T940 all-in-one titrator |
|---|
Thermo Scientific™ Orion™ Chloride Ion Selective Electrodes
Easily and reliably analyze free chloride ions in aqueous solutions. Provides quick, accurate and economical measurements.
| Type | Combination ISE |
|---|---|
| For Use With (Equipment) | Chloride electrodes can be used on any ISE meter with a BNC connection The electrodes can also be used on meters with a variety of inputs when an adapter cable is used. |
Thermo Scientific™ Orion™ ROSS™ Sodium Ion Selective Electrodes
Measure sodium ions in aqueous solution quickly, accurately and economically.
| Diameter (English) Body | 0.47 in |
|---|---|
| Length (Metric) Cable | 1 M |
| Length (Metric) | 120 mm |
| For Use With (Equipment) | ISE Meter |
| Temperature (English) Operating | 32 to 176°F |
| Operating Range (Metric) | Saturated to 10-6 M, saturated to 0.02ppm |
| Length (English) | 4.72 in |
| Length (English) Cable | 39.3 in. |
| Material | Glass |
| Filling Solution Type | 900010 for regular Na+ (> 10-5 M or 0.2 ppm), 900012 for low level Na+ (< 10-5 M or 0.2 ppm) |
| Temperature (Metric) Operating | 0°C to 100°C |
| Measurement Range |
|
Thermo Scientific™ Orion™ ROSS Ultra™ Thin Stem Glass Bodied Combination pH Electrode
Top-performance, semi-micro pH electrodes to measure samples as small as 0.2 mL
Thermo Scientific™ Orion Star T940 All-in-One Titrator and Kits
Benefit from the integration of our core electrochemistry technology with a state-of-the-art dispensing system to create an automated all-in-one titrator, a modern, simplified automated system designed to help make performing titrations easier, more reliable and more reproducible than manual titrations.
| Titration Technique | Equivalence point or preset endpoint |
|---|---|
| Memory | Non-volatile memory preserves data logs and settings |
| Advanced ISE Functions | Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette |
| Resolution (pH) | 0.001, 0.01, 0.1 (user selectable) |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish |
| Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
| Cycles Per Titration Run | 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations |
| Data Management Details | Data log export as CSV or PDF file, short or long format |
| Display Type | 5.7 in. color capacitive touchscreen, 640 x 480 resolution |
| Functions Available | Sample titration, titrant standardization, calibration and direct measure |
| Resolution (mV) | 0.1 mV |
| Data Points | 100 data sets each: sample titration, titrant standardization, calibration and direct measure |
| Temperature Probe Calibration | Optional 1 point offset calibration |
| Certifications/Compliance | CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010 |
| Probe Type | pH electrode, redox electrode or ion selective electrode (ISE); reference half-cell electrode; ATC temperature probe; stirrer probe |
| Accuracy (mV) | ±0.2 mV |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading, whichever is greater |
| Titrant Determination | Standardization titration or manual concentration input |
| Warranty | 1 year replacement warranty |
| Calibration Points (ISE) | 1 to 5 |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Dimensions (L x W x H) | 10 x 16 x 14 in. (25.4 x 40.6 x 35.6 cm) |
| Temperature Selection | Manual or automatic |
| Precision | 0.5% RSD, dependent on environment and handling conditions |
| Outputs | 3 USB ports for printer, USB flash drive and computer software connections |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes, adjustable |
| Range (mV) | -2000.0 to +2000.0 mV |
| Methods | Up to 10 methods with optional password protection; import/export methods via USB flash drive |
| Resolution | Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) |
| Titration Process Control | Routine, quick, careful or user defined |
| Time and Date | Yes, with nonvolatile battery backup |
| Updateable Firmware | Yes, using USB flash drive |
| Range (pH) | -2 to 20 |
| For Use With (Application) | Acid-base titrations, redox titrations, ion concentration titrations |
| Titration Types | Direct or back titration |
| Channels | 1 |
| Accuracy (pH) | ±0.002pH |
| Range (ISE) | 0.0001 to 19990 |
| Titration Setup Wizard | Yes, using Start a New Titration workflow |
| Stirrer Probe Speeds | 5 user selectable speeds (250 to 3700 RPM) |
| Burette Sizes | 10 mL, 20 mL (included) or 50 mL |
| Burette Functions | Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc |
| Inputs | BNC (pH, redox or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
| Accuracy (Temperature) | ±0.2 °C |
| Equivalence Points | 1 to 2 |
| Electrical Requirements | 100-240V, 50/60 Hz |
| Temperature (English) Operating | 41°F to 104°F |
| Preset Endpoints | 1 to 3 |
| Material | ABS Plastic |
| Calibration | pH, mV, ion concentration (ISE) and temperature |
| Calibration Points | 1 point relative mV (RmV) mode |
| Alarm Output | Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder |
| IP Rating | IP51 |
| Model | Orion Star T940 |
| Sample ID | Auto-incremental, manual or off |
| Resolution (Temperature) | 0.1 °C |
| Temperature Range (Metric) | -5.0°C to +100.0°C |
| Temperature (Metric) Operating | 5°C to 40°C |
| Blank Options | Fixed value or variable value using titration |
Thermo Scientific™ Orion™ Single Junction Refillable Epoxy Bodied Combination pH Electrode
Confidently maneuver and measure in the field or on the plant floor with Orion™ refillable epoxy body electrodes.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 194°F |
| Precision | 0.02 |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Length (English) | 4.7 in. |
| Filling Solution Type | 4M KCl with Ag/AgCl |
| Material | Epoxy Body |
| Junction | Glass Fiber |
| Diameter (Metric) Body | 12 mm |
| Temperature (Metric) Operating | 0°C to 90°C |
| Internal Reference | Ag/AgCl |
Thermo Scientific™ Orion™ High Performance Ammonia Combination Ion Selective Electrode
Obtain quick, simple, accurate and economical results at low level ammonia measurements.
Thermo Scientific™ Orion Star™ A321 pH Portable Meter PROMO
Accurately monitor pH, mV, ORP and temperature with our waterproof, portable pH meter for high performance in challenging field locations.
Thermo Scientific™ Orion Star™ A325 pH/Conductivity Portable Multiparameter Meter
Accurately measure pH, conductivity and temperature with our pH/conductivity portable meter for high performance in challenging field tests.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 2 |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Model | Orion Star A325 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ ROSS Ultra™ Refillable Epoxy Bodied pH/ATC Triode™
Accurately measure pH and temperature together in just one electrode, with a built-in temperature sensor.
| Type | pH/ATC Combination Electrode |
|---|---|
| Warranty | 2 Years |
| Length (Metric) | 120 mm |
| Precision | 0.01 |
| Isopotential Point | 7 |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Filling Solution Type | ROSS electrode 3 M KCl fill solution (Cat. No. 810007) |
| Material | Epoxy Body |
| Junction | Glass Fiber |
| pH Relative Accuracy | 0.03 pH for buffers using automatic temperature compensation |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion Star™ A123 Dissolved Oxygen Portable Meter
Take simple dissolved oxygen and temperature measurements with this portable meter with easy operation for basic field testing.
| Temperature (Metric) Range | 0.0°C to 50.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 450 to 850mmHg (manual entry) |
| Memory | Non-volatile memory preserves log and settings |
| Languages | English |
| Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Channels | 1 |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 450 to 850mmHg, automatic with manual entry |
| Battery Life | 2000 hours |
| Data Management Details | Internal data point memory |
| Display Type | LCD |
| Data Points | 50 |
| Calibration Modes | Water-saturated air, manual (Winkler titration) |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Inputs | 9 pin MiniDIN (polarographic DO sensor with built-in temperature) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.5 kg |
| Salinity Factor | 0 to 45 ppt, automatic correction using manual entry of sample salinity |
| Stability | Smart Stability and Smart Averaging |
| Warranty | 3 Year Meter Warranty |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Sensor Types | Polarographic Dissolved Oxygen Sensor |
| Percent Saturation Range Polarographic DO | 0.0 to 200.0 % saturation |
| Log Function Type | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Mode |
| Battery Type | Four AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
| IP Rating | IP-67 |
| Temperature Selection | Automatic with ATC temperature probe |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Keypad | Simple with highlighted measure key, scroll and shortcut keys |
| Outputs | None |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Range (Polarographic DO) | 0.00 to 20.00 mg/L |
| Percent Saturation Range (Polarographic DO) | 0.0 to 200.0 % saturation |
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop Meter Kit with pH and Conductivity Modules PROMO
The Thermo Scientific™ Orion VERSA STAR pH/Conductivity Multiparameter Benchtop Meter is your meter as you need it — for now and later.
Thermo Scientific™ Orion™ Double Junction Semi-Micro Stem Glass Bodied Combination pH Electrode
Top-performance, semi-micro pH electrodes to measure samples as small as 0.2 mL.
Thermo Scientific™ Orion™ Calcium Ion Selective Electrodes
Measure calcium ions in aqueous solutions simply, accurately and economically.