pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
METTLER TOLEDO™ InLab™ Versatile pH Electrode Replaceable Junction Tool
Tool consisting of two parts to replace ceramic junctions on InLab™ Versatile and InLab™ Versatile Pro.
METTLER TOLEDO™ EasyPlus Easy Pro Titrator
Combines acid/base equivalence point, pH endpoint, and precipitation/redox indicative titrations on one instrument. Simple titrations of juice, wine, free fatty acids in food, chloride in food, and sulfides in oils, and more are all easily performed with the EasyPro titrator.
Thermo Scientific™ Orion™ ROSS™ Glass Bodied Combination pH Electrode
Capture accurate measurements of a variety of sample types, including solvents, with Thermo Scientific™ Orion™ glass body pH electrodes.
| Length (Metric) Cable | 1 m |
|---|---|
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 212°F |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Length (English) | 4.72 in. |
| Material | Glass Body |
| Storage Requirements | Short-term Storage (up to one week): Soak the electrode in ROSS' pH electrode storage solution, Cat. No. 810001, or standard pH electrode storage solution, Cat. No. 910001. For enhanced electrode performance, use ROSS' pH electrode storage solution. Long-term Storage (more than one week): Fill the reference chamber and securely cover the fill hole. Cover the sensing bulb and reference junction with the protective cap, sleeve or storage bottle containing a few drops of storage solution. Before returning the electrode to use, prepare it as a new electrode. |
| Diameter (English) Body | 0.47 in. |
| Includes | One 60mL bottle of Orion ROSS filling solution and spout cap |
| Precision | 0.01 |
| Length (English) Cable | 39.37 in. |
| Filling Solution Type | 3M KCl |
| Drift | <0.002 pH/day |
| Junction | Ceramic |
| Diameter (Metric) Body | 12 mm |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Mettler Toledo™ FiveGo™ F2 pH/mV Meters
Portable meter provides reliable and high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | 200 measurements, current calibration |
| Log Function Type | Automatic, Manual |
| Measurement Modes | pH |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Calibration Points | 3 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 18.8 x 7.7 x 3.3 cm (97.4 x 3 x 1.3 in.) |
| Display Type | LCD |
| Model | F2 |
| Resolution (mV) | 1mV |
| Data Points | 200 |
| Backlight Option | None |
| Weight (English) | 0.5 lb. |
| Resolution (Temperature) | 0.1° |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | -1999 to 1999 |
| Inputs | BNC, Cinch |
| Accuracy (Temperature) | ±0.5°C |
| Weight (Metric) | 0.26 kg |
BUCHI pH Electrode Gel
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with KjelMaster K-375.
Thermo Scientific™ Orion™ Pro Star MP218 pH/ion, Conductivity and DO Bench Meter
Designed to provide accurate and reliable pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO, barometric pressure and temperature analysis, the Thermo Scientific™ Orion™ Pro Star MP218 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Resolution (Polarographic DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Pressure Range | 400.0 to 850.0 mmHg; 0.533 to 1.133 bar |
| Range (Resistivity) | 1.0Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Advanced ISE Functions | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Measurement Modes | pH,ORP,mV,Ion Concentration (ISE),Conductivity,Dissolved Oxygen (mg/L),Temperature,Barometric Pressure |
| Barometric Pressure Correction | Yes, automatic with built-in barometer or manual |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Resolution (mV) | 0.1 mV |
| Resolution (Ion) | 0.0001 minimum, 1 to 5 digits |
| Data Points | 10,000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or custom concentration value (Winkler) |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Probe Type | Polarographic or optical DO electrode |
| Salinity Factor | 0.0 to 50.0 ppt; automatic with conductivity measurement or manual entry |
| Accuracy (mV) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Warranty | 2 year meter warranty |
| Temperature Accuracy | ±0.3°C, ±0.5°F |
| Calibration Points (ISE) | Up to 5 |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Range (RDO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Percent Saturation Range (RDO) | 0.0 to 600.0% saturation |
| Keypad | Capacitive touchscreen user interface |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Temperature Range (English) | -22.0°F to +266.0°F |
| Range (Relative mV) | -2000 to 2000 mV |
| Calibration Points (pH) | 1 to 5 points |
| Backlight Option | Yes |
| Percent Saturation Relative Accuracy (RDO) | ±2% saturation |
| Range (Polarographic DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Range (mV) | -2000 to 2000 mV |
| Accuracy (Barometer) | ±6.0 mmHg; ±0.008 bar |
| Range (ORP) | -2000 to 2000 mV |
| Methods | 10 per channel (30 total) |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Accuracy (pH) | ±0.002 pH |
| Range (ISE) | 0.0001 to 19999 |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Resolution (RDO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
| Accuracy (Conductivity) | ±0.5% reading |
| Resolution (DO) | 0.1, 1% saturation; 0.01, 0.1 mg/L or ppm |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2% saturation |
| Inputs | Channel 1: BNC for pH, ORP or ISE, 8-pin MiniDIN for ATC, pin-tip for reference; Channel 2: 8-pin MiniDIN for conductivity with ATC; Channel 3: 9-pin MiniDIN for dissolved oxygen with ATC |
| Weight (Metric) | 1.00 kg |
| Resolution (ORP) | 0.1 mV |
| Calibration Points (Conductivity) | 1 to 5 points |
| Accuracy (DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Resolution (Resistivity) | 0.1 Ωminimum, auto-ranging |
| Isopotential Point | 7.000 pH; 1.000 ion concentration |
| Accuracy (Polarographic DO) | ±2% saturation; ±0.02 mg/L or ppm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, DO, Barometric Pressure, Temperature |
| Accuracy (ORP) | ±0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 to 5 (pH), 1 (ORP), 1 to 5 (ion), 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (DO), 1 (barometer), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
| Weight (English) | 2.20 lbs. |
| Range (Ion) | 0.0001 to 19999 |
| Temperature Range (Metric) | -30.0°C to +130.0°C |
| Range (DO) | 0.0 to 600.0% saturation; 0.01 to 90.0 mg/L or ppm |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±2% saturation; ±0.02 mg/L or ppm |
Thermo Scientific™ Orion™ Glass Bodied Temperature Probes
Automatically correct pH measurements for variation in electrode slope due to temperature change with this glass ATC probe.
| Diameter (English) Body | 0.3 in. |
|---|---|
| Type | ATC Probe |
| Accuracy | ±1°C |
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 212°F |
| pH Range | 0 to 14 |
| Length (English) | 4.7 in. |
| Material | Glass |
| Storage Requirements | Store in air |
| Diameter (Metric) Body | 8 mm |
| Temperature (Metric) Operating | 0°C to 100°C |
Thermo Scientific™ Orion™ Double Junction Glass Bodied Combination pH Electrode
Capture accurate measurements of a variety of samples types, including solvents, with Orion glass body pH electrodes.
Thermo Scientific™ Elite pH Spear Pocket Testers and Replacement Sensors
Flexible on-the-go pH testing using durable Elite spear pocket testers with replaceable sensors for a variety of applications include food, beverage, agriculture and more!
| Temperature Accuracy | Manual input |
|---|---|
| Temperature Range (English) | 32.0°F to 140.0°F |
| Measurement Modes | pH |
| Range (pH) | -1 to 15 |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | 0.0°C to 60.0°C |
| Accuracy (pH) | ±0.02 |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion Star™ A221 Portable pH Meter
Reliably measure pH, mV, ORP and temperature with our portable pH meter for advanced field analysis and printer or computer interfacing.
Thermo Scientific™ Orion Star™ A326 pH/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, dissolved oxygen and temperature with our pH/DO/RDO portable meter for high performance in challenging field tests.
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
|---|---|
| Pressure Range | 400 to 850mmHg |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature,Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6mmHg |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1mmHg |
| Range (pH) | -2 to 20 |
| Accuracy (pH) | ±0.002 |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Weight (Metric) | 0.5 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A326 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |
Thermo Scientific™ Orion™ ROSS™ Sure-Flow™ Thin Stem Epoxy Bodied Combination pH Electrode
Attain stable, drift-free measurements of challenging samples in narrow containers using a sure-flow electrode with its unique free-flowing liquid-to-liquid junction.
Thermo Scientific™ Orion™ ROSS Ultra™ Epoxy Bodied pH/ATC Triode™
Accurately measure pH and temperature together in just one electrode, with a built-in temperature sensor.
| Type | pH/ATC Combination Electrode |
|---|---|
| Warranty | 18 Months |
| Length (Metric) | 120 mm |
| Precision | 0.01 |
| Isopotential Point | 7 |
| pH Range | 0 to 14 |
| Diameter (Metric) | 12 mm |
| Filling Solution Type | None required |
| Material | Rugged Epoxy Body, Filled with Low Maintenance Gel |
| Junction | Glass Capillary |
| pH Relative Accuracy | 0.03 pH for buffers using automatic temperature compensation |
| Temperature (Metric) Operating | 0°C to 80°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion™ ROSS™ Flat Surface Refillable Epoxy Bodied Combination pH Electrode
Measure flat, soft, moist, semi-solid or small volume samples with epoxy body flat surface pH electrodes.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Temperature (English) Operating | 32°F to 212°F |
| Precision | 0.01 |
| pH Range | 0 to 14 |
| Diameter (Metric) Cap | 16 mm |
| Filling Solution Type | 3M KCl |
| Drift | <0.002pH/day |
| Material | Epoxy Body |
| Junction | Glass Fiber |
| Storage Requirements | Short-term Storage (up to one week): Soak the electrode in ROSS' pH electrode storage solution, Cat. No. 810001, or standard pH electrode storage solution, Cat. No. 910001. For enhanced electrode performance, use ROSS' pH electrode storage solution. Long-term Storage (more than one week): Fill the reference chamber and securely cover the fill hole. Cover the sensing bulb and reference junction with the protective cap, sleeve or storage bottle containing a few drops of storage solution. Before returning the electrode to use, prepare it as a new electrode. |
| Diameter (Metric) Body | 12 mm |
| Temperature (Metric) Operating | 0°C to 100°C |
| Internal Reference | ROSS |
Thermo Scientific™ Orion Star™ A329 pH/ISE/Conductivity/Dissolved Oxygen Portable Multiparameter Meter
Accurately measure pH, ion concentration, conductivity, dissolved oxygen and temperature with our pH/ISE/conductivity/RDO/DO portable meter.
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850mmHg |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Calibration Points (ISE) | 1 to 5 |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | 4 AA (included) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00mg/L |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 5 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00mg/L |
| Range (mV) | ±2000.0 mV |
| Accuracy (Barometer) | ±6mmHg |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1mmHg |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 3 |
| Accuracy (pH) | ±0.002 |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Weight (Metric) | 0.5 kg |
| Calibration Points (Conductivity) | Up to 5 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP67 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Temperature Resolution | 0.1°C, 0.1°F |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |